Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial

View through CrossRef
Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic sleeves. Materials and methods: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled. Patients were randomized according to a parallel group design into two arms: Surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions. Results: No implants failed, and no complications were experienced. Forty-one implants were placed using surgical templates with metallic sleeves while 49 implants were placed with a surgical template without metallic sleeves. Of these, 16 implants were placed through open sleeves and 33 through closed sleeves. There was a statistically significant difference in angle (p = 0.0212) and in the vertical plan (p = 0.0073) with lower values for implants placed with a surgical template without metallic sleeves. In the test group, close sleeves were more accurate compared with open sleeves in angle (p = 0.0268) and in horizontal plan (p = 0.0477). Conclusion: With the limitations of the present study, surgical templates without metallic sleeves were more accurate in the vertical plan and angle compared to the conventional template with metallic sleeves. Open sleeves should be used with caution in the molar region only in case of reduced interarch space. Further research is needed to confirm these preliminary results.
Title: Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
Description:
Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves.
Furthermore, to compare open versus closed sleeves for templates without metallic sleeves.
Materials and methods: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled.
Patients were randomized according to a parallel group design into two arms: Surgical template with or without metallic sleeves.
Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions.
Results: No implants failed, and no complications were experienced.
Forty-one implants were placed using surgical templates with metallic sleeves while 49 implants were placed with a surgical template without metallic sleeves.
Of these, 16 implants were placed through open sleeves and 33 through closed sleeves.
There was a statistically significant difference in angle (p = 0.
0212) and in the vertical plan (p = 0.
0073) with lower values for implants placed with a surgical template without metallic sleeves.
In the test group, close sleeves were more accurate compared with open sleeves in angle (p = 0.
0268) and in horizontal plan (p = 0.
0477).
Conclusion: With the limitations of the present study, surgical templates without metallic sleeves were more accurate in the vertical plan and angle compared to the conventional template with metallic sleeves.
Open sleeves should be used with caution in the molar region only in case of reduced interarch space.
Further research is needed to confirm these preliminary results.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Deep-diffeomorphic networks for conditional brain templates
Deep-diffeomorphic networks for conditional brain templates
Abstract Deformable brain templates are an important tool in many neuroimaging analyses. Conditional templates (e.g., age-specific templates) hav...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...
Clinical Accuracy of Static Computer-Assisted Implant Surgery (sCAIS) for Single Implant Placement: An In Vivo Study
Clinical Accuracy of Static Computer-Assisted Implant Surgery (sCAIS) for Single Implant Placement: An In Vivo Study
Objective: The objective of the present study is to evaluate the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in single tooth implant placement by using formula met...

Back to Top