Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
View through CrossRef
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic performance and design method of an innovative CFS shear wall system with in-frame corrugated steel sheathing based on previous studies. Shear wall and bearing wall specimens with in-frame corrugated steel sheathing are tested under combined lateral and gravity loading. Simplified numerical models of whole archetype buildings are established. The seismic performance evaluation is performed using methodology recommended in FEMA P695 and the seismic performance factors are examined. The test results show that the shear strength of the innovative shear wall is much higher than currently code certified wood-based shear walls in AISI S400. Also, the shear strength of bearing walls is approximately one-third of the shear strength of shear walls, which proves that bearing walls also contribute significant shear resistance in a structure. The seismic performance evaluation results verified that the existing seismic performance factors (R = Cd = 6.5 and [Formula: see text] = 3.0) for CFS shear walls with flat steel sheathings can also be used for the innovative shear wall system. The innovative CFS shear wall system with in-frame corrugated steel sheathing could be employed for mid-rise buildings in areas that are prone to high seismic and wind loads.
SAGE Publications
Title: Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
Description:
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic performance and design method of an innovative CFS shear wall system with in-frame corrugated steel sheathing based on previous studies.
Shear wall and bearing wall specimens with in-frame corrugated steel sheathing are tested under combined lateral and gravity loading.
Simplified numerical models of whole archetype buildings are established.
The seismic performance evaluation is performed using methodology recommended in FEMA P695 and the seismic performance factors are examined.
The test results show that the shear strength of the innovative shear wall is much higher than currently code certified wood-based shear walls in AISI S400.
Also, the shear strength of bearing walls is approximately one-third of the shear strength of shear walls, which proves that bearing walls also contribute significant shear resistance in a structure.
The seismic performance evaluation results verified that the existing seismic performance factors (R = Cd = 6.
5 and [Formula: see text] = 3.
0) for CFS shear walls with flat steel sheathings can also be used for the innovative shear wall system.
The innovative CFS shear wall system with in-frame corrugated steel sheathing could be employed for mid-rise buildings in areas that are prone to high seismic and wind loads.
Related Results
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel
Incombustibility is one important advantage of the sheet steel sheathed shear wall over wood panel sheathed shear wall. Compared to shear wall sheathed with plywood and OSB panel, ...
Cyclic Behavior of New Steel Plate Shear Walls Reinforced with Trapezoidal Corrugated Plates
Cyclic Behavior of New Steel Plate Shear Walls Reinforced with Trapezoidal Corrugated Plates
Unstiffened steel plate shear walls have low buckling strength, which caused development diagonal tension field under lateral load. Corrugated plates have higher out-of-plane stiff...
The seismic analysis and performance of steel frame with additional low-yield-point steel dampers
The seismic analysis and performance of steel frame with additional low-yield-point steel dampers
This paper describes the seismic performance of a steel frame with additional LYP steel dampers. LYP steel dampers provides passive energy dissipation device in a structure, it als...
An analysis of seismic behavior of brick shear wall in cold-formed steel frame
An analysis of seismic behavior of brick shear wall in cold-formed steel frame
The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high executi...
SEISMIC EVALUATION OF ADVANCED CONNECTION SYSTEMS IN WOOD-FRAMED SHEAR WALLS FOR STRUCTURAL DESIGN
SEISMIC EVALUATION OF ADVANCED CONNECTION SYSTEMS IN WOOD-FRAMED SHEAR WALLS FOR STRUCTURAL DESIGN
Wood-framed shear walls are commonly used to construct low- to mid-rise buildings, particularly in seismic regions. However, as seismic demands increase, the need for more robust, ...
Design aspects of steel I-girders with corrugated steel webs
Design aspects of steel I-girders with corrugated steel webs
Corrugated web girders represent a new structural system emerged in the past two decades. The girder’s flanges provide the flexural strength of the girder with no contribution from...
Application of Framing Effects of Health Promotion Information in Hypertension Management