Effect of pupil dilation on IOLMaster® measurements in Pakistani Eyes

View through CrossRef
Objective: To analyse the effect of pupil dilation on intraocular lens instrument IOLMaster 500 biometric measurements, and to determine the effect of these measurements on intraocular lens power calculations in Asian eyes. Methods: The prospective study was conducted at the Aga Khan University Hospital, Karachi, between January and April 2017, and comprised all patients scheduled for cataract surgery who underwent scanning with IOLMaster 500. For each patient, pre-dilation and post-dilation measurements were taken. The intraocular lens power was determined through Sanders/Retzlaff/Kraff Theoretical, Holladay, and Hoffer Q formulae. Data was analysed using SPSS 24. Results: There were 276 eyes of 138 participants who had a mean age of 59.7±11.1 years. Anterior chamber depth changed significantly with pupil dilation (p=0.001). No significant changes were observed in the axial length (p=0.410), keratometry measurements (p=0.931), and intraocular lens power calculations (p>0.05). Conclusions: The change in anterior chamber depth, though significant, was perhaps clinically non-significant. intraocular lens power did not exhibit any significant differences post-mydriasis. Key Words: Mydriasis, Lenses, Intraocular, Lens, Implantation, Phakic intraocular lenses, Biometry.
Title: Effect of pupil dilation on IOLMaster® measurements in Pakistani Eyes
Description:
Objective: To analyse the effect of pupil dilation on intraocular lens instrument IOLMaster 500 biometric measurements, and to determine the effect of these measurements on intraocular lens power calculations in Asian eyes.
Methods: The prospective study was conducted at the Aga Khan University Hospital, Karachi, between January and April 2017, and comprised all patients scheduled for cataract surgery who underwent scanning with IOLMaster 500.
For each patient, pre-dilation and post-dilation measurements were taken.
The intraocular lens power was determined through Sanders/Retzlaff/Kraff Theoretical, Holladay, and Hoffer Q formulae.
Data was analysed using SPSS 24.
Results: There were 276 eyes of 138 participants who had a mean age of 59.
7±11.
1 years.
Anterior chamber depth changed significantly with pupil dilation (p=0.
001).
No significant changes were observed in the axial length (p=0.
410), keratometry measurements (p=0.
931), and intraocular lens power calculations (p>0.
05).
Conclusions: The change in anterior chamber depth, though significant, was perhaps clinically non-significant.
intraocular lens power did not exhibit any significant differences post-mydriasis.
Key Words: Mydriasis, Lenses, Intraocular, Lens, Implantation, Phakic intraocular lenses, Biometry.

Related Results

Comparison of four formulas for the intraocular lens power prediction
Comparison of four formulas for the intraocular lens power prediction
Abstract Purpose To assess the accuracy of four formulas for intraocular lens (IOL) power prediction in cataractous eyes. METHODS In this prospective study, 51 eyes of 3...
Examining pupil characteristics and relative afferent pupil defect prevalence in Syrian patients
Examining pupil characteristics and relative afferent pupil defect prevalence in Syrian patients
Purpose: This study aims to explore pupil characteristics in a cohort of Syrian patients across different age groups and under varying luminance conditions, both pre- a...
Sympathetic Nervous System Does Not Mediate Reflex Pupillary Dilation during Desflurane Anesthesia
Sympathetic Nervous System Does Not Mediate Reflex Pupillary Dilation during Desflurane Anesthesia
Background Pupil size is determined by an interaction between the sympathetic and parasympathetic divisions of the autonomic nervous system. Noxious stimulation dilates...
Pupil diameter tracked during motor adaptation in humans
Pupil diameter tracked during motor adaptation in humans
Abstract Pupil diameter, under constant illumination, is known to reflect individuals’ internal states, such as surprise about observation and environmental uncerta...
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Purpose: To compare toric IOL (Intra Ocular Lenses) suggestions for power, toric, and IOL alignment between the IOLMaster 700 and Pentacam AXL (Axial Length). Methods: This single-...
Assessment of pupillary light reflex using dynamic pupillometry in laser-treated eyes with retinal vein occlusion
Assessment of pupillary light reflex using dynamic pupillometry in laser-treated eyes with retinal vein occlusion
Purpose: This study aims to evaluate the pupillary light reflex measured with dynamic pupillometry in patients who underwent retinal laser photocoagulation due to unilateral retina...
A YOLO Detector Providing Fast and Accurate Pupil Center Estimation using Regions Surrounding a Pupil
A YOLO Detector Providing Fast and Accurate Pupil Center Estimation using Regions Surrounding a Pupil
Eye-tracking technology has many useful applications, including Virtual Reality (VR) devices, Augmented Reality (AR) devices, and assistive technology. The main objective of eye-tr...
Romatoid Artritli Hastalarda Statik ve Dinamik Pupillometri Parametrelerinin Değerlendirilmesi
Romatoid Artritli Hastalarda Statik ve Dinamik Pupillometri Parametrelerinin Değerlendirilmesi
Amaç: Romatoid artritli yetişkin hastalarda statik ve dinamik pupilla yanıtlarını sağlıklı yetişkinler ile karşılaştırmayı amaçladık. Yöntemler: Bu prospektif çalışmaya, oftalmoloj...

Back to Top