Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection

View through CrossRef
Abstract The present research endeavours to experimentally evaluate the ultimate and service shear strength of the cold‐formed steel (CFS) bolted clip‐angle connector in a CFS beam‐to‐column connection. A total of 58 laboratory tests were conducted on the 27 configurations of the clip‐angle by varying its thickness and aspect ratio (L/D). The governing failure modes observed in the two‐bolted clip‐angle are (i) Tearing and (ii) Shear local buckling. An improved ultimate shear capacity, which accounts for the pitch and slenderness ratios of the clip‐angle connector and the service shear capacity of the clip‐angle connector while accounting for clip‐angle configuration and material properties, was suggested for two bolted (2BS) beam‐to‐column connections. A 2BS connection with L/D ≤ 0.24 is recommended for high shear load design. A comparative study was conducted between the present bolted clip‐angle configuration and the existing screwed configuration. The design factors of Load and Resistance Factor Design (LRFD), Limit State Design (LSD), and Allowable Strength Design (ASD) methods were evaluated for the proposed shear equations by the reliability analysis.
Title: Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection
Description:
Abstract The present research endeavours to experimentally evaluate the ultimate and service shear strength of the cold‐formed steel (CFS) bolted clip‐angle connector in a CFS beam‐to‐column connection.
A total of 58 laboratory tests were conducted on the 27 configurations of the clip‐angle by varying its thickness and aspect ratio (L/D).
The governing failure modes observed in the two‐bolted clip‐angle are (i) Tearing and (ii) Shear local buckling.
An improved ultimate shear capacity, which accounts for the pitch and slenderness ratios of the clip‐angle connector and the service shear capacity of the clip‐angle connector while accounting for clip‐angle configuration and material properties, was suggested for two bolted (2BS) beam‐to‐column connections.
A 2BS connection with L/D ≤ 0.
24 is recommended for high shear load design.
A comparative study was conducted between the present bolted clip‐angle configuration and the existing screwed configuration.
The design factors of Load and Resistance Factor Design (LRFD), Limit State Design (LSD), and Allowable Strength Design (ASD) methods were evaluated for the proposed shear equations by the reliability analysis.

Related Results

Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
The worldwide poultry industry generates a large amount of wastes which, accordingly to the current law, are mostly discarded. These wastes include chicken feathers, keratin struct...
SHEAR BEHAVIOR OF NOVEL DEMOUNTABLE BOLTED SHEAR CONNECTOR FOR PREFABRICATED COMPOSITE BEAM
SHEAR BEHAVIOR OF NOVEL DEMOUNTABLE BOLTED SHEAR CONNECTOR FOR PREFABRICATED COMPOSITE BEAM
Bolted shear connectors offer alternatives to achieve steel-concrete composite action instead of conventional welded headed studs especially for prefabricated constructions and dem...
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
Abstract During the past year, a new mechanical pile connector has been introduced to the offshore construction industry. This connector has been the culmination ...
COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
Composite construction is well known to be effectively used in the construction of buildings and bridges using hot rolled steel (HRS) and headed studs connectors. The shear connect...
Influences of Various Parameters on Shear Stiffness of Bolted Joint Subjected to Shear Load
Influences of Various Parameters on Shear Stiffness of Bolted Joint Subjected to Shear Load
Abstract Multi-material structures have been required to reduce weight of vehicles in order to improve fuel efficiencies. To realize multi-material structures effectively, ...
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
In order to ensure desirable overall performance between interior panel and exterior panel for precast concrete sandwich panels, the shear performance of a new composite connector ...
Bolted Joint Simulation Techniques in Gas Turbine Components
Bolted Joint Simulation Techniques in Gas Turbine Components
Bolted joints are integral part of many industrial applications such as the most simple to the most complex and expensive machinery. They provide the primary means of connecting co...