SU‐FF‐T‐384: Reliable Radiation Dosimetry for Acquiring Beam Data for a 6 MV Linac Based Stereotactic Radiosurgery

View through CrossRef
Purpose: To evaluate the reliability of the dosimetry systems available at our institution in the measurement of beam data for 6 MV linac based stereotactic radiosurgery. Method and Materials: The measurements of total scatter factor (St), tissue maximum ratio (TMR) were made by using X‐Omat V films, IC03, IC10, and a PTW Markus chambers. Only the films, IC03 and IC10 were employed in off axis ratio (OAR) measurements. Eight collimators with 10 to 50 mm diameters were involved in all measurements. Results: The TMR values measured by IC10 and Markus were agreeable within 2% for the collimators of 20 to 50 mm. The TMR values determined by all detectors for the collimators smaller than 20 mm may not be accurate enough for clinical use. The St values determined by all detectors with field sizes equal to or greater than 30 mm agreed within 2%. Markus and IC10 showed very closed values of St within 0.2%. For all collimators, the values of IC03 and film were about 1% less than the ones of Markus, and IC10. With the collimators of less than 25 mm, film presented the highest St values but Markus gave the highest values for the larger collimators. Film showed higher values of off axis ratios inside the beam area than IC10 and IC03 for all collimators. Comparisons of St Conclusions: From our study, it is concluded that the TMR values for 10 mm collimator should be measured by IC03 but the for larger collimators, IC10 is preferred. Among our detectors, film is the best one for the measurements of OAR for all collimators and St for the two small collimators (10 to 20 mm), with the larger collimators, Markus chamber should be used.
Title: SU‐FF‐T‐384: Reliable Radiation Dosimetry for Acquiring Beam Data for a 6 MV Linac Based Stereotactic Radiosurgery
Description:
Purpose: To evaluate the reliability of the dosimetry systems available at our institution in the measurement of beam data for 6 MV linac based stereotactic radiosurgery.
Method and Materials: The measurements of total scatter factor (St), tissue maximum ratio (TMR) were made by using X‐Omat V films, IC03, IC10, and a PTW Markus chambers.
Only the films, IC03 and IC10 were employed in off axis ratio (OAR) measurements.
Eight collimators with 10 to 50 mm diameters were involved in all measurements.
Results: The TMR values measured by IC10 and Markus were agreeable within 2% for the collimators of 20 to 50 mm.
The TMR values determined by all detectors for the collimators smaller than 20 mm may not be accurate enough for clinical use.
The St values determined by all detectors with field sizes equal to or greater than 30 mm agreed within 2%.
Markus and IC10 showed very closed values of St within 0.
2%.
For all collimators, the values of IC03 and film were about 1% less than the ones of Markus, and IC10.
With the collimators of less than 25 mm, film presented the highest St values but Markus gave the highest values for the larger collimators.
Film showed higher values of off axis ratios inside the beam area than IC10 and IC03 for all collimators.
Comparisons of St Conclusions: From our study, it is concluded that the TMR values for 10 mm collimator should be measured by IC03 but the for larger collimators, IC10 is preferred.
Among our detectors, film is the best one for the measurements of OAR for all collimators and St for the two small collimators (10 to 20 mm), with the larger collimators, Markus chamber should be used.

Related Results

SU‐C‐BRA‐03: Investigation of the Performance of a Simulated In‐Line 6 MV Linac in Longitudinal Magnetic Fields
SU‐C‐BRA‐03: Investigation of the Performance of a Simulated In‐Line 6 MV Linac in Longitudinal Magnetic Fields
Purpose: To achieve real‐time image guided radiotherapy, a linac‐MR system is designed with the linac located on the symmetry axis of the MRI. Thus, an investigation was performed ...
The Clinical Outcome of Hypofractionated Stereotactic Radiotherapy With CyberKnife Robotic Radiosurgery for Perioptic Pituitary Adenoma
The Clinical Outcome of Hypofractionated Stereotactic Radiotherapy With CyberKnife Robotic Radiosurgery for Perioptic Pituitary Adenoma
Stereotactic radiation technique including single fraction radiosurgery and conventional fractionated stereotactic radiotherapy is widely reported as an effective treatment of pitu...
Effect of longitudinal magnetic fields on a simulated in‐line 6 MV linac
Effect of longitudinal magnetic fields on a simulated in‐line 6 MV linac
Purpose:Linac‐magnetic resonance (MR) systems have been proposed in order to achieve real‐time image guided radiotherapy. The design of a new linac‐MR system with the in‐line 6 MV ...
Analysis of radiotherapy technology infrastructure and human resources in Vietnam
Analysis of radiotherapy technology infrastructure and human resources in Vietnam
In this study, the authors synthesise and analyse the re-sults of the 2019-2020 statistical survey on infrastructure and human resources of radiotherapy centers in Viet-nam, thereb...
Novalis Shaped Beam Radiosurgery of arteriovenous malformations
Novalis Shaped Beam Radiosurgery of arteriovenous malformations
Object. The authors studied outcomes and complications in patients who harbored arteriovenous malformations (AVMs) and underwent stereotactic radiosurgery involving the Novalis sha...
Novalis Shaped Beam Radiosurgery of arteriovenous malformations
Novalis Shaped Beam Radiosurgery of arteriovenous malformations
Object. The authors studied outcomes and complications in patients who harbored arteriovenous malformations (AVMs) and underwent stereotactic radiosurgery involving the Novalis sha...
P27.32.B V-REX RANDOMIZED TRIAL
P27.32.B V-REX RANDOMIZED TRIAL
Abstract IMPORTANCE Current guidelines for treating small- to medium-sized vestibular schwannoma recommend either upfront radios...

Back to Top