Javascript must be enabled to continue!
Shear Bond Strength of a Mechanically Retained Ceramic Bracket
View through CrossRef
Abstract
The failure under shear loading of mechanically retained ceramic brackets bonded to enamel was investigated.
One light-activated dual-cure and two no-mix self-cure adhesives were compared to au Adhesive Pre-coated hracket (APC).
The results indicated that the ceramic bracket bonded with the light-activated dual-cure adhesive had a significantly higher mean shear bond strength than the other adhesive systems.
All adhesive systems usually failed cohesively with adhesive remaining attached to the bracket and enamel surfaces. There was no significant difference in failure site.
There was a significant difference in the amount of adhesive remaining attached to the enamel surface. The light-activated dual-cure adhesive and Adhesive Pre-coated brackets failed in 50% and 80% of instances respectively, with less than 10% of the adhesive remaining attached to the enamel surface. Self-cure adhesives failed usually with 10-90% of the adhesive remaining attached to the enamel surface. There were no instances of enamel damage. Three cases of bracket fracture occurred, one of these being associated with the highest recorded bond strength.
Title: Shear Bond Strength of a Mechanically Retained Ceramic Bracket
Description:
Abstract
The failure under shear loading of mechanically retained ceramic brackets bonded to enamel was investigated.
One light-activated dual-cure and two no-mix self-cure adhesives were compared to au Adhesive Pre-coated hracket (APC).
The results indicated that the ceramic bracket bonded with the light-activated dual-cure adhesive had a significantly higher mean shear bond strength than the other adhesive systems.
All adhesive systems usually failed cohesively with adhesive remaining attached to the bracket and enamel surfaces.
There was no significant difference in failure site.
There was a significant difference in the amount of adhesive remaining attached to the enamel surface.
The light-activated dual-cure adhesive and Adhesive Pre-coated brackets failed in 50% and 80% of instances respectively, with less than 10% of the adhesive remaining attached to the enamel surface.
Self-cure adhesives failed usually with 10-90% of the adhesive remaining attached to the enamel surface.
There were no instances of enamel damage.
Three cases of bracket fracture occurred, one of these being associated with the highest recorded bond strength.
Related Results
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
One of the problems that often occurred during orthodontic treatment is bracket failure. This is usually the result either of the patient’s accidentally, applying inappropriate for...
Effect of Ceramic Surface Treatment and Adhesive Systems on Bond Strength of Metallic Brackets
Effect of Ceramic Surface Treatment and Adhesive Systems on Bond Strength of Metallic Brackets
Objective. This study evaluated the effect of ceramic surface treatments on bond strength of metal brackets to machinable ceramics and veneering porcelain using different adhesive ...
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Introduction: The debonding of brackets is common in orthodontic practice. It may be due to bond failure or as a need for bracket repositioning. Typically practitioners shall disca...
Effects of bracket design on critical contact angle
Effects of bracket design on critical contact angle
ABSTRACT
Objective:
To explore how the position of the bracket slots relative to the archwire influences the friction between them, and how bracket des...
Evaluation of shear bond strength of orthodontic resin and resin modified glass ionomer cement on bonding of metal and ceramic brackets
Evaluation of shear bond strength of orthodontic resin and resin modified glass ionomer cement on bonding of metal and ceramic brackets
The aim of this study was to evaluate the shear bond strength of orthodontic resin and resin-modified glass ionomer cement on bonding of metal and ceramic brackets. Material and me...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...
Ceramometal Bond Strength Analysis using New and Recast Nonprecious Alloys with Three Different Ceramics
Ceramometal Bond Strength Analysis using New and Recast Nonprecious Alloys with Three Different Ceramics
ABSTRACT
Objectives
This study is undertaken to evaluate the dependence of bond strength of 100% fresh nonprecious alloy and the combination of 50% recast (used) alloy and 50% fre...

