COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
View through CrossRef
Composite construction is well known to be effectively used in the construction of buildings and bridges using hot rolled steel (HRS) and headed studs connectors. The shear connectors provides the enhancement as established in current design codes. In this paper, the shear connection mechanism was proposed using high strength bolted shear connector to provide composite action between concrete and the steel section. The conventional headed stud shear connector was eliminated since Cold-formed steel (CFS) was used and welding was not practically possible due to thinness nature of the CFS section. Therefore, in this study investigation was carried out on the strength capacity, ductility and the ultimate flexural capacity of the proposed high strength bolted shear connector and the composite beam specimens respectively. Four push-out and two full-scale composite beam specimens were fabricated using high strength M16 bolted shear connector of Grade 8.8 connected to the top flanges of the CFS I-section and tested to failure using push-out and four-point bending tests respectively. The results show that ultimate load and ultimate moment capacities of the proposed system were significantly improved by using the proposed connectors. The experimental results were compared with theoretical results based on the provision of Eurocode 4, and good agreement between the results was observed. In conclusion, compared results proved that the ultimate moment capacity of the proposed composite beams can be estimated efficiently by using the constitutive laws as prescribed by Eurocodes and British standards.
Penerbit UTM Press
Title: COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
Description:
Composite construction is well known to be effectively used in the construction of buildings and bridges using hot rolled steel (HRS) and headed studs connectors.
The shear connectors provides the enhancement as established in current design codes.
In this paper, the shear connection mechanism was proposed using high strength bolted shear connector to provide composite action between concrete and the steel section.
The conventional headed stud shear connector was eliminated since Cold-formed steel (CFS) was used and welding was not practically possible due to thinness nature of the CFS section.
Therefore, in this study investigation was carried out on the strength capacity, ductility and the ultimate flexural capacity of the proposed high strength bolted shear connector and the composite beam specimens respectively.
Four push-out and two full-scale composite beam specimens were fabricated using high strength M16 bolted shear connector of Grade 8.
8 connected to the top flanges of the CFS I-section and tested to failure using push-out and four-point bending tests respectively.
The results show that ultimate load and ultimate moment capacities of the proposed system were significantly improved by using the proposed connectors.
The experimental results were compared with theoretical results based on the provision of Eurocode 4, and good agreement between the results was observed.
In conclusion, compared results proved that the ultimate moment capacity of the proposed composite beams can be estimated efficiently by using the constitutive laws as prescribed by Eurocodes and British standards.
Related Results
Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
The worldwide poultry industry generates a large amount of wastes which, accordingly to the current law, are mostly discarded. These wastes include chicken feathers, keratin struct...
SHEAR BEHAVIOR OF NOVEL DEMOUNTABLE BOLTED SHEAR CONNECTOR FOR PREFABRICATED COMPOSITE BEAM
SHEAR BEHAVIOR OF NOVEL DEMOUNTABLE BOLTED SHEAR CONNECTOR FOR PREFABRICATED COMPOSITE BEAM
Bolted shear connectors offer alternatives to achieve steel-concrete composite action instead of conventional welded headed studs especially for prefabricated constructions and dem...
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
Abstract
During the past year, a new mechanical pile connector has been introduced to the offshore construction industry. This connector has been the culmination ...
Progressive damage of multiple bolt connections in thick composite plates
Progressive damage of multiple bolt connections in thick composite plates
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] Bonded connections are typically preferred for joining composite member. However, when supporting relatively ...
Theoretical and experimental study on cold-formed elements for steel framing in seismic areas
Theoretical and experimental study on cold-formed elements for steel framing in seismic areas
(English) This Thesis presents a theoretical and experimental study on cold-formed elements for seismic-resistant steel framing systems. The focus is on evaluating the feasibility ...
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
In order to ensure desirable overall performance between interior panel and exterior panel for precast concrete sandwich panels, the shear performance of a new composite connector ...
Influences of Various Parameters on Shear Stiffness of Bolted Joint Subjected to Shear Load
Influences of Various Parameters on Shear Stiffness of Bolted Joint Subjected to Shear Load
Abstract
Multi-material structures have been required to reduce weight of vehicles in order to improve fuel efficiencies. To realize multi-material structures effectively, ...
Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection
Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection
Abstract
The present research endeavours to experimentally evaluate the ultimate and service shear strength of the cold‐formed steel (CFS) bolted clip‐angle conne...