Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Inductive Power Transfer Link at 13.56 MHz for Leadless Cardiac Pacemakers

View through CrossRef
Inductive power links are most viable for the long-term powering of cardiac pacemakers. Designing an inductive power link without surpassing the specific absorption rate (SAR) for modern leadless cardiac pacemakers (LCPs) remains a challenging task because of its size and implantation depth. The inductive power link employed in the conventional works is either designed at a high frequency or based on the size, shape, weight, and implantation depth of conventional cardiac pacemakers. Here, a 3-coil inductive power transfer link with a circular transmitter coil and solenoidal receiver coil is designed at 13.56 MHz to provide uninterrupted power to the modern LCPs. Considering the food and drug administration approved term for implant size of modern LCP, the receiver coil is designed with 6 mm diameter and 6.5 mm length. The performance of the link has been verified through simulations and measurements under perfect alignment, lateral and/or angular misalignments, and distance variation between the coils. At a 50 mm horizontal distance between transmitter and receiver coils, the transmission coefficient is −30.9 dB. The maximum simulated average SAR at heterogeneous phantom is 0.30 W/kg, which is lower than the limit set by the Federal Communications Commission for radiation threshold exposure. Experiments conducted on pork’s heart verified the reliability of the simulated results. At a 50 mm distance between the coils, the measured transmission coefficient is −34 dB, and at an input power of 1 W, the power delivered to the load is 0.7 mW.
Title: Inductive Power Transfer Link at 13.56 MHz for Leadless Cardiac Pacemakers
Description:
Inductive power links are most viable for the long-term powering of cardiac pacemakers.
Designing an inductive power link without surpassing the specific absorption rate (SAR) for modern leadless cardiac pacemakers (LCPs) remains a challenging task because of its size and implantation depth.
The inductive power link employed in the conventional works is either designed at a high frequency or based on the size, shape, weight, and implantation depth of conventional cardiac pacemakers.
Here, a 3-coil inductive power transfer link with a circular transmitter coil and solenoidal receiver coil is designed at 13.
56 MHz to provide uninterrupted power to the modern LCPs.
Considering the food and drug administration approved term for implant size of modern LCP, the receiver coil is designed with 6 mm diameter and 6.
5 mm length.
The performance of the link has been verified through simulations and measurements under perfect alignment, lateral and/or angular misalignments, and distance variation between the coils.
At a 50 mm horizontal distance between transmitter and receiver coils, the transmission coefficient is −30.
9 dB.
The maximum simulated average SAR at heterogeneous phantom is 0.
30 W/kg, which is lower than the limit set by the Federal Communications Commission for radiation threshold exposure.
Experiments conducted on pork’s heart verified the reliability of the simulated results.
At a 50 mm distance between the coils, the measured transmission coefficient is −34 dB, and at an input power of 1 W, the power delivered to the load is 0.
7 mW.

Related Results

Aveir Leadless Pacemaker implantation in pediatric population: a case series
Aveir Leadless Pacemaker implantation in pediatric population: a case series
Abstract Background While the Medtronic Micra pacemaker provided a small device for leadless pacemaker implantation, the Aveir d...
Leadless Pacemaker tine fracture and dislocation: two case reports
Leadless Pacemaker tine fracture and dislocation: two case reports
Abstract The rate of leadless pacemaker implantation is increasing worldwide. To date, there have been few reports of leadless pacemaker dislocation and extraction. This ar...
/r/philosophy 2016-2017 AMA Series Recap + Survey!
/r/philosophy 2016-2017 AMA Series Recap + Survey!
This past academic year the moderators of /r/philosophy organised an ongoing AMA series with 18 different philosophers working on a variety of different topics, from metaphysics to...
P185 FOLLOW–UP OF PATIENTS UNDERGOING POST–EXTRACTION LEADLESS PACEMAKER IMPLANTATION
P185 FOLLOW–UP OF PATIENTS UNDERGOING POST–EXTRACTION LEADLESS PACEMAKER IMPLANTATION
Abstract Introduction The implantation of traditional stimulation devices involves numerous complications, in the short and long...
Abstract 4367732: Leadless Pacemaker Implantation in the Region of Bachmann’s Bundle: Initial Results
Abstract 4367732: Leadless Pacemaker Implantation in the Region of Bachmann’s Bundle: Initial Results
Background: Leadless pacemakers are an emerging technology offering a less invasive alternative to traditional transvenous systems. Bachmann bundle (BB) pacing ...
Electrophysiology and Indications for Pacing in the ‘8O’s*
Electrophysiology and Indications for Pacing in the ‘8O’s*
Bradycardias originate either from a dysfunction of impulse formation in the sinoatrial node or from a disturbed conduction of the impulse. Different pathogenetic mechanisms are di...
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Background: Cardiac myxomas are benign cardiac neoplasms usually found solitarily located within a single cardiac chamber, most commonly in the left atrium. With no established cau...
Improving outcomes in single chamber leadless pacemakers: strategies for minimizing vascular complications
Improving outcomes in single chamber leadless pacemakers: strategies for minimizing vascular complications
Abstract Background Leadless pacemaker therapy is associated with a significant reduction in lead-related complication rate compared to conventional...

Back to Top