RP HPLC Method Development for Simultaneous Estimation of Etoricoxib and Thiocolchicoside

View through CrossRef
A simple, specific and accurate reverse phase high performance liquid chromatography (RP-HPLC) method was developed and validated for simultaneous estimation of Etoricoxib and Thiocolchicoside in bulk and solid dosage form. Separation was achieved by Zorbax C-18 analytical column having dimension (250mm * 4.6 mm i.d 5.0 µm) using methanol and water (60:40) as mobile phase and flow rate was 0.7ml/min. The detection was carried out at 283 nm wavelength using UV detector. The total chromatographic sample time per analysis was about 14.0 minutes with thiocolchicoside eluted at retention time 3.523 min and etoricoxib eluted at retention time 9.627 min. The method was validated for accuracy, precision, specificity, rapid, reliable and reproducible. LOD and LOQ value for etoricoxib and thiocolchicoside were found to be 0.332, 0.996 ppm and 0976, 0.928 ppm respectively. Regression Equation for Etoricoxib was y = 0.006x + 0.149 and regression equation for thiocolchicoside was Y = 0.030x + 0.086. As the run time was increased the retention time was decreased, so the method is simple and economical and can be adopted by regular quality control in industries and also in research laboratories.
Title: RP HPLC Method Development for Simultaneous Estimation of Etoricoxib and Thiocolchicoside
Description:
A simple, specific and accurate reverse phase high performance liquid chromatography (RP-HPLC) method was developed and validated for simultaneous estimation of Etoricoxib and Thiocolchicoside in bulk and solid dosage form.
Separation was achieved by Zorbax C-18 analytical column having dimension (250mm * 4.
6 mm i.
d 5.
0 µm) using methanol and water (60:40) as mobile phase and flow rate was 0.
7ml/min.
The detection was carried out at 283 nm wavelength using UV detector.
The total chromatographic sample time per analysis was about 14.
0 minutes with thiocolchicoside eluted at retention time 3.
523 min and etoricoxib eluted at retention time 9.
627 min.
The method was validated for accuracy, precision, specificity, rapid, reliable and reproducible.
LOD and LOQ value for etoricoxib and thiocolchicoside were found to be 0.
332, 0.
996 ppm and 0976, 0.
928 ppm respectively.
Regression Equation for Etoricoxib was y = 0.
006x + 0.
149 and regression equation for thiocolchicoside was Y = 0.
030x + 0.
086.
As the run time was increased the retention time was decreased, so the method is simple and economical and can be adopted by regular quality control in industries and also in research laboratories.

Related Results

Potential role of Thiocolchicoside in anxiety disorder: A pre-clinical study
Potential role of Thiocolchicoside in anxiety disorder: A pre-clinical study
Abstract Aim :The aim of the current study is to evaluate anti-anxiety and potentiating effect of Thiocolchicoside in ani...
Analgesic Efficacy of Etoricoxib following Third Molar Surgery: A Meta-analysis
Analgesic Efficacy of Etoricoxib following Third Molar Surgery: A Meta-analysis
Background. The purpose of this meta-analysis was to assess the clinical efficacy of etoricoxib in comparison with traditional NSAIDs for postoperative pain after third molar surge...
Determination of Elemental Impurities in Etoricoxib a Non-steroidal Anti-inflammatory Drug by using ICP-MS
Determination of Elemental Impurities in Etoricoxib a Non-steroidal Anti-inflammatory Drug by using ICP-MS
Etoricoxib and its genotoxic impurities were identified using a variety of analytical techniques (UV, HPLC, HPTLC etc.) in accordance with previously published studies. The ICP-MS ...
NEW ANTIRHEUMATIC SUBSTANCE BASED ON PHENOLIC GLYCOSIDE STRUCTURE METHYL (4-О-Β-GLUCOPYRANOSYLOXY)-BENZOIC ACID
NEW ANTIRHEUMATIC SUBSTANCE BASED ON PHENOLIC GLYCOSIDE STRUCTURE METHYL (4-О-Β-GLUCOPYRANOSYLOXY)-BENZOIC ACID
Rheumatoid arthritis (RA) is a chronic inflammatory multifactorial disorder affecting approximately 1% of population, with over 3000000 new cases annually. The principal pharmacolo...
Comparative Evaluation of Efficacy of Therapeutic Ultrasound and Phonophoresis in Myofascial Pain Dysfunction Syndrome
Comparative Evaluation of Efficacy of Therapeutic Ultrasound and Phonophoresis in Myofascial Pain Dysfunction Syndrome
Introduction: Myofascial pain dysfunction syndrome (MPDS) is a common presenting condition in the dental office. No specific therapy has proven its superiority over the...
„Sambucus nigra“ and „Sambucus racemosa“ fruit: a schematic review on chemical characterization
„Sambucus nigra“ and „Sambucus racemosa“ fruit: a schematic review on chemical characterization
Elderberry is a plant which parts are used for healing purposes. It is rich in polyphenolic compounds (anthocyanins, flavonols, phenolic acids, proanthocyanidins). Black elderberry...

Back to Top