Nonlinear static analysis and stability of a three-dimensional guyed truss tower considering the unilateral contact of the stays

View through CrossRef
Guyed towers are widely used in various engineering applications, such as telecommunications, broadcasting, and power transmission, due to their slender geometry, favorable structural performance under service loads, and economic efficiency. However, numerous structural failures resulting in tower collapse are often associated with stay cable rupture or malfunction. In this context, the present work investigates the nonlinear static equilibrium and structural stability of a three-dimensional guyed truss tower, taking into account the hypothesis of unilateral contact in the stays. To achieve this, a positional formulation combined with the Euler–Lagrange equations is employed to derive a set of nonlinear second-order ordinary differential equations that describe the structural behavior of the guyed tower. This nonlinear system is then solved to obtain equilibrium paths and assess their stability under two practical loading scenarios: (i) the guyed tower subjected to vertical loads, and (ii) the guyed tower subjected to horizontal loads. Particular emphasis is placed on the influence of unilateral contact in the stays on the nonlinear equilibrium path, which reveals a complex bifurcation and stability scenario arising from this critical assumption regarding stay behavior.
Title: Nonlinear static analysis and stability of a three-dimensional guyed truss tower considering the unilateral contact of the stays
Description:
Guyed towers are widely used in various engineering applications, such as telecommunications, broadcasting, and power transmission, due to their slender geometry, favorable structural performance under service loads, and economic efficiency.
However, numerous structural failures resulting in tower collapse are often associated with stay cable rupture or malfunction.
In this context, the present work investigates the nonlinear static equilibrium and structural stability of a three-dimensional guyed truss tower, taking into account the hypothesis of unilateral contact in the stays.
To achieve this, a positional formulation combined with the Euler–Lagrange equations is employed to derive a set of nonlinear second-order ordinary differential equations that describe the structural behavior of the guyed tower.
This nonlinear system is then solved to obtain equilibrium paths and assess their stability under two practical loading scenarios: (i) the guyed tower subjected to vertical loads, and (ii) the guyed tower subjected to horizontal loads.
Particular emphasis is placed on the influence of unilateral contact in the stays on the nonlinear equilibrium path, which reveals a complex bifurcation and stability scenario arising from this critical assumption regarding stay behavior.

Related Results

Lena Guyed Tower Project Overview
Lena Guyed Tower Project Overview
ABSTRACT The installation of the Lena guyed tower was one of the industry's most significant accomplishments of 1983. This paper serves as an introduction to a se...
Structural Optimization and Experimental Research of High-rise Guyed Tower
Structural Optimization and Experimental Research of High-rise Guyed Tower
In this paper, the structural optimization of high-rise guyed tower is carried out for the guyed wire and tower column schemes. The schemes are compared from the four guyed wires a...
Design of the Lena Guyed Tower
Design of the Lena Guyed Tower
ABSTRACT The 1983 Lena platform installation in 1000 feet of water in the Gulf of Mexico culminated twelve years of guyed tower development. During the Lena desig...
ANALISIS PERBANDINGAN STRUKTUR ATAP LENGKUNG DENGAN SISTEM PRATT TRUSS DAN BOWSTRING TRUSS
ANALISIS PERBANDINGAN STRUKTUR ATAP LENGKUNG DENGAN SISTEM PRATT TRUSS DAN BOWSTRING TRUSS
Penggunaan struktur atap lengkung untuk bangunan bentang besar memerlukan sistem struktur rangka batang untuk penyusunnya. Sistem struktur yang umum digunakan untuk struktur atap l...
Roof truss systems under blast loads
Roof truss systems under blast loads
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] Designing roof systems for blast loading is quite complex. Many uncertainties still exist in this vital resea...
Lena Guyed Tower Decommissioning Engineering
Lena Guyed Tower Decommissioning Engineering
Abstract The Mississippi Canyon 280-A platform, also known as Lena Guyed Tower located in 1,000 ft water depth in the Gulf of Mexico (GoM), was successfully decommis...
Economical Aspect of Truss Design Through Geometry Configuration
Economical Aspect of Truss Design Through Geometry Configuration
In engineering, truss structures are used extensively in bridge, tower, building, and numerous mechanical applications. Several studies have found that truss frames use the least s...
Efficient Sizing and Layout Optimization of Truss Benchmark Structures Using ISRES Algorithm
Efficient Sizing and Layout Optimization of Truss Benchmark Structures Using ISRES Algorithm
This paper presents a comprehensive investigation into the application of the Improved Stochastic Ranking Evolution Strategy (ISRES) algorithm for the sizing and layout optimizatio...