Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

BIOMECHANICAL OPTIMIZATION OF IMPLANT-SUPPORTED PROSTHETIC REHABILITATION: EVIDENCE FROM FINITE ELEMENT ANALYSIS.

View through CrossRef
Background: Implant-supported prosthetic rehabilitation involves complex biomechanical interactions in which stress distribution is governed by implant design, restorative materials, prosthetic configuration, and the condition of supporting tissues. Direct clinical assessment of internal stress remains limited; therefore, finite element analysis (FEA) has become a key tool for investigating these relationships. Objective: To synthesize current finite element evidence and evaluate how implant geometry, material properties, prosthetic design, and clinical scenarios influence biomechanical performance in implant-supported prostheses. Methods: A focused narrative review of published three-dimensional FEA studies was conducted. Evidence was analyzed thematically, with emphasis on implant macrodesign, framework and superstructure materials, implant positioning, and prosthetic configurations across clinically relevant scenarios, including short implants in D4 bone, zygomatic implant rehabilitation, socket shield techniques, implant-assisted removable partial dentures, and mandibular full-arch prostheses. Primary outcomes included von Mises stress, strain, displacement, and micromovement. Results:Across the reviewed studies, implant macrodesign significantly influenced peri-implant biomechanics, particularly in compromised bone. Wider platform-switched short implants and square thread geometries consistently reduced stress, strain, and micromovement. Framework material stiffness also played a critical role: rigid materials such as zirconia, cobalt–chromium, and titanium decreased stress within implants and prosthetic components, whereas more flexible materials increased load transfer to these structures. In full-arch models, graphene frameworks demonstrated lower peri-implant stress compared with titanium. Implant positioning in distal-extension removable partial dentures showed comparable biomechanical behavior between premolar and molar sites. In socket shield models, increasing root fragment thickness led to progressive increases in stress and strain in both the retained root and surrounding bone. Conclusions: Biomechanical performance in implant-supported prosthetic rehabilitation is governed by the combined interaction of implant geometry, material stiffness, prosthetic design, and anatomical context rather than by any single factor. Finite element analysis provides valuable comparative insight into stress distribution patterns and supports more informed, biomechanics-driven treatment planning in implant prosthodontics.
Title: BIOMECHANICAL OPTIMIZATION OF IMPLANT-SUPPORTED PROSTHETIC REHABILITATION: EVIDENCE FROM FINITE ELEMENT ANALYSIS.
Description:
Background: Implant-supported prosthetic rehabilitation involves complex biomechanical interactions in which stress distribution is governed by implant design, restorative materials, prosthetic configuration, and the condition of supporting tissues.
Direct clinical assessment of internal stress remains limited; therefore, finite element analysis (FEA) has become a key tool for investigating these relationships.
Objective: To synthesize current finite element evidence and evaluate how implant geometry, material properties, prosthetic design, and clinical scenarios influence biomechanical performance in implant-supported prostheses.
Methods: A focused narrative review of published three-dimensional FEA studies was conducted.
Evidence was analyzed thematically, with emphasis on implant macrodesign, framework and superstructure materials, implant positioning, and prosthetic configurations across clinically relevant scenarios, including short implants in D4 bone, zygomatic implant rehabilitation, socket shield techniques, implant-assisted removable partial dentures, and mandibular full-arch prostheses.
Primary outcomes included von Mises stress, strain, displacement, and micromovement.
Results:Across the reviewed studies, implant macrodesign significantly influenced peri-implant biomechanics, particularly in compromised bone.
Wider platform-switched short implants and square thread geometries consistently reduced stress, strain, and micromovement.
Framework material stiffness also played a critical role: rigid materials such as zirconia, cobalt–chromium, and titanium decreased stress within implants and prosthetic components, whereas more flexible materials increased load transfer to these structures.
In full-arch models, graphene frameworks demonstrated lower peri-implant stress compared with titanium.
Implant positioning in distal-extension removable partial dentures showed comparable biomechanical behavior between premolar and molar sites.
In socket shield models, increasing root fragment thickness led to progressive increases in stress and strain in both the retained root and surrounding bone.
Conclusions: Biomechanical performance in implant-supported prosthetic rehabilitation is governed by the combined interaction of implant geometry, material stiffness, prosthetic design, and anatomical context rather than by any single factor.
Finite element analysis provides valuable comparative insight into stress distribution patterns and supports more informed, biomechanics-driven treatment planning in implant prosthodontics.

Related Results

Advanced engineering materials and materials processing technologies in dental implant and prosthetic treatment with clinical cases
Advanced engineering materials and materials processing technologies in dental implant and prosthetic treatment with clinical cases
The article deals with materials science issues concerning the application areas in dental engineering. The monograph aims to present the results of the Author’s work against the b...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Clinical–Biological Assessment of Prosthetic Field Following Pre-Prosthetic Phase Related to Prosthetic Treatment Solutions
Clinical–Biological Assessment of Prosthetic Field Following Pre-Prosthetic Phase Related to Prosthetic Treatment Solutions
Background. Extensive partial edentulism alters the biological and functional balance of the stomatognathic system, requiring targeted pre-prosthetic procedures to optimize treatme...
Soft tissue reconstructive techniques at implant sites
Soft tissue reconstructive techniques at implant sites
Dental implants have shown to be a reliable tool for single, multiple and full-arch rehabilitations 1. Dental implants have a very high success rate in terms of osseointegration, h...
A Comparative Study of Marginal Bone Loss in Immediate versus Delayed Implant Placement: A Longitudinal Analysis
A Comparative Study of Marginal Bone Loss in Immediate versus Delayed Implant Placement: A Longitudinal Analysis
Introduction: The timing of dental implant placement – whether immediate after tooth extraction or delayed after a healing period – remains debatable. Immediate...

Back to Top