Javascript must be enabled to continue!
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery
View through CrossRef
AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.
METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA).
RESULTS: Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed.
CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.
Press of International Journal of Ophthalmology (IJO Press)
Title: Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery
Description:
AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.
METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D).
A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes.
The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA).
RESULTS: Preoperative refractive astigmatism was 2.
14±1.
17 D, which was significantly reduced to 0.
77±0.
37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.
67±0.
44 D at three months and 0.
75±0.
25 D at six months; for all groups: P<0.
0001 compared to baseline).
BCVA improved significantly from 0.
36±0.
33 logMAR preoperatively to 0.
10±0.
15 logMAR following surgery (P=0.
02).
Mean IOL axis deviation from the target axis was 3.
4°±2.
9° after six to eight weeks and significantly decreased over time (2.
4°±2.
6° six months after surgery; P=0.
04).
In one patient IOL, re-alignment was performed.
CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.
The plate haptic toric IOL position and axis remain stable during the observation period of six months.
Related Results
Quantum gauge theory simulation with ultracold atoms
Quantum gauge theory simulation with ultracold atoms
The study of ultracold atoms constitutes one of the hottest areas of atomic, molecular, and optical physics and quantum optics. The experimental and theoretical achievements in the...
Refractive Outcomes of Combined Cataract Surgery and Vitrectomy Compared to Cataract Surgery Alone
Refractive Outcomes of Combined Cataract Surgery and Vitrectomy Compared to Cataract Surgery Alone
Purpose: The aim of the study was to evaluate the refractive outcomes of combined cataract surgery and vitrectomy compared to cataract surgery alone. Methods: This retrospective ch...
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
PurposeThis study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experi...
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Purpose: To compare toric IOL (Intra Ocular Lenses) suggestions for power, toric, and IOL alignment between the IOLMaster 700 and Pentacam AXL (Axial Length).
Methods: This single-...
Long-term Astigmatism Reduction with Toric Intraocular Lenses – A Systematic Review.
Long-term Astigmatism Reduction with Toric Intraocular Lenses – A Systematic Review.
Topic:
This study aimed to assess the long-term effectiveness of toric intraocular lenses (IOL) in reducing refractive astigmatism at and beyond one year, along...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism.
Methods: 31 eyes of 31 patie...

