A High-Voltage “Sen” Transformer: Configuration, Principles, and Applications

View through CrossRef
As is well known, the high installation and operational costs of the unified power flow controller (UPFC) restrict its widespread applications in power grid. An economical “Sen” transformer (ST) that is composed of a three-phase four-winding transformer and three sets of tap changers provides similar power flow control functionality as the UPFC. Unfortunately, the ST is not suitable for high-voltage systems because of its high-voltage insulation requirement on all secondary windings and tap changers. To overcome this problem, a high-voltage “Sen” transformer that consists of a three-phase two-winding transformer and two sets of tap changers is proposed in this paper. In high-voltage power system applications, the high-voltage “Sen” transformer (HVST) offers several advantages over the ST, such as fewer windings, fewer tap changers, bigger phase-shift range, and larger power flow control region. This paper focuses on the configuration, principles, and applications of the HVST. The contrastive simulation results in a two-area test system and an IEEE 39 bus system prove the validity and advantages of the proposed HVST. Moreover, a 10 kV HVST device and a corresponding experiment platform are developed to verify the feasibility and effectiveness of the HVST. The HVST can provide a flexible voltage and power flow control.
Title: A High-Voltage “Sen” Transformer: Configuration, Principles, and Applications
Description:
As is well known, the high installation and operational costs of the unified power flow controller (UPFC) restrict its widespread applications in power grid.
An economical “Sen” transformer (ST) that is composed of a three-phase four-winding transformer and three sets of tap changers provides similar power flow control functionality as the UPFC.
Unfortunately, the ST is not suitable for high-voltage systems because of its high-voltage insulation requirement on all secondary windings and tap changers.
To overcome this problem, a high-voltage “Sen” transformer that consists of a three-phase two-winding transformer and two sets of tap changers is proposed in this paper.
In high-voltage power system applications, the high-voltage “Sen” transformer (HVST) offers several advantages over the ST, such as fewer windings, fewer tap changers, bigger phase-shift range, and larger power flow control region.
This paper focuses on the configuration, principles, and applications of the HVST.
The contrastive simulation results in a two-area test system and an IEEE 39 bus system prove the validity and advantages of the proposed HVST.
Moreover, a 10 kV HVST device and a corresponding experiment platform are developed to verify the feasibility and effectiveness of the HVST.
The HVST can provide a flexible voltage and power flow control.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Analisis Penggunaan Transformator Sisipan Untuk Mengatasi Rugi Tegangan dan Pembebanan Lebih
Analisis Penggunaan Transformator Sisipan Untuk Mengatasi Rugi Tegangan dan Pembebanan Lebih
On the JD267 distribution transformer with a capacity of 100 kVA at the Kalibaru feeder on the PT PLN (Persero) ULP Genteng experienced  overloading at WBP (88.03%) and high voltag...
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
The system voltage may be negatively impacted by the transformer’s energisation which draws a large value of magnetising inrush current for a few seconds. During the transformer’s ...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...