Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Research of Turbine Oil Varnish in Generator Unit

View through CrossRef
Abstract In recent years, due to the fact that thermal power generating units have been deeply involved in the peak shaving work of the power grid, the frequent start and stop operations of the units and rapid load-carrying operations have made the operating conditions of the units very bad. In large-scale thermal power generation units, shutdown accidents caused by varnish failures are becoming more common. Take the serious varnish failure of Unit 3 in a domestic power plant as a case for analysis. The steam turbine oil after the varnish is formed is fully analyzed and tested and the metal ion content test is carried out. The changes in the physical indicators of the steam turbine oil during the formation of the varnish are studied to determine the influence of the steam turbine oil on the physical indicators of the steam turbine oil during the formation of the steam turbine oil. The operation and maintenance personnel can detect the varnish in advance through the daily sampling and analysis of the steam turbine oil, and timely take treatment measures to remove the varnish components in the oil to ensure the safe and stable operation of the unit. This article summarizes the reason for the formation of varnish and the detection method of varnish. It is of great significance to effectively discover and control the production of varnish during the operation of the generator set, to study the formation mechanism of varnish and to find an effective method to remove varnish. This article also introduces the commonly used paint film treatment methods for the convenience of electric power technicians.
Title: Research of Turbine Oil Varnish in Generator Unit
Description:
Abstract In recent years, due to the fact that thermal power generating units have been deeply involved in the peak shaving work of the power grid, the frequent start and stop operations of the units and rapid load-carrying operations have made the operating conditions of the units very bad.
In large-scale thermal power generation units, shutdown accidents caused by varnish failures are becoming more common.
Take the serious varnish failure of Unit 3 in a domestic power plant as a case for analysis.
The steam turbine oil after the varnish is formed is fully analyzed and tested and the metal ion content test is carried out.
The changes in the physical indicators of the steam turbine oil during the formation of the varnish are studied to determine the influence of the steam turbine oil on the physical indicators of the steam turbine oil during the formation of the steam turbine oil.
The operation and maintenance personnel can detect the varnish in advance through the daily sampling and analysis of the steam turbine oil, and timely take treatment measures to remove the varnish components in the oil to ensure the safe and stable operation of the unit.
This article summarizes the reason for the formation of varnish and the detection method of varnish.
It is of great significance to effectively discover and control the production of varnish during the operation of the generator set, to study the formation mechanism of varnish and to find an effective method to remove varnish.
This article also introduces the commonly used paint film treatment methods for the convenience of electric power technicians.

Related Results

STUDI ANALISIS EFISIENSI STEAM TURBINE GENERATOR PADA BAGIAN ASAM SULFAT DAN UTILITAS DEPARTEMEN PRODUKSI IIIB PT PETROKIMIA GRESIK
STUDI ANALISIS EFISIENSI STEAM TURBINE GENERATOR PADA BAGIAN ASAM SULFAT DAN UTILITAS DEPARTEMEN PRODUKSI IIIB PT PETROKIMIA GRESIK
Sejumlah energi penggerak peralatan proses sangat diperlukan dalam proses produksi di seluruh pabrik yang ada pada PT Petrokimia Gresik. Departemen Produksi IIIB memiliki unit util...
A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
Abstract The main causes of gas turbine performance degradation in natural gas combined cycle power plants are corrosion, fouling, and high turbine inlet temperature...
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
This paper presents an experimental study of the impact of individual high-pressure turbine purge flows on the main flow in a downstream turbine center frame duct. Measurements wer...
Aeroderivative Gas Turbine Coupling Generator Redesign
Aeroderivative Gas Turbine Coupling Generator Redesign
A major failure event was experienced at a 44 MW plant powered by four aeroderivative gas turbines arranged in two units, property of the Federal Commission of Electricity (CFE). ...
Manganese Accumulation in Rock Varnish on a Desert Piedmont, Mojave Desert, California, and Application to Evaluating Varnish Development
Manganese Accumulation in Rock Varnish on a Desert Piedmont, Mojave Desert, California, and Application to Evaluating Varnish Development
AbstractRock varnish coatings tend to become thicker, darker, and more continuous over time, leading to the use of changes in overall varnish color and the percentage of clast surf...
In Vitro Biocompatibility of CPP-ACP and Fluoride-containing Desensitizers on Human Gingival Cells
In Vitro Biocompatibility of CPP-ACP and Fluoride-containing Desensitizers on Human Gingival Cells
SUMMARY Objectives To analyze the biocompatibility of different desensitizers containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) an...
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Gas turbine technology trends to be maturing now, but the problem of which not being able to reverse directly remains resolve. In the field of marine, most ships reverse by adjusta...

Back to Top