Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Long-term Evaluation of HPGe Calibration for Environmental Radioactivity Assessment Using IAEA-U and IAEA-Th Sources

View through CrossRef
The investigation of the dynamics between environmental radioactivity and its implications for human health stands as a fundamental pursuit in contemporary scientific research. Employing the Gamma Spectrometry technique, particularly utilizing High Purity Germanium (HPGe) detectors, emerges as a pivotal methodology to study environmental radioactivity with precision. The veracity and dependability of these analyses hinge upon the scrupulous and precise energy and efficiency calibration of the HPGe system. Within this framework,  we used calibrated IAEA-U and IAEA-Th sources, thereby not only ensuring measurement accuracy but also establishing a robust foundation for comprehensive evaluation of radioactivity levels. Our findings illuminate a comprehensive understanding of the energy and efficiency calibration of the HPGe detector, exemplified by linear relationships in the energy calibration curves for both IAEA-U and IAEA-Th sources, manifesting high correlation coefficients (R² > 0.99). Essential for translating count rates to activity, the efficiency calibration consistently yielded low errors, with the maximum observed efficiency error being less than 4% for both sources, significantly below the recommended by standard rules. This study affirms the reliability and stability of our calibration methods through repeatability assessments over four years. Looking forward, the calibrated HPGe systems are prepared to assume a central role in the spectral analysis of different Italian terrains. Application of these calibrated detectors to Italian soil aims to discern and quantify the presence of radionuclides, thereby contributing into the radioprotection of the region. This prospective dimension underscores the practical application and broader implications of our calibrated systems in addressing environmental and health-related concerns.
Title: Long-term Evaluation of HPGe Calibration for Environmental Radioactivity Assessment Using IAEA-U and IAEA-Th Sources
Description:
The investigation of the dynamics between environmental radioactivity and its implications for human health stands as a fundamental pursuit in contemporary scientific research.
Employing the Gamma Spectrometry technique, particularly utilizing High Purity Germanium (HPGe) detectors, emerges as a pivotal methodology to study environmental radioactivity with precision.
The veracity and dependability of these analyses hinge upon the scrupulous and precise energy and efficiency calibration of the HPGe system.
Within this framework,  we used calibrated IAEA-U and IAEA-Th sources, thereby not only ensuring measurement accuracy but also establishing a robust foundation for comprehensive evaluation of radioactivity levels.
Our findings illuminate a comprehensive understanding of the energy and efficiency calibration of the HPGe detector, exemplified by linear relationships in the energy calibration curves for both IAEA-U and IAEA-Th sources, manifesting high correlation coefficients (R² > 0.
99).
Essential for translating count rates to activity, the efficiency calibration consistently yielded low errors, with the maximum observed efficiency error being less than 4% for both sources, significantly below the recommended by standard rules.
This study affirms the reliability and stability of our calibration methods through repeatability assessments over four years.
Looking forward, the calibrated HPGe systems are prepared to assume a central role in the spectral analysis of different Italian terrains.
Application of these calibrated detectors to Italian soil aims to discern and quantify the presence of radionuclides, thereby contributing into the radioprotection of the region.
This prospective dimension underscores the practical application and broader implications of our calibrated systems in addressing environmental and health-related concerns.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
The IAEA’s Marine Radioactivity Information System MARIS: novel developments facilitating data sharing and scientific studies
The IAEA’s Marine Radioactivity Information System MARIS: novel developments facilitating data sharing and scientific studies
Levels of radionuclides in seawater, marine sediment and marine organisms can be influenced by a range of manmade inputs (e.g. nuclear accidents and authorised discharges from nucl...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Calibration HPGe detector using IAEA-U source for CBRNe
Calibration HPGe detector using IAEA-U source for CBRNe
AbstractDetecting and preventing the illicit movement of radioactive materials within a country is crucial, requiring the identification of radiologic anomalies against the normal ...

Back to Top