Finite element analysis of deterioration of axial compression behavior of corroded steel-reinforced concrete middle-length columns

View through CrossRef
Abstract The corrosion problem of steel-reinforced concrete (SRC) columns in coastal areas is becoming increasingly severe and needs to be solved urgently. This study established a numerical analysis model for SRC middle-length columns considering corrosion effects. The bond–slip constitutive relationship between corroded steel and concrete was established. It was found that when the rust rate is low, the bonding stress of SRC columns is slightly increased compared to those without corrosion. The ultimate and residual bonding stress will decrease significantly when the rust rate exceeds 1.5%. The comparison between the numerical analysis model and the experimental results shows that the establishment of the model is reasonable. Subsequent parameter analysis showed that for corroded SRC mid-length columns, the larger the slenderness ratio of the component, the faster the decrease in axial compression performance. The rust rate increased from 0 to 30%, and the axial compression performance of SRC columns decreased significantly. When the rust rate exceeded 30%, the axial compression performance of concrete columns tended to stabilize. A formula for calculating SRC middle-length columns’ ultimate bearing capacity considering corrosion effects has been proposed.
Title: Finite element analysis of deterioration of axial compression behavior of corroded steel-reinforced concrete middle-length columns
Description:
Abstract The corrosion problem of steel-reinforced concrete (SRC) columns in coastal areas is becoming increasingly severe and needs to be solved urgently.
This study established a numerical analysis model for SRC middle-length columns considering corrosion effects.
The bond–slip constitutive relationship between corroded steel and concrete was established.
It was found that when the rust rate is low, the bonding stress of SRC columns is slightly increased compared to those without corrosion.
The ultimate and residual bonding stress will decrease significantly when the rust rate exceeds 1.
5%.
The comparison between the numerical analysis model and the experimental results shows that the establishment of the model is reasonable.
Subsequent parameter analysis showed that for corroded SRC mid-length columns, the larger the slenderness ratio of the component, the faster the decrease in axial compression performance.
The rust rate increased from 0 to 30%, and the axial compression performance of SRC columns decreased significantly.
When the rust rate exceeded 30%, the axial compression performance of concrete columns tended to stabilize.
A formula for calculating SRC middle-length columns’ ultimate bearing capacity considering corrosion effects has been proposed.

Related Results

Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Abstract Axial compression performance of concrete columns reinforced with 2304 duplex stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel c...
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Abstract Axial compression performance of concrete columns reinforced with 2304 solid stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel cl...
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Abstract The research aims to study the behaviour of concrete columns reinforced with fibreglass as bars exposed to seawater. Firstly, hardened concrete properties a...
Influence of axial compression ratio in building columns
Influence of axial compression ratio in building columns
(English) Axial forces in columns of moment-resisting frames (MRF) have a paramount role for the seismic performance of these structural systems. Nonetheless, there are significan...
Fire Behaviour and Design of Square Steel Tube Confined Reinforced Concrete Columns: Isolated Columns to Framed Columns
Fire Behaviour and Design of Square Steel Tube Confined Reinforced Concrete Columns: Isolated Columns to Framed Columns
The steel tube confined reinforced concrete (STCRC) column, is an innovate type of steel-concrete composite column comprising an outer thin-walled steel tube that does not bear axi...
Simulation of flexural performance of mill-cut steel fiber reinforced concrete beam degraded by mild corrosion
Simulation of flexural performance of mill-cut steel fiber reinforced concrete beam degraded by mild corrosion
The reinforced concrete structure is widely used for various applications structure due to its many advantages, so it is easily exposed to severe environments and corrosion of stee...
Steel fiber concrete. Constructions. Terminology
Steel fiber concrete. Constructions. Terminology
The article discusses the terms and definitions that are increasingly appearing in the open press and on the Internet, confusing well-established concepts. The purpose of consideri...
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
ABSTRACT In order to develop an optimum steel/concrete composite ice wall for the arctic offshore structures, structural behavior of the steel/concrete composite ...