Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures

View through CrossRef
The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk. We have therefore investigated patient effective doses from radiological examinations. Organ and effective doses were estimated for 94 patients who underwent computed tomography examinations and for 338 patients who had conventional radiography examinations. The OrgDose (version 2) program was used for the estimation of effective doses. The tube potential ranges: 57 kVp to 138 kVp depending on the examination and patient size. The entrance surface doses have a wide range even for the same examination: 0.44–10.31 mGy (abdomen) and 0.66–16.08 mGy (lumbar spine) and the corresponding effective dose ranges 0.025–0.77 mSv and 0.025–0.95 mSv respectively. Effective dose for adult abdomen-pelvic CT examinations ranges 5.4–19.8 mSv with a mean of 13.6 mSv and for pediatrics ranges 2.1–5.5 mSv with a mean of 2.7 mSv. The mean effective dose for adult chest and head CT examinations are 7.9 and 1.8 mSv respectively and for pediatrics are 1.7 and 1.1 mSv.
Title: A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures
Description:
The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays.
Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk.
We have therefore investigated patient effective doses from radiological examinations.
Organ and effective doses were estimated for 94 patients who underwent computed tomography examinations and for 338 patients who had conventional radiography examinations.
The OrgDose (version 2) program was used for the estimation of effective doses.
The tube potential ranges: 57 kVp to 138 kVp depending on the examination and patient size.
The entrance surface doses have a wide range even for the same examination: 0.
44–10.
31 mGy (abdomen) and 0.
66–16.
08 mGy (lumbar spine) and the corresponding effective dose ranges 0.
025–0.
77 mSv and 0.
025–0.
95 mSv respectively.
Effective dose for adult abdomen-pelvic CT examinations ranges 5.
4–19.
8 mSv with a mean of 13.
6 mSv and for pediatrics ranges 2.
1–5.
5 mSv with a mean of 2.
7 mSv.
The mean effective dose for adult chest and head CT examinations are 7.
9 and 1.
8 mSv respectively and for pediatrics are 1.
7 and 1.
1 mSv.

Related Results

AI and Incidental Findings
AI and Incidental Findings
Photo by Accuray on Unsplash INTRODUCTION Delayed and missed follow-up on incidental findings threatens patient health and is a major financial risk for healthcare systems. The hea...
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Abstract Background Diagnosis of neurogenic thoracic outlet syndrome (nTOS) is hindered by symptom overlap with cervical radiculopathy, carpal tunnel syndrome, or psychosomatic dis...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Organ donation following medical assistance in dying, Part II: a scoping review of existing processes and procedures
Organ donation following medical assistance in dying, Part II: a scoping review of existing processes and procedures
Objective: The objective of this review was to collate and summarize the current literature on what is known about organ donation following medical assistance in dying ...
Beyond Turf Wars: Redefining Boundaries and Building Consensus in Interventional Radiology
Beyond Turf Wars: Redefining Boundaries and Building Consensus in Interventional Radiology
Abstract Interventional radiology (IR) has evolved from diagnostic angiography to a core therapeutic specialty addressing acute ischemic stroke, peripheral arteri...
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Abstract Thoracic outlet syndrome (TOS) is a group of conditions caused by the compression of the neurovascular bundle within the thoracic outlet. It is classified into three main ...
Quality metrics currently used in academic radiology departments: results of the QUALMET survey
Quality metrics currently used in academic radiology departments: results of the QUALMET survey
Objective: We present the results of the 2015 quality metrics (QUALMET) survey, which was designed to assess the commonalities and variability of selected quality...

Back to Top