SU‐E‐T‐126: Non‐Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High‐Energy Photons
View through CrossRef
Purpose: To correct for the deviations of the detector response when typical radiation detectors are used under non‐reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phantom beneath a Siemens Primus 6/15 MV linac. A Farmer type ion chamber (NE2571), two TLD detector types and two diodes were investigated. Methods: Factor kNR was obtained as the ratio of the weighted responses Yt of a given detector t under reference conditions xref (axial distance r = 0 cm, depth d = 10 cm, field size 10 × 10 cm2 and SSD = 100 cm) and that under non‐reference conditions × (off‐axis points and depths for various field sizes); kNR = Yt(xref)/Yt(x). For small field (SF) dosimetry, we evaluated correction factor kNRSF, which refers to small field reference conditions (4 × 4 cm2 field). Results: For all detectors investigated, the deviations of kNR from unity were highest outside the field, due to prevailing low‐energy scatter contributions. For the Farmer chamber and EDP‐10 diode, the kNR deviations did not exceed 2%, but were up to 60% for the EDD‐5 diode, while kNR values for LiF:Mg,Cu,P and LiF:Mg,Ti deviated at most 15% and 5% respectively. kNR values appear as unique functions of the mean photon energy at the point of interest. Conclusions: Air‐filled ion chambers show only small kNR variations, while for non‐water equivalent detectors, kNR variations depend on the detector response at low photon energy. kNR can be presented as a unique function of the mean photon energy at the point of interest. A 4 × 4 cm2 reference field is recommended for small fields, with correction factor kNRSF varying almost negligibly from kNR except for unshielded Si diodes.
Title: SU‐E‐T‐126: Non‐Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High‐Energy Photons
Description:
Purpose: To correct for the deviations of the detector response when typical radiation detectors are used under non‐reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phantom beneath a Siemens Primus 6/15 MV linac.
A Farmer type ion chamber (NE2571), two TLD detector types and two diodes were investigated.
Methods: Factor kNR was obtained as the ratio of the weighted responses Yt of a given detector t under reference conditions xref (axial distance r = 0 cm, depth d = 10 cm, field size 10 × 10 cm2 and SSD = 100 cm) and that under non‐reference conditions × (off‐axis points and depths for various field sizes); kNR = Yt(xref)/Yt(x).
For small field (SF) dosimetry, we evaluated correction factor kNRSF, which refers to small field reference conditions (4 × 4 cm2 field).
Results: For all detectors investigated, the deviations of kNR from unity were highest outside the field, due to prevailing low‐energy scatter contributions.
For the Farmer chamber and EDP‐10 diode, the kNR deviations did not exceed 2%, but were up to 60% for the EDD‐5 diode, while kNR values for LiF:Mg,Cu,P and LiF:Mg,Ti deviated at most 15% and 5% respectively.
kNR values appear as unique functions of the mean photon energy at the point of interest.
Conclusions: Air‐filled ion chambers show only small kNR variations, while for non‐water equivalent detectors, kNR variations depend on the detector response at low photon energy.
kNR can be presented as a unique function of the mean photon energy at the point of interest.
A 4 × 4 cm2 reference field is recommended for small fields, with correction factor kNRSF varying almost negligibly from kNR except for unshielded Si diodes.
Related Results
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
<em><span id="page3R_mcid52" class="markedContent"><span style="left: calc(var(--scale-factor)*125.30px); top: calc(var(--scale-factor)*539.11px); font-size: calc(va...
(Gen)udsendelse af grønlandsk kultur, sprog og historie.
(Gen)udsendelse af grønlandsk kultur, sprog og historie.
2023 marks a milestone in the history of Greenlandic media. It is both the 41st anniversary of the first tv-programs broadcast to a Greenlandic audience in the Greenlandic language...
Multi-photon quantum interference and entanglement
Multi-photon quantum interference and entanglement
Interférence et intrication quantiques à plusieurs photons
Dans cette thèse de doctorat, nous étudions des caractéristiques clés du traitement optique de l'informat...
Technologies for retrospective radiation dosimetry
Technologies for retrospective radiation dosimetry
Abstract
Radiation dosimetry is an important task for assessing the biological damages created in human being due to ionising radiation exposure. Ionising radiation ...
Overview of Technologies Implemented During the First Wave of the COVID-19 Pandemic: Scoping Review (Preprint)
Overview of Technologies Implemented During the First Wave of the COVID-19 Pandemic: Scoping Review (Preprint)
BACKGROUND
Technologies have been extensively implemented to provide health care services for all types of clinical conditions during the COVID-19 pandemic....
Feasibility study of shielded diode detector for small field dosimetry
Feasibility study of shielded diode detector for small field dosimetry
Abstract
Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitat...
Time dilation: A consequence of the speed of light variation
Time dilation: A consequence of the speed of light variation
The escape speed from one point-mass M1 is u1 = (−2u1)½ with u1 (= −M1G/s1) the (Newtonian) gravitational potential energy and
s1 the distance between M1 and a chosen point. Obser...
Etched Track Techniques in Radiation Dosimetry
Etched Track Techniques in Radiation Dosimetry
Abstract
Conventional detectors used in radiation protection dosimetry (for a given amount of energy deposited in their macroscopic volumes) are most sensitive to...