Measurement and Comparison of Mechanical Properties of Nitinol Stents
View through CrossRef
The self expandable Nitinol stents or stentgrafts are typically used for miniinvasive treatment of stenosis and aneurysms in the cardiovascular system. The minimal traumatisation of the patient, shorter time of hospitalization are typical advantages of these methods. More than ten years of experience has yielded also important information about the performance of stents in interaction with biological system and the possible problems related with it. The leakage or the shift of stent are some typical disadvantages, that can be related among other in the construction of the stent. The problem is that the mechanical properties, dimensions and the dynamical properties of the stent do not exactly correspond to the properties of the vessel or generally of tissue where this stent is introduced. The measurement, the description and the comparison of the relations between the mechanical properties of stents and tissues can be one of the possible ways to minimize these disadvantages. The developed original computer controlled measuring system allows the measurement of mechanical properties of stents, the measurement of strain-stress curves or simulation of interaction of the stent and vessel for exactly defined hemodynamic conditions. We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in geometry (radius and length), in the type of construction (number of branches and rising of winding) and in the diameter of used wire. The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences the rigidity and the level of compressibility of the stent as well. A compromise must be found between the required rigidity of the stent and the minimal size of the delivery system. The exact description of the relation between the mechanical properties and geometry and construction of the stents enables to design the stent to fit the patient and it is expected that this access improves the efficiency of treatment. The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.
Title: Measurement and Comparison of Mechanical Properties of Nitinol Stents
Description:
The self expandable Nitinol stents or stentgrafts are typically used for miniinvasive treatment of stenosis and aneurysms in the cardiovascular system.
The minimal traumatisation of the patient, shorter time of hospitalization are typical advantages of these methods.
More than ten years of experience has yielded also important information about the performance of stents in interaction with biological system and the possible problems related with it.
The leakage or the shift of stent are some typical disadvantages, that can be related among other in the construction of the stent.
The problem is that the mechanical properties, dimensions and the dynamical properties of the stent do not exactly correspond to the properties of the vessel or generally of tissue where this stent is introduced.
The measurement, the description and the comparison of the relations between the mechanical properties of stents and tissues can be one of the possible ways to minimize these disadvantages.
The developed original computer controlled measuring system allows the measurement of mechanical properties of stents, the measurement of strain-stress curves or simulation of interaction of the stent and vessel for exactly defined hemodynamic conditions.
We measured and compared the mechanical parameters of different selfexpandable Nitinol stents, which differed in geometry (radius and length), in the type of construction (number of branches and rising of winding) and in the diameter of used wire.
The results of measurements confirmed the theoretical assumptions that just the diameter of the Nitinol wire significantly influences the rigidity and the level of compressibility of the stent as well.
A compromise must be found between the required rigidity of the stent and the minimal size of the delivery system.
The exact description of the relation between the mechanical properties and geometry and construction of the stents enables to design the stent to fit the patient and it is expected that this access improves the efficiency of treatment.
The results of measurement are also necessary for the design and identification of the parameters of the models of the stents.
Related Results
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Objective
In prior research, we employed artificial intelligence (AI) to distinguish different anatomical positions in the airway under bronchoscopy. We aimed to levera...
P75 CRITICAL APPRAISAL OF THE IMPACT OF OESOPHAGEAL STENTS IN THE MANAGEMENT OF OESOPHAGEAL ANASTOMOTIC LEAKS AND BENIGN OESOPHAGEAL PERFORATIONS: AN UPDATED SYSTEMATIC REVIEW
P75 CRITICAL APPRAISAL OF THE IMPACT OF OESOPHAGEAL STENTS IN THE MANAGEMENT OF OESOPHAGEAL ANASTOMOTIC LEAKS AND BENIGN OESOPHAGEAL PERFORATIONS: AN UPDATED SYSTEMATIC REVIEW
Abstract
Aims
This updated systematic review aimed to assess the safety and effectiveness of oesophageal stents in these two sce...
Features of the Structural Design of Welded Joints of Superelastic Nitinol Wires
Features of the Structural Design of Welded Joints of Superelastic Nitinol Wires
The object of the study is a permanent joint of thin wires made of nitinol alloy. The problem of ensuring the formation of a joint of wires made of nitinol alloy was solved based o...
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Abstract
Background: To investigate the clinicopathological and etiological characteristics for urinary tract infections in cervical cancer radical surgery with indwelling ...
Determination of the structural features of joint material of the nitinol wires made by laser welding
Determination of the structural features of joint material of the nitinol wires made by laser welding
The object of the study is the welded joint of thin wires made of nitinol alloy. The problem of ensuring the formation of a joint of wires with a diameter of 0.8 mm made of nitinol...
e0506 Application of overlapped sirolimus-eluting stents in treatment of long coronary arteries lesion
e0506 Application of overlapped sirolimus-eluting stents in treatment of long coronary arteries lesion
Objective
To evaluate the clinical efficacy of overlapped Excel and Cypher stents in treatment for long coronary arteries lesion.
...
Impact of drug eluting stents on the progression of coronary artery atherosclerotic plaque
Impact of drug eluting stents on the progression of coronary artery atherosclerotic plaque
Objective
The objective of this study was to evaluate whether the drug eluting stents can affect the progression of coronary artery atherosclerotic plaque.
...
Initial experience with the disarticulated (one‐half) palmaz‐schatz stent: A technical report
Initial experience with the disarticulated (one‐half) palmaz‐schatz stent: A technical report
AbstractWe developed an alternative method to stent suitable lesions located in anatomical settings considered to be too complex for regular Palmaz‐Schatz stent placement. This met...