Javascript must be enabled to continue!
Right Ventricular Dysfunction in Patients With Severe Aortic Stenosis Before and After Transcatheter Aortic Valve Implantation
View through CrossRef
ABSTRACT
Purpose
Right ventricular dysfunction (RVD) is a prognostic factor in patients with severe aortic stenosis (AS). Some patients have prolonged RVD after transcatheter aortic valve implantation (TAVI). We aimed to identify the prevalence of RVD before and after TAVI and factors associated with preexisting and prolonged RVD in patients with severe AS.
Methods
This retrospective single‐center study included 198 patients with severe AS (86.0 ± 4.8 years; 72.7% female). RVD was defined as two of the three parameters being worse than the reference value: fractional area change, right ventricular free wall strain, and tricuspid annular plane systolic excursion.
Results
Sixty‐eight patients (34.3%) were diagnosed with preexisting RVD. Factors associated with preexisting RVD were left ventricular (LV) ejection fraction, LV stroke volume index, and ratio of early diastolic velocity to early diastolic annular velocity (E/e′) on the septal side in a multivariable analysis combining baseline clinical and echocardiographic parameters (all
p
< 0.05). One year after TAVI, 16 of 47 patients (34.0%) were classified as having prolonged RVD. Patients with prolonged RVD had lower LV stroke volume index, greater relative wall thickness, and lower aortic valve mean pressure gradient before TAVI than patients without prolonged RVD (all
p
< 0.05).
Conclusion
RVD in patients with severe AS is associated with lower LV ejection fraction, lower LV stroke volume index, and higher septal E/e′ at baseline. Smaller LV stroke volume, lower aortic valve mean pressure gradient, and greater relative wall thickness might be predictors of prolonged RVD 1 year after TAVI.
Title: Right Ventricular Dysfunction in Patients With Severe Aortic Stenosis Before and After Transcatheter Aortic Valve Implantation
Description:
ABSTRACT
Purpose
Right ventricular dysfunction (RVD) is a prognostic factor in patients with severe aortic stenosis (AS).
Some patients have prolonged RVD after transcatheter aortic valve implantation (TAVI).
We aimed to identify the prevalence of RVD before and after TAVI and factors associated with preexisting and prolonged RVD in patients with severe AS.
Methods
This retrospective single‐center study included 198 patients with severe AS (86.
0 ± 4.
8 years; 72.
7% female).
RVD was defined as two of the three parameters being worse than the reference value: fractional area change, right ventricular free wall strain, and tricuspid annular plane systolic excursion.
Results
Sixty‐eight patients (34.
3%) were diagnosed with preexisting RVD.
Factors associated with preexisting RVD were left ventricular (LV) ejection fraction, LV stroke volume index, and ratio of early diastolic velocity to early diastolic annular velocity (E/e′) on the septal side in a multivariable analysis combining baseline clinical and echocardiographic parameters (all
p
< 0.
05).
One year after TAVI, 16 of 47 patients (34.
0%) were classified as having prolonged RVD.
Patients with prolonged RVD had lower LV stroke volume index, greater relative wall thickness, and lower aortic valve mean pressure gradient before TAVI than patients without prolonged RVD (all
p
< 0.
05).
Conclusion
RVD in patients with severe AS is associated with lower LV ejection fraction, lower LV stroke volume index, and higher septal E/e′ at baseline.
Smaller LV stroke volume, lower aortic valve mean pressure gradient, and greater relative wall thickness might be predictors of prolonged RVD 1 year after TAVI.
Related Results
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Background: Aortic regurgitation (AR), which has ill-defined predictors and an unknown long-term influence on outcomes, is a significant transcatheter aortic valve replacement (TAV...
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease be...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Abstract 13177: The Association Between Insufficient Valve Expansion and Aortic Valve Calcification for Transcatheter Valve Implantation With Self-Expandable Valve
Abstract 13177: The Association Between Insufficient Valve Expansion and Aortic Valve Calcification for Transcatheter Valve Implantation With Self-Expandable Valve
Background:
Transcatheter aortic valve implantation (TAVI) has emerged as the preferred treatment for severe aortic stenosis. Nevertheless, severe calcification remains...
P1718 Multi-modal imaging characterization of contained aortic subannular rupture after transcatheter aortic valve implantation
P1718 Multi-modal imaging characterization of contained aortic subannular rupture after transcatheter aortic valve implantation
Abstract
INTRODUCTION
Aortic annular rupture is a potentially catastrophic complication after transcatheter aortic valve implant...
Outcomes of complete mitral valve excision and replacement with tilting disc (TTK Chitra) valve for rheumatic mitral valve stenosis
Outcomes of complete mitral valve excision and replacement with tilting disc (TTK Chitra) valve for rheumatic mitral valve stenosis
Background:
Mitral valve (MV) disease is one of the earliest diseases of the heart, and rheumatic MV disease is one of the first discovered in the world dating back to ...
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Abstract
Introduction
Positron emission tomography-computed tomography (PET-CT) with 18F-sodium fluoride (18F-NaF) has been used...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...

