Javascript must be enabled to continue!
Low radiation dose calibration and theoretical model of an optical fiber dosimeter for the International Space Station
View through CrossRef
The optical-fiber-based dosimeter of the LUMINA project was deployed in August 2021 in the International Space Station in the framework of the Alpha mission. The sensing elements of the dosimeter are P-doped optical fibers, which were proven to be excellent candidates for dosimetry applications. The twofold objective of this paper is to provide a theoretical model for the radiation response of the dosimeter and to report on the experimental work carried out at CERN for the qualification and calibration of the engineering model of the LUMINA dosimeter. Combining the theoretical response and experimental data, the calibration curve of the flight model is obtained. Finally, this study broadens the investigation of the room temperature radiation response of P-doped optical fibers in a range of dose rates 104 times lower than previously reported, from 21µGy(SiO2)/h to 145mGy(SiO2)/h.
Title: Low radiation dose calibration and theoretical model of an optical fiber dosimeter for the International Space Station
Description:
The optical-fiber-based dosimeter of the LUMINA project was deployed in August 2021 in the International Space Station in the framework of the Alpha mission.
The sensing elements of the dosimeter are P-doped optical fibers, which were proven to be excellent candidates for dosimetry applications.
The twofold objective of this paper is to provide a theoretical model for the radiation response of the dosimeter and to report on the experimental work carried out at CERN for the qualification and calibration of the engineering model of the LUMINA dosimeter.
Combining the theoretical response and experimental data, the calibration curve of the flight model is obtained.
Finally, this study broadens the investigation of the room temperature radiation response of P-doped optical fibers in a range of dose rates 104 times lower than previously reported, from 21µGy(SiO2)/h to 145mGy(SiO2)/h.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Alanine dosimeters are generally used in high-dose dosimetry, while accurate and precise dose delivery verification procedures are important in stereotactic radiosurgery (SRS). Hen...
Effect of FBG Fiber Dosimeter Division in Sensing Capability for Low Radiation Doses
Effect of FBG Fiber Dosimeter Division in Sensing Capability for Low Radiation Doses
ر
A fiber Bragg grating (FBG) as a dosimeter is developed in this simulation study (based on Optisystem 21 software) by dividing its region into five individual regions. The divis...
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
A computed tomography dose index can be used to quantify the radiation dose received during a CT scan and it is an indicator of the radiation dose to the polymetaylenmetaAcrylate (...
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Background: Alanine dosimeters are generally used in high-dose industrial applications (kGy). Later, research into employing alanine as a dosimeter in radiotherapy (1-20 Gy) has in...
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
AbstractPurposeRadiochromic films are versatile 2D dosimeters with high‐resolution and near tissue equivalence. To assure high precision and accuracy, a time‐consuming calibration ...
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Cathlab radiation workers, when performing interventional procedures, are at high risk of the effects of radiation exposure. The risk of radiation exposure is deterministic and sto...
Improved Dosimetry in Radiotherapy with Gold-Coated Fiber Optics
Improved Dosimetry in Radiotherapy with Gold-Coated Fiber Optics
Abstract
Background: Patients receiving radiotherapy, a clinical treatment process in which radiation is used for the treatment of various types of cancer, utilize a varie...

