Javascript must be enabled to continue!
Effect of Ionic Presence on Chlorine Disinfection of Animal Viruses
View through CrossRef
Work by Scarpino in 1972 indicated that disinfection rates are affected by ionic presence. When disinfecting coxackievirus A9 with H0C1 at pH 6.0 in the presence of 0.05M KC1 the effect is to increase the disinfection rate 50 times. Disinfection of coxackievirus A9 at pH 10.0 shows that 0.05M KC1 increases the disinfection rate 10 times. This rate difference due to 0.05M KC1 between the two pH's may be due to the charge on the hypochlorite ion, the change of charge on the surface of the virion, or to a change in the chemical equilibrium of chlorine due to the pH. Studies with poliovirus 1 and 0.05M KC1 showed the same ion effect. When the disinfection of poliovirus 1 with hypochlorous acid (H0C1) was compared with the disinfection of E.coli, the E.coli was disinfected quicker than poliovirus 1. This relationship that viruses are more resistant than the fecal indicator organism E.coli is generally accepted. However, poliovirus 1 was more sensitive to hypochlorite ion (OCl−) than E. coli, when 0.05M KC1 was present in the buffer. Whereas the ion effect was present for coxsackievirus A9 and poliovirus 1, it was not present for E.coli.
We have been pursuing this ion effect phenomenon using both chlorine and chloramines. To determine whether this ion effect was present with chloramines, similar tests were run using monochloramine (NH2C1) as the disinfectant. Again the effect held. That is, the presence of KC1 in the buffers increased the efficiency of the disinfectant. This ion-effect was dose dependent between 0.05M KC1 and 0.1M KC1, where the effect was greater with 0.1M KC1. The OCl− and NH2C1 studies were both run at pH 10.0 and at 5°C. Tests were then run to determine whether the effect held for dichloramine (NHC12) at pH 4.5. The ion-effect was present using dichloramine. However, the level of dichloramine dropped from 11.5 ppm to 6.5 ppm during the test. The chloramine loss may be due to the shift of equilibrium as represented by the following equation:
With the formation of nitrogen tri-chloride (NC13) the ion-effect could be dissipated if the addition of KC1 was made at a different time. When the chlorine species was formed in the presence of KC1 the effect was present. When the KC1 was added to the already formed specie the effect was not present in the case of monochloramine and much reduced in the case of hypochlorous acid. Therefore, the time of the KC1 addition to the system was critical to the ion-effect phenomenon.
Title: Effect of Ionic Presence on Chlorine Disinfection of Animal Viruses
Description:
Work by Scarpino in 1972 indicated that disinfection rates are affected by ionic presence.
When disinfecting coxackievirus A9 with H0C1 at pH 6.
0 in the presence of 0.
05M KC1 the effect is to increase the disinfection rate 50 times.
Disinfection of coxackievirus A9 at pH 10.
0 shows that 0.
05M KC1 increases the disinfection rate 10 times.
This rate difference due to 0.
05M KC1 between the two pH's may be due to the charge on the hypochlorite ion, the change of charge on the surface of the virion, or to a change in the chemical equilibrium of chlorine due to the pH.
Studies with poliovirus 1 and 0.
05M KC1 showed the same ion effect.
When the disinfection of poliovirus 1 with hypochlorous acid (H0C1) was compared with the disinfection of E.
coli, the E.
coli was disinfected quicker than poliovirus 1.
This relationship that viruses are more resistant than the fecal indicator organism E.
coli is generally accepted.
However, poliovirus 1 was more sensitive to hypochlorite ion (OCl−) than E.
coli, when 0.
05M KC1 was present in the buffer.
Whereas the ion effect was present for coxsackievirus A9 and poliovirus 1, it was not present for E.
coli.
We have been pursuing this ion effect phenomenon using both chlorine and chloramines.
To determine whether this ion effect was present with chloramines, similar tests were run using monochloramine (NH2C1) as the disinfectant.
Again the effect held.
That is, the presence of KC1 in the buffers increased the efficiency of the disinfectant.
This ion-effect was dose dependent between 0.
05M KC1 and 0.
1M KC1, where the effect was greater with 0.
1M KC1.
The OCl− and NH2C1 studies were both run at pH 10.
0 and at 5°C.
Tests were then run to determine whether the effect held for dichloramine (NHC12) at pH 4.
5.
The ion-effect was present using dichloramine.
However, the level of dichloramine dropped from 11.
5 ppm to 6.
5 ppm during the test.
The chloramine loss may be due to the shift of equilibrium as represented by the following equation:
With the formation of nitrogen tri-chloride (NC13) the ion-effect could be dissipated if the addition of KC1 was made at a different time.
When the chlorine species was formed in the presence of KC1 the effect was present.
When the KC1 was added to the already formed specie the effect was not present in the case of monochloramine and much reduced in the case of hypochlorous acid.
Therefore, the time of the KC1 addition to the system was critical to the ion-effect phenomenon.
Related Results
Intratumoral Delivery of Chlorine Dioxide Exploits its ROS-like Properties: A Novel Paradigm for Effective Cancer Therapy
Intratumoral Delivery of Chlorine Dioxide Exploits its ROS-like Properties: A Novel Paradigm for Effective Cancer Therapy
Abstract
Our study underscores the potential of chlorine dioxide, resembling reactive oxygen species, in promoting tissue regeneration and executing similar functio...
Disposable Chlorine Sensor Based on Pencil Graphite Electrode
Disposable Chlorine Sensor Based on Pencil Graphite Electrode
Chlorine is widely used as a disinfectant in the water treatment industry for inactivation of pathogenic micro-organisms such as Cryptosporidium and Escherichia coli. Chlorine in a...
Evaluation of Disinfection Methods and Effects for Handwashing Sinks Contaminated with Pseudomonas aeruginosa
Evaluation of Disinfection Methods and Effects for Handwashing Sinks Contaminated with Pseudomonas aeruginosa
Abstract
Objective
To address the recurrent contamination of handwashing sinks with Pseudomonas aeruginosa (PA) in the Pediatri...
The Halogens
The Halogens
AbstractThe halogens are those elements in group XVII of the periodic table, and include fluorine, chlorine, bromine, iodine, and astatine, the latter of which is a radioactive ele...
Study on Shock Disinfection in a Fire Extinguishing Water Supply System
Study on Shock Disinfection in a Fire Extinguishing Water Supply System
The biofilms generated in a fire extinguishing water supply system can cause corrosion and a reduction in the water supply capacity; thus, degrading the system performance. To miti...
Comparison of Chlorine, Bromine, and Iodine as Disinfectants for Swimming Pool Water
Comparison of Chlorine, Bromine, and Iodine as Disinfectants for Swimming Pool Water
Studies on the germicidal activity of chlorine, bromine, and iodine were made by use of the Association of Official Agricultural Chemists official first action method for determini...
Comparison between constant and variable chlorine decay models applied to urban water supply network
Comparison between constant and variable chlorine decay models applied to urban water supply network
Abstract. Monitoring of chlorine residual in water distribution systems is necessary not only for ensuring potable water quality but also prevent emergence of disinfection by-produ...
Phylogenomic analysis of Uganda influenza type-A viruses to assess their relatedness to the vaccine strains and other Africa viruses: a molecular epidemiology study
Phylogenomic analysis of Uganda influenza type-A viruses to assess their relatedness to the vaccine strains and other Africa viruses: a molecular epidemiology study
ABSTRACT
Background
Genetic characterisation of circulating influenza viruses is essential for vaccine selection and mitigation...