Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PENGARUH AIR FUEL RATIO (AFR) TERHADAP EFISIENSI TURBIN GAS

View through CrossRef
Gas turbine efficiency is an indicator to determine the performance of a generator. The greater the efficiency value of the gas turbine in a generator, the better the performance of the generator. One of the things that affect the value of the efficiency of a gas turbine is the air fuel ratio. Air Fuel Ratio (AFR) is the ratio of the amount of air and fuel in the combustion process in units of mass or volume. Air fuel ratio is a factor that affects the perfection of the combustion process in the combustion chamber. In the graphic image it can be seen that the lowest AFR values are on July 3 and 4 2022, when the gas turbine produces a loading of 20900 kW and 20100 kW with an AFR value of 39.76 unitless each. Whereas the highest AFR value is on June 28 2022 when the gas turbine produces a loading of 20780 kW with an AFR value of 40.68 unitless. The highest gas turbine efficiency value is on June 30, 2022, at a loading of 20,650 kW with a gas turbine efficiency of 83.3%. The lowest efficiency value is on July 2, 2022, at a load of 20,800 kW with a gas turbine efficiency of 81.05%. From the results of existing data processing and graphs, it can be seen that the value of the air fuel ratio and the efficiency of the gas turbine are inversely proportional, which means that when the value of the air fuel ratio decreases, the value of the efficiency of the gas turbine tends to increase. However, there are some deviations when the value of the air fuel ratio decreases, the efficiency of the gas turbine also decreases. Therefore it can be concluded that the value of the air fuel ratio affects the value of the efficiency of the gas turbine, however, the value of the air fuel ratio is not the only factor that affects the value of the efficiency of the gas turbine.
Title: PENGARUH AIR FUEL RATIO (AFR) TERHADAP EFISIENSI TURBIN GAS
Description:
Gas turbine efficiency is an indicator to determine the performance of a generator.
The greater the efficiency value of the gas turbine in a generator, the better the performance of the generator.
One of the things that affect the value of the efficiency of a gas turbine is the air fuel ratio.
Air Fuel Ratio (AFR) is the ratio of the amount of air and fuel in the combustion process in units of mass or volume.
Air fuel ratio is a factor that affects the perfection of the combustion process in the combustion chamber.
In the graphic image it can be seen that the lowest AFR values are on July 3 and 4 2022, when the gas turbine produces a loading of 20900 kW and 20100 kW with an AFR value of 39.
76 unitless each.
Whereas the highest AFR value is on June 28 2022 when the gas turbine produces a loading of 20780 kW with an AFR value of 40.
68 unitless.
The highest gas turbine efficiency value is on June 30, 2022, at a loading of 20,650 kW with a gas turbine efficiency of 83.
3%.
The lowest efficiency value is on July 2, 2022, at a load of 20,800 kW with a gas turbine efficiency of 81.
05%.
From the results of existing data processing and graphs, it can be seen that the value of the air fuel ratio and the efficiency of the gas turbine are inversely proportional, which means that when the value of the air fuel ratio decreases, the value of the efficiency of the gas turbine tends to increase.
However, there are some deviations when the value of the air fuel ratio decreases, the efficiency of the gas turbine also decreases.
Therefore it can be concluded that the value of the air fuel ratio affects the value of the efficiency of the gas turbine, however, the value of the air fuel ratio is not the only factor that affects the value of the efficiency of the gas turbine.

Related Results

PENGUJIAN TURBIN ANGIN DARRIEUS DI PANTAI MATEMATIK DELI SERDANG DENGAN VARIASI JUMLAH BLADE
PENGUJIAN TURBIN ANGIN DARRIEUS DI PANTAI MATEMATIK DELI SERDANG DENGAN VARIASI JUMLAH BLADE
Salah satu faktor yang mempengaruhi efisiensi energi yang dibangkitkan adalah jumlah bilah angin. Penelitian ini dapat memberikan reverensi kepada masyarakat secara umum dan khusus...
Pembuatan Turbin Air Tipe Crossflow sebagai Penggerak Generator Fase-tunggal pada Pembangkit Listrik Tenaga Pikohidro
Pembuatan Turbin Air Tipe Crossflow sebagai Penggerak Generator Fase-tunggal pada Pembangkit Listrik Tenaga Pikohidro
Turbin air tipe crossflow merupakan jenis turbin yang dapat dioperasikan pada head rendah dengan debit air disesuaikan dengan aliran air dengan nilai efisiensi mekanis tinggi, sehi...
PENGARUH BUKAAN SUDU PENGARAH TERHADAP KERUGIAN HEAD DAN PERFORMANSI TURBIN FRANCIS VERTIKAL
PENGARUH BUKAAN SUDU PENGARAH TERHADAP KERUGIAN HEAD DAN PERFORMANSI TURBIN FRANCIS VERTIKAL
Pembangkit Listrik Tenaga Air masih menjadi tumpuan utama pembangkitan energi listrik di dunia khususnya Indonesia.Data pada tahun 2006 menunjukan bahwa hampir 20% kebutuhan listri...
Penentuan Dimensi Sudu Turbin dan Sudut Kemiringan Poros Turbin pada Turbin Ular Archimedes
Penentuan Dimensi Sudu Turbin dan Sudut Kemiringan Poros Turbin pada Turbin Ular Archimedes
Abstrak  Telah dilakukan penelitian penentuan dimensi sudu turbin dan sudut kemiringan poros turbin pada turbin ulir Archimedes.  Penelitian ini melakukan kajian pada beberapa para...
Pengaruh Deposisi dan Erosi Pada Sudu-Sudu Terhadap Kinerja Turbin PLT Panas Bumi Patuha
Pengaruh Deposisi dan Erosi Pada Sudu-Sudu Terhadap Kinerja Turbin PLT Panas Bumi Patuha
Turbin uap seringkali mengalami masalah deposisi dan erosi pada bagian sudu yang dapat menurunkan kinerja turbin uap. Oleh karena itu, diperlukan analisis deposisi dan erosi pada s...
EVALUASI KINERJA TURBIN GAS ABB GT 13-E1 DI PT INDONESIA POWER UBP PRIOK
EVALUASI KINERJA TURBIN GAS ABB GT 13-E1 DI PT INDONESIA POWER UBP PRIOK
Turbin Gas merupakan salah satu komponen terpenting dalam sistem PLTG dan PLTGU, maka dari itu tnrbin gas memerlukan perhatian lebih sehingga perlu dila...
Perancangan turbin uap untuk siklus gabungan
Perancangan turbin uap untuk siklus gabungan
Turbin gas beroperasi pada temperatur yang tinggi, sekitar 1100 — 1650”C. Temperatur gas-gas hasil pembakaran pada turbin gas biasanya masih cukup tinggi, sehingga masih mengandung...

Back to Top