Evaluation of Dry-Gas Meters in Wet-Gas Conditions: Turbine and Venturi Meters

View through CrossRef
Abstract The accurate and reliable measurement of gas flowrate in wet gas conditions continues to be important to the Oil and Gas Industry. The ability to measure wet gas flows is particularly crucial in small, marginal developments that would otherwise be uneconomic to exploit due to the requirement for expensive separation equipment. This paper presents the results of two independent studies conducted on the new NEL high pressure wet gas test facility that uses nitrogen and a kerosene substitute (Exxsol D80) as test fluids to simulate a natural gas/ condensate system. The first study involved the the testing in wet gas of a 6- inch turbine meter in liquid loadings of up to 2% by mass at a pressure of 60 barg and pipe Reynolds numbers from 1 to 9 million. The maximum shift in the turbine meter factor found due to the presence of the kerosene was -0.75% at a Reynolds number of 2.7 million. Mechanisms that could cause the observed shifts are provided. These results presented here differ from published data taken for a similar test arrangement. Possible explanations for the disagreement are given. The second study was performed on a 6-inch (0.55 diameter ratio) Venturi meter manufactured to the ISO 5167 standard. Liquid contents up to 5% by volume, gas velocities from 6-15 m/s and line pressures of 20, 40 and 60 barg were used in the test programme. The calculated overreadings in gas flowrate are consistent with existing data. Introduction The metering of multiphase flows in the field is becoming more common due to requirements for the reduction of costs through removal of expensive separation equipment and the improvement of well management via sufficiently accurate and reliable real-time data. Wet gas flow measurement (as a subset of multiphase flow) is receiving particular attention by the industry due to limitations of existing multiphase flow measurement devices in the required high GVF range. The continued study of the response of current metering technologies using modern experimental test facilities that simulate field conditions is vital to the development of reliable techniques that can be used for determining gas flowrate in high GVF systems. Just such a facility has been available to the Oil and Gas Industry at the National Engineering Laboratory (NEL) since the summer of 1999. The results of two separate wet gas studies using this facility are reported in this paper. Typical examples of a turbine meter and Venturi meter have been exposed to high pressure wet gas flows and the responses obtained compared with their normal dry gas behaviour. The aims of each test programme were slightly different due to the nature of each meter type and their likely applications. For the turbine meter installation in a wet gas line is not advisable due to the likely damage that the meter would sustain. However, there are occasions when liquid can enter a dry gas metering run and therefore it is desirable to know the effect that a small quantity of liquid may have on the calibrated meter factor.
Title: Evaluation of Dry-Gas Meters in Wet-Gas Conditions: Turbine and Venturi Meters
Description:
Abstract The accurate and reliable measurement of gas flowrate in wet gas conditions continues to be important to the Oil and Gas Industry.
The ability to measure wet gas flows is particularly crucial in small, marginal developments that would otherwise be uneconomic to exploit due to the requirement for expensive separation equipment.
This paper presents the results of two independent studies conducted on the new NEL high pressure wet gas test facility that uses nitrogen and a kerosene substitute (Exxsol D80) as test fluids to simulate a natural gas/ condensate system.
The first study involved the the testing in wet gas of a 6- inch turbine meter in liquid loadings of up to 2% by mass at a pressure of 60 barg and pipe Reynolds numbers from 1 to 9 million.
The maximum shift in the turbine meter factor found due to the presence of the kerosene was -0.
75% at a Reynolds number of 2.
7 million.
Mechanisms that could cause the observed shifts are provided.
These results presented here differ from published data taken for a similar test arrangement.
Possible explanations for the disagreement are given.
The second study was performed on a 6-inch (0.
55 diameter ratio) Venturi meter manufactured to the ISO 5167 standard.
Liquid contents up to 5% by volume, gas velocities from 6-15 m/s and line pressures of 20, 40 and 60 barg were used in the test programme.
The calculated overreadings in gas flowrate are consistent with existing data.
Introduction The metering of multiphase flows in the field is becoming more common due to requirements for the reduction of costs through removal of expensive separation equipment and the improvement of well management via sufficiently accurate and reliable real-time data.
Wet gas flow measurement (as a subset of multiphase flow) is receiving particular attention by the industry due to limitations of existing multiphase flow measurement devices in the required high GVF range.
The continued study of the response of current metering technologies using modern experimental test facilities that simulate field conditions is vital to the development of reliable techniques that can be used for determining gas flowrate in high GVF systems.
Just such a facility has been available to the Oil and Gas Industry at the National Engineering Laboratory (NEL) since the summer of 1999.
The results of two separate wet gas studies using this facility are reported in this paper.
Typical examples of a turbine meter and Venturi meter have been exposed to high pressure wet gas flows and the responses obtained compared with their normal dry gas behaviour.
The aims of each test programme were slightly different due to the nature of each meter type and their likely applications.
For the turbine meter installation in a wet gas line is not advisable due to the likely damage that the meter would sustain.
However, there are occasions when liquid can enter a dry gas metering run and therefore it is desirable to know the effect that a small quantity of liquid may have on the calibrated meter factor.

Related Results

A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
Abstract The main causes of gas turbine performance degradation in natural gas combined cycle power plants are corrosion, fouling, and high turbine inlet temperature...
Complejidad y contradicción en Le Corbusier
Complejidad y contradicción en Le Corbusier
Resumen: En 1966 Robert Venturi publica Complexity and Contradiction in Architecture. Este libro representa uno de los alegatos más severos contra las limitaciones de la arquitectu...
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
This paper presents an experimental study of the impact of individual high-pressure turbine purge flows on the main flow in a downstream turbine center frame duct. Measurements wer...
RANCANG BANGUN VENTURI SCRUBBER TERHADAP PENURUNAN EMISI JELAGA
RANCANG BANGUN VENTURI SCRUBBER TERHADAP PENURUNAN EMISI JELAGA
The industrial world and vehicles that currently exist make the pollution level increase. Often we see thick smoke rising out of the factory chimney, the thick smoke is a waste of ...
Venturi Wet Gas Flow Modeling Based on Homogeneous and Separated Flow Theory
Venturi Wet Gas Flow Modeling Based on Homogeneous and Separated Flow Theory
Wet gas metering is becoming increasingly important to petroleum and chemical engineering. The Venturi meter is a favored device for the metering of the unprocessed wet natural gas...
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Gas turbine technology trends to be maturing now, but the problem of which not being able to reverse directly remains resolve. In the field of marine, most ships reverse by adjusta...
Large-Scale Application of Wet-Gas Metering at the Oman Upstream LNG Project
Large-Scale Application of Wet-Gas Metering at the Oman Upstream LNG Project
Abstract This paper describes the application of wet gas flow measurement to over 35 wells in the Oman Upstream LNG project. This multiphase metering process uses pe...
PENGARUH AIR FUEL RATIO (AFR) TERHADAP EFISIENSI TURBIN GAS
PENGARUH AIR FUEL RATIO (AFR) TERHADAP EFISIENSI TURBIN GAS
Gas turbine efficiency is an indicator to determine the performance of a generator. The greater the efficiency value of the gas turbine in a generator, the better the performance o...

Back to Top