Can Syndesmosis Screws Displace the Distal Fibula?
View through CrossRef
Background. There has been historical debate as to whether the distal tibiofibular syndesmosis can be overtightened during operative fixation. We used finite-element analysis to determine if overtightening of syndesmotic screws can cause widening of the lateral gutter clear space in the ankle joint. Methods. A 3D finite-element model was constructed and analyzed using geometries from a computed tomography scan of a cadaveric lower leg. Starting 2 cm from the plafond, screw fixation was simulated at 5-mm increments to a distance of 5 cm from the plafond. The fibula was compressed 2 mm toward the tibia at each interval, and the change in distance between the lateral talus and distal fibula was measured. Results. Medial deflection of the fibula resulted in widening of the lateral clear space, which was proportional to the amount of deflection. The effect increased as screws were placed closer to the plafond, with 1.5 mm of widening at 2 cm (0.76 mm/mm) versus 0.7 mm at 5 cm (0.34 mm/mm). Conclusion. Our finite-element model demonstrated that overtightening of the distal tibiofibular syndesmosis with medial fibular displacement can cause widening of the lateral clear space. Clinical relevance. The results suggest that screws placed farther from the plafond widen the lateral clear space to a lesser degree, which may be advantageous during surgical fixation to prevent clear space widening and increased tibiotalar contact forces. Levels of Evidence: Level I
Title: Can Syndesmosis Screws Displace the Distal Fibula?
Description:
Background.
There has been historical debate as to whether the distal tibiofibular syndesmosis can be overtightened during operative fixation.
We used finite-element analysis to determine if overtightening of syndesmotic screws can cause widening of the lateral gutter clear space in the ankle joint.
Methods.
A 3D finite-element model was constructed and analyzed using geometries from a computed tomography scan of a cadaveric lower leg.
Starting 2 cm from the plafond, screw fixation was simulated at 5-mm increments to a distance of 5 cm from the plafond.
The fibula was compressed 2 mm toward the tibia at each interval, and the change in distance between the lateral talus and distal fibula was measured.
Results.
Medial deflection of the fibula resulted in widening of the lateral clear space, which was proportional to the amount of deflection.
The effect increased as screws were placed closer to the plafond, with 1.
5 mm of widening at 2 cm (0.
76 mm/mm) versus 0.
7 mm at 5 cm (0.
34 mm/mm).
Conclusion.
Our finite-element model demonstrated that overtightening of the distal tibiofibular syndesmosis with medial fibular displacement can cause widening of the lateral clear space.
Clinical relevance.
The results suggest that screws placed farther from the plafond widen the lateral clear space to a lesser degree, which may be advantageous during surgical fixation to prevent clear space widening and increased tibiotalar contact forces.
Levels of Evidence: Level I.
Related Results
Syndesmosis Instability
Syndesmosis Instability
The syndesmosis is one of important stabilizer of the ankle joint and consists of a complex ligamentous structure: the anterior inferior tibiofibular ligament; the interosseous lig...
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
ABSTRACT
Introduction
Syndesmotic injuries present a challenge to orthopedic surgeons. Malreduction of the syndesmosis has been reported to cause instability and secondary osteoar...
Defining the fit and ideal entry site of the fibula rod system––a computed tomography based study in elderly patients with lower limb infections, vascular diseases or tumors
Defining the fit and ideal entry site of the fibula rod system––a computed tomography based study in elderly patients with lower limb infections, vascular diseases or tumors
Objectives
To determine the configuration of the distal fibula anatomy and the fitness of the Fibula Rod System (Acumed®, Hillsboro, Oregon) in a series of fibu...
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
Morphometric analysis of paired fibula and mandible for optimal fibular mandibular reconstruction in a Chinese population
Morphometric analysis of paired fibula and mandible for optimal fibular mandibular reconstruction in a Chinese population
AbstractTo analyze the morphology of paired fibula and mandible aiming to choose optimal fibular segments for mandibular reconstruction in a Chinses population. A total of 118 case...
Removal of Syndesmal Screws: A Systematic Review
Removal of Syndesmal Screws: A Systematic Review
Background: Ankle fracture is quite common in the emergency. This can generate a rupture of the syndesmosis generating instability of the joint. The surgical treatment of syndesmos...
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
ObjectivesCement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of...
Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread
Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread
Abstract
Background
The influence of thread profile on the fixation stability of bone screws remains unclear. This study aimed to compare the fixati...