Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation and Analysis of Green Refrigerant Zero ODP as an Alternative Refrigerant Lower Cost and GWP

View through CrossRef
Abstract This research presents the results of investigation and analysis of the environmentally friendly refrigerant for R22 replacement. All refrigerant properties in this research were based on results from the REFPROP and CYCLE_D-HX software of NIST under CAN/ANSI/AHRI540. The results of this work show that HCs R170, R290, R600, R600a, R601, R601a, R1150 and R1270 can be mixed in HFCs R417A, R417B, R422A, R422B, R422C, R422D, R424A, R437A, R438A and R453A and able to be further developed in the future. All refrigerants are non-flammable refrigerants, non-toxic and zero ODP. The R453A mixed with HCs R600 (0.6%) and R601a (0.6%) and is COPc refrigerant close to that of R22 refrigerant. In conclusion, it can be used as an environmentally friendly and energy efficiency replacement for R22. All refrigerants are also refrigerants that are matched with the 4th generation refrigerants with the use of natural refrigerants.
Title: Investigation and Analysis of Green Refrigerant Zero ODP as an Alternative Refrigerant Lower Cost and GWP
Description:
Abstract This research presents the results of investigation and analysis of the environmentally friendly refrigerant for R22 replacement.
All refrigerant properties in this research were based on results from the REFPROP and CYCLE_D-HX software of NIST under CAN/ANSI/AHRI540.
The results of this work show that HCs R170, R290, R600, R600a, R601, R601a, R1150 and R1270 can be mixed in HFCs R417A, R417B, R422A, R422B, R422C, R422D, R424A, R437A, R438A and R453A and able to be further developed in the future.
All refrigerants are non-flammable refrigerants, non-toxic and zero ODP.
The R453A mixed with HCs R600 (0.
6%) and R601a (0.
6%) and is COPc refrigerant close to that of R22 refrigerant.
In conclusion, it can be used as an environmentally friendly and energy efficiency replacement for R22.
All refrigerants are also refrigerants that are matched with the 4th generation refrigerants with the use of natural refrigerants.

Related Results

Groundwater potential mapping in semi-arid region of Northern Nigeria by integrating analytic hierarchy process and GIS
Groundwater potential mapping in semi-arid region of Northern Nigeria by integrating analytic hierarchy process and GIS
Groundwater resource management in drylands, characterized by climate variability and population growth, is difficult. Exploration and exploitation of groundwater, due to inadequat...
Analisis Chiller Dengan Menggunaan R123 Dan R134a Pada Kinerja Pendinginan
Analisis Chiller Dengan Menggunaan R123 Dan R134a Pada Kinerja Pendinginan
AbstrakChiller adalah mesin refrigerasi yang memiliki fungsi utama mendinginkan air pada sisi evaporator, air yang didinginkan selanjutnya didistribusi ke alat penukar kalor (FCU; ...
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
Towards advanced sustainable technologies for asphalt pavement materials
Towards advanced sustainable technologies for asphalt pavement materials
The transportation sector remains one of the largest contributors to the greenhouse gas emissions in the United States, per economic sector, accounting for 28 percent of the total ...
Minimally Invasive Versus Open Distal Pancreatectomy (LEOPARD)
Minimally Invasive Versus Open Distal Pancreatectomy (LEOPARD)
Objective: This trial followed a structured nationwide training program in minimally invasive distal pancreatectomy (MIDP), according to the IDEAL framework for...
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refr...
Evaluating Eco-Friendly Refrigerant Alternatives for Cascade Refrigeration Systems: A Thermoeconomic Analysis
Evaluating Eco-Friendly Refrigerant Alternatives for Cascade Refrigeration Systems: A Thermoeconomic Analysis
A simple vapor-compression refrigeration system becomes ineffective and inefficient as it consumes a huge energy supply when operating between large temperature differences. Moreov...

Back to Top