Attenuation-based ultra-low-dose lung computed tomography at 0.1 mSv to 0.3 mSv effective dose in children
View through CrossRef
Background
Radiation dose reduction is essential in paediatric lung computed tomography (CT). Advances in energy-integrating detector CT and deep-learning reconstruction may enable ultra-low-dose imaging comparable to photon-counting CT.
Objective
To evaluate the radiation dose and performance of an ultra-low-dose lung CT protocol using a wide-detector energy-integrating CT system in paediatric patients, focusing on effective radiation dose and diagnostic image quality.
Materials and methods
A total of 277 low-dose lung CT scans from 106 paediatric patients (age range, 113 days to 17.85 years) were retrospectively analysed. All scans were acquired in axial mode using a 256-slice-multidetector CT scanner with deep learning image reconstruction and attenuation-based Auto Prescription. Radiation dose parameters, including volume CT dose index, dose-length product, size-specific dose estimate, and effective dose, were calculated. Signal-to-noise ratio and contrast-to-noise ratio were assessed in standardised anatomical regions. Patients were stratified by age, and statistical analysis was conducted to evaluate dose trends and image quality metrics.
Results
There were significant differences between all age groups for all dose parameters (Kruskal–Wallis test,
P
<0.05). The median effective dose increased with age, ranging from 0.12 mSv (interquartile range (IQR) 0.09–0.14 mSv) in the 0–5-year group to 0.23 mSv (IQR 0.21–0.25 mSv) in adolescents aged 15 years to <18 years. Contrast-to-noise ratio and signal-to-noise ratio exhibited age-dependent variation with a small increase in older age groups. One-sided non-inferiority testing demonstrated that the signal-to-noise ratio and contrast-to-noise ratio in the youngest age group (0–5 years) were not significantly inferior to those in the ≥15-year group (
P
<0.05). All examinations were deemed diagnostically sufficient by board-certified paediatric radiologists. Non-disruptive artefacts such as cardiac motion and step artefacts occurred frequently but did not impair interpretation.
Conclusions
Ultra-low-dose lung CT using wide-detector energy-integrating CT with deep-learning image reconstruction allows for routine diagnostic imaging in children at radiation doses ranging from 0.12 mSv to 0.23 mSv, comparable to those reported for newer photon-counting CT systems. This approach provides a robust, clinically viable strategy for minimizing radiation exposure while maintaining diagnostic image quality.
Graphical abstract
Springer Science and Business Media LLC
Title: Attenuation-based ultra-low-dose lung computed tomography at 0.1 mSv to 0.3 mSv effective dose in children
Description:
Background
Radiation dose reduction is essential in paediatric lung computed tomography (CT).
Advances in energy-integrating detector CT and deep-learning reconstruction may enable ultra-low-dose imaging comparable to photon-counting CT.
Objective
To evaluate the radiation dose and performance of an ultra-low-dose lung CT protocol using a wide-detector energy-integrating CT system in paediatric patients, focusing on effective radiation dose and diagnostic image quality.
Materials and methods
A total of 277 low-dose lung CT scans from 106 paediatric patients (age range, 113 days to 17.
85 years) were retrospectively analysed.
All scans were acquired in axial mode using a 256-slice-multidetector CT scanner with deep learning image reconstruction and attenuation-based Auto Prescription.
Radiation dose parameters, including volume CT dose index, dose-length product, size-specific dose estimate, and effective dose, were calculated.
Signal-to-noise ratio and contrast-to-noise ratio were assessed in standardised anatomical regions.
Patients were stratified by age, and statistical analysis was conducted to evaluate dose trends and image quality metrics.
Results
There were significant differences between all age groups for all dose parameters (Kruskal–Wallis test,
P
<0.
05).
The median effective dose increased with age, ranging from 0.
12 mSv (interquartile range (IQR) 0.
09–0.
14 mSv) in the 0–5-year group to 0.
23 mSv (IQR 0.
21–0.
25 mSv) in adolescents aged 15 years to <18 years.
Contrast-to-noise ratio and signal-to-noise ratio exhibited age-dependent variation with a small increase in older age groups.
One-sided non-inferiority testing demonstrated that the signal-to-noise ratio and contrast-to-noise ratio in the youngest age group (0–5 years) were not significantly inferior to those in the ≥15-year group (
P
<0.
05).
All examinations were deemed diagnostically sufficient by board-certified paediatric radiologists.
Non-disruptive artefacts such as cardiac motion and step artefacts occurred frequently but did not impair interpretation.
Conclusions
Ultra-low-dose lung CT using wide-detector energy-integrating CT with deep-learning image reconstruction allows for routine diagnostic imaging in children at radiation doses ranging from 0.
12 mSv to 0.
23 mSv, comparable to those reported for newer photon-counting CT systems.
This approach provides a robust, clinically viable strategy for minimizing radiation exposure while maintaining diagnostic image quality.
Graphical abstract.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Analysis of the radiological dose and hazards assessment around swampy agricultural soil in Keffi, Nasarawa State, Nigeria
Analysis of the radiological dose and hazards assessment around swampy agricultural soil in Keffi, Nasarawa State, Nigeria
The present study analyzes radiological dose and hazard around the swampy agricultural soil in Keffi Local Government Area of Nasarawa State, using determined activity concentratio...
Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants
Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants
CONTEXT: Premature infant lung development may be affected by lung injuries during the first few weeks of life. Lung injuries have been associated with changes in lung mechanics. O...
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Radiomics is a new interdisciplinary field and a fusion product consisting by large data technology and medical image to aid diagnosis. Radiomics can gather information from differ...
Biological effective dose, cumulative radiation dose, risk of malignancy and mortality rate estimation in adult patients who have a history of cancer and exposed to recurrent computed tomography
Biological effective dose, cumulative radiation dose, risk of malignancy and mortality rate estimation in adult patients who have a history of cancer and exposed to recurrent computed tomography
Computed tomography is commonly used for the initial diagnosis of a tumour to provide information about the stage of cancer & to assess whether the disease is responding to tre...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Study on Physical Simulation Experimental Technology of Ultra-low Permeability Large-scale Outcrop Model
Study on Physical Simulation Experimental Technology of Ultra-low Permeability Large-scale Outcrop Model
Abstract
Ultra-low permeability reserves have accounted for a very large proportion of China's proven reserves and undeveloped reserves at present, so it is very ...
A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures
A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures
The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-wei...