Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Effect of Implant Length and Bone Quality on the Biomechanical Responses of Dental Implant and Surrounding Bone – A Three-Dimensional Finite Element Analysis

View through CrossRef
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads. These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed. The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone. As of now, the influence of implant length and bone quality on the surrounding tissues and the stability of implant structure continues to be a matter of debate and uncertainty, particularly in situations involving the possibility of implant failure. This study employed three-dimensional finite element analysis to investigate five distinct implant lengths (4, 6, 10, 13, and 15 mm) in two types of bone quality (type II and III). The bone tissues were characterized through the utilization of computed tomography image datasets and then underwent processing within the SolidWorks software. All geometric configurations were transformed into finite element models, which were subjected to analysis within the ANSYS software. Anisotropic and isotropic properties were attributed to the bone and implant models, respectively. A dynamic occlusal loading quantified at 300 N was applied to the implant body, accompanied by a pre-tension force of 20 N on the screw component. The longer implants exhibited decreased stress magnitudes in type II bone (87.86 – 36.66 MPa) and increased stress magnitudes in type III bone (80.5 – 2128.9 MPa) within the surrounding bone tissue, in comparison to the shorter implants. However, stress within the implant body was generally elevated with the use of longer implants in both bone types (type II: 505.32 – 625.35 MPa; type III: 500.45 – 2186.7 MPa). Irrespective of bone quality, the longer implants predominantly led to lower bone strain levels (type II: 0.006828 – 0.003328; type III: 0.054250 – 0.021678) and overall deformation of the implant-abutment assembly (type II: 0.1458 – 0.1348 μm; type III: 0.1754 – 0.1492 μm) compared to their shorter counterparts. Among all the assessed findings, type III bone displayed a more pronounced adverse impact on the biomechanical responses of the dental implant and neighbouring bone except for the implant stresses under the applied physiological loading.
Title: The Effect of Implant Length and Bone Quality on the Biomechanical Responses of Dental Implant and Surrounding Bone – A Three-Dimensional Finite Element Analysis
Description:
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads.
These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed.
The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone.
As of now, the influence of implant length and bone quality on the surrounding tissues and the stability of implant structure continues to be a matter of debate and uncertainty, particularly in situations involving the possibility of implant failure.
This study employed three-dimensional finite element analysis to investigate five distinct implant lengths (4, 6, 10, 13, and 15 mm) in two types of bone quality (type II and III).
The bone tissues were characterized through the utilization of computed tomography image datasets and then underwent processing within the SolidWorks software.
All geometric configurations were transformed into finite element models, which were subjected to analysis within the ANSYS software.
Anisotropic and isotropic properties were attributed to the bone and implant models, respectively.
A dynamic occlusal loading quantified at 300 N was applied to the implant body, accompanied by a pre-tension force of 20 N on the screw component.
The longer implants exhibited decreased stress magnitudes in type II bone (87.
86 – 36.
66 MPa) and increased stress magnitudes in type III bone (80.
5 – 2128.
9 MPa) within the surrounding bone tissue, in comparison to the shorter implants.
However, stress within the implant body was generally elevated with the use of longer implants in both bone types (type II: 505.
32 – 625.
35 MPa; type III: 500.
45 – 2186.
7 MPa).
Irrespective of bone quality, the longer implants predominantly led to lower bone strain levels (type II: 0.
006828 – 0.
003328; type III: 0.
054250 – 0.
021678) and overall deformation of the implant-abutment assembly (type II: 0.
1458 – 0.
1348 μm; type III: 0.
1754 – 0.
1492 μm) compared to their shorter counterparts.
Among all the assessed findings, type III bone displayed a more pronounced adverse impact on the biomechanical responses of the dental implant and neighbouring bone except for the implant stresses under the applied physiological loading.

Related Results

Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
TITLE: Awareness of dental personnel towards occupational injury- a cross sectional study ABSTRACT Objective: To determine the awareness of dental personnel towards dental occup...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Stress and Strain Studies of Different Materials of the Dental Implant in Single Implant-Supported Prosthesis: A Finite Element Analysis
Stress and Strain Studies of Different Materials of the Dental Implant in Single Implant-Supported Prosthesis: A Finite Element Analysis
Background and Objective: The elastic modulus of carbon fiber reinforced polyetheretherketone is close to that of bone tissue and has proven to be an excellent substitute for titan...
Techniques to Remove Press-Fit Osseointegration Implants
Techniques to Remove Press-Fit Osseointegration Implants
Background: Transcutaneous osseointegration for amputees (TOFA) has proven to consistently, significantly improve the quality of life and...

Back to Top