Modulated Degradation of Polylactic Acid Electrospun Coating on WE43 Stents
View through CrossRef
Magnesium-based coronary stents have gained significant interest due to their excellent biocompatibility, biodegradability, and mechanical properties. However, a key limitation of magnesium in biomedical applications is its low corrosion resistance, which compromises its structural integrity and mechanical strength over time. Polymeric coatings can overcome this challenge, enhancing magnesium-based implants’ corrosion resistance and overall performance. This study applied a polylactic acid (PLA) nanofiber coating to WE43 magnesium (Mg) stents via electrospinning to reduce their corrosion rate. Both uncoated and coated stents underwent in vitro immersion tests in Hank’s solution for 1, 3, 7, and 14 days. The effectiveness of the PLA coating was evaluated through morphological analysis, chemical composition assessment, corrosion behavior (weight change), magnesium ion release, and in vitro biocompatibility. The corrosion observed in the uncoated WE43 stents indicates that protective coatings are necessary to regulate degradation rates over extended implantation periods. The results demonstrated that coated stents exhibited improved performance, maintaining the integrity of the PLA coating for up to 14 days. The coated stents demonstrated reduced surface damage and lower weight loss resulting from lower magnesium release. In our study, the coated stents demonstrated a reduced corrosion rate (0.216 ± 0.013 mm/year) compared with the uncoated stents (0.312 ± 0.010 mm/year), both after 14 days. Additionally, in vitro biocompatibility results confirmed the non-toxic nature of PLA-coated stents, which enhances cellular proliferation and contributes to a more favorable environment for vascular healing. These findings suggest that PLA coatings can effectively prolong the functional durability of WE43 Mg stents, offering a promising solution for enhancing the performance of biodegradable stents in cardiovascular applications.
Title: Modulated Degradation of Polylactic Acid Electrospun Coating on WE43 Stents
Description:
Magnesium-based coronary stents have gained significant interest due to their excellent biocompatibility, biodegradability, and mechanical properties.
However, a key limitation of magnesium in biomedical applications is its low corrosion resistance, which compromises its structural integrity and mechanical strength over time.
Polymeric coatings can overcome this challenge, enhancing magnesium-based implants’ corrosion resistance and overall performance.
This study applied a polylactic acid (PLA) nanofiber coating to WE43 magnesium (Mg) stents via electrospinning to reduce their corrosion rate.
Both uncoated and coated stents underwent in vitro immersion tests in Hank’s solution for 1, 3, 7, and 14 days.
The effectiveness of the PLA coating was evaluated through morphological analysis, chemical composition assessment, corrosion behavior (weight change), magnesium ion release, and in vitro biocompatibility.
The corrosion observed in the uncoated WE43 stents indicates that protective coatings are necessary to regulate degradation rates over extended implantation periods.
The results demonstrated that coated stents exhibited improved performance, maintaining the integrity of the PLA coating for up to 14 days.
The coated stents demonstrated reduced surface damage and lower weight loss resulting from lower magnesium release.
In our study, the coated stents demonstrated a reduced corrosion rate (0.
216 ± 0.
013 mm/year) compared with the uncoated stents (0.
312 ± 0.
010 mm/year), both after 14 days.
Additionally, in vitro biocompatibility results confirmed the non-toxic nature of PLA-coated stents, which enhances cellular proliferation and contributes to a more favorable environment for vascular healing.
These findings suggest that PLA coatings can effectively prolong the functional durability of WE43 Mg stents, offering a promising solution for enhancing the performance of biodegradable stents in cardiovascular applications.
Related Results
Coating Processes of Pharmaceutical Applicability: A Glimpse
Coating Processes of Pharmaceutical Applicability: A Glimpse
Presentation of manuscript is aiming to furnish glimpse on coating processes. Coating is process of snugly covering substrate surface with coating materials (CoM). In due course co...
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Objective
In prior research, we employed artificial intelligence (AI) to distinguish different anatomical positions in the airway under bronchoscopy. We aimed to levera...
The Microstructure of WE43 MMC Reinforced with SiC Particles
The Microstructure of WE43 MMC Reinforced with SiC Particles
It is well known that the properties of a metal matrix composites depend upon the properties of the reinforcement phase, of the matrix and of the interface. A strong interface bond...
Influence of Manufacturing Parameters on the Properties of 3D Printed Polylactic Acid Carbon Fiber Components
Influence of Manufacturing Parameters on the Properties of 3D Printed Polylactic Acid Carbon Fiber Components
This study investigates the impact of printing parameters on fused filament fabrication parts using Polylactic acid and polylactic acid carbon fibre filament. It aims to determine ...
SUSTAINABLE ANTIBACTERIAL NANOFIBRES: ELECTROSPUN CELLULOSE ACETATE FROM OIL PALM WASTE REINFORCED WITH SILVER NANOPARTICLES
SUSTAINABLE ANTIBACTERIAL NANOFIBRES: ELECTROSPUN CELLULOSE ACETATE FROM OIL PALM WASTE REINFORCED WITH SILVER NANOPARTICLES
A study on the isolation and characterization of electrospun cellulose acetate nanofibres derived from oil palm empty fruit bunches and their antibacterial properties with silver n...
P75 CRITICAL APPRAISAL OF THE IMPACT OF OESOPHAGEAL STENTS IN THE MANAGEMENT OF OESOPHAGEAL ANASTOMOTIC LEAKS AND BENIGN OESOPHAGEAL PERFORATIONS: AN UPDATED SYSTEMATIC REVIEW
P75 CRITICAL APPRAISAL OF THE IMPACT OF OESOPHAGEAL STENTS IN THE MANAGEMENT OF OESOPHAGEAL ANASTOMOTIC LEAKS AND BENIGN OESOPHAGEAL PERFORATIONS: AN UPDATED SYSTEMATIC REVIEW
Abstract
Aims
This updated systematic review aimed to assess the safety and effectiveness of oesophageal stents in these two sce...
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Abstract
Background: To investigate the clinicopathological and etiological characteristics for urinary tract infections in cervical cancer radical surgery with indwelling ...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...