Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

An analysis of seismic behavior of brick shear wall in cold-formed steel frame

View through CrossRef
The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high execution speed, and ease of repair. In this article, for the first time, the effect of stud spacing and execution method on the seismic behavior of brick shear walls in a cold-formed steel frame (CFSF) was investigated. For this purpose, 6 shear walls, A1: shear wall was made of steel frame with the dimensions of 2400 × 600 mm; A2: shear wall was the same as A1 wall, with the difference that the brick is installed in two stages; B1 and B2: B1 and B2 shear walls were made of steel frames with dimensions of 2400 × 1200 mm; C1 and C2 Shear walls are similar to B1 and B2 walls, the difference is that in these walls, all the space inside the frame was filled with expanded polystyrene plates and mortar was applied outside the frame and on it were made using CFSF, cement sand mortar, wire mesh, expanded polystyrene, automatic screw, ceramic and clay brick. After processing in the laboratory, these walls were subjected to seismic loading. By calculating the over-strength factor and ductility reduction factor using experimental results, it was determined that building the wall in one step (A1 compared to A2) and increasing the distance between the studs (B1 and B2 compared to A1) would increase the shear strength, but this does not cause a significant change in the behavior factor. Also, using the two methods of Uang and Pauli to calculate the behavior factor leads to almost the same results.
Title: An analysis of seismic behavior of brick shear wall in cold-formed steel frame
Description:
The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high execution speed, and ease of repair.
In this article, for the first time, the effect of stud spacing and execution method on the seismic behavior of brick shear walls in a cold-formed steel frame (CFSF) was investigated.
For this purpose, 6 shear walls, A1: shear wall was made of steel frame with the dimensions of 2400 × 600 mm; A2: shear wall was the same as A1 wall, with the difference that the brick is installed in two stages; B1 and B2: B1 and B2 shear walls were made of steel frames with dimensions of 2400 × 1200 mm; C1 and C2 Shear walls are similar to B1 and B2 walls, the difference is that in these walls, all the space inside the frame was filled with expanded polystyrene plates and mortar was applied outside the frame and on it were made using CFSF, cement sand mortar, wire mesh, expanded polystyrene, automatic screw, ceramic and clay brick.
After processing in the laboratory, these walls were subjected to seismic loading.
By calculating the over-strength factor and ductility reduction factor using experimental results, it was determined that building the wall in one step (A1 compared to A2) and increasing the distance between the studs (B1 and B2 compared to A1) would increase the shear strength, but this does not cause a significant change in the behavior factor.
Also, using the two methods of Uang and Pauli to calculate the behavior factor leads to almost the same results.

Related Results

Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic perfor...
The seismic analysis and performance of steel frame with additional low-yield-point steel dampers
The seismic analysis and performance of steel frame with additional low-yield-point steel dampers
This paper describes the seismic performance of a steel frame with additional LYP steel dampers. LYP steel dampers provides passive energy dissipation device in a structure, it als...
Analisis Simpangan Pada Portal Terbuka dan Portal Tertutup Pada Bangunan Bertingkat Beton Bertulang
Analisis Simpangan Pada Portal Terbuka dan Portal Tertutup Pada Bangunan Bertingkat Beton Bertulang
In designing structures such as portals, planning generally does not take into account filler components such as bricks as structural components, only considered non-structural com...
Effect of middle stud on ultimate strength and behavior factor of brick masonry shear wall in cold formed steel frame
Effect of middle stud on ultimate strength and behavior factor of brick masonry shear wall in cold formed steel frame
AbstractLightweight steel framing is one of the modern construction technology systems. This system is mostly used for low to mid-rise buildings. The lightweight steel framing syst...
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel
Incombustibility is one important advantage of the sheet steel sheathed shear wall over wood panel sheathed shear wall. Compared to shear wall sheathed with plywood and OSB panel, ...
Seismic Assessment of Multistorey building of plan irregularity with varying A/L ratio (Re-entrants corners)
Seismic Assessment of Multistorey building of plan irregularity with varying A/L ratio (Re-entrants corners)
Abstract Buildings with re-entrant corners are used when maximum utilization is done over minimum available space. These re-entrant corners come under the plan irreg...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...

Back to Top