Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of middle stud on ultimate strength and behavior factor of brick masonry shear wall in cold formed steel frame

View through CrossRef
AbstractLightweight steel framing is one of the modern construction technology systems. This system is mostly used for low to mid-rise buildings. The lightweight steel framing system has many advantages, including lightness, ease of installation, high execution speed, and being more cost-efficient. Since the manufacturers of cold formed steel frames use bricks in an unprincipled way to cover these structures and because of less laboratory research in this regard, in the present research to principled use of this structure, the effect of the middle stud was evaluated on seismic behavior of brick shear wall in cold formed steel frame with brick face. For this purpose, four cold formed steel frames were made in two different configurations (without middle stud and with middle stud) using cement sand mortar, wire mesh, and brick shear walls. Based on the results, the middle stud would cause weakness in the permissible deformation of the brick walls, and in shear walls without middle stud, deformations occur along with the acquisition of resistance to larger deformations. Accordingly, the presence of the middle stud increases the average shear strength by 30%, and this increase in resistance causes a decrease in the behavior factor and ductility of the walls, which practically indicates the seismic behavior of the frames with the middle stud.
Title: Effect of middle stud on ultimate strength and behavior factor of brick masonry shear wall in cold formed steel frame
Description:
AbstractLightweight steel framing is one of the modern construction technology systems.
This system is mostly used for low to mid-rise buildings.
The lightweight steel framing system has many advantages, including lightness, ease of installation, high execution speed, and being more cost-efficient.
Since the manufacturers of cold formed steel frames use bricks in an unprincipled way to cover these structures and because of less laboratory research in this regard, in the present research to principled use of this structure, the effect of the middle stud was evaluated on seismic behavior of brick shear wall in cold formed steel frame with brick face.
For this purpose, four cold formed steel frames were made in two different configurations (without middle stud and with middle stud) using cement sand mortar, wire mesh, and brick shear walls.
Based on the results, the middle stud would cause weakness in the permissible deformation of the brick walls, and in shear walls without middle stud, deformations occur along with the acquisition of resistance to larger deformations.
Accordingly, the presence of the middle stud increases the average shear strength by 30%, and this increase in resistance causes a decrease in the behavior factor and ductility of the walls, which practically indicates the seismic behavior of the frames with the middle stud.

Related Results

Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Behavior of headed shear studs in stub–girder stub assemblages
Behavior of headed shear studs in stub–girder stub assemblages
The paper summarizes the results of push-off tests conducted on 42 end stub assemblages. Written for conventional composite construction, the current Canadian Standards Association...
STUDI KARAKTERISTIK BATA MERAH LOKAL BALI SEBAGAI DINDING
STUDI KARAKTERISTIK BATA MERAH LOKAL BALI SEBAGAI DINDING
Abstract : This study was conducted to determine the characteristics of brick red walls. Red brick taken from a local brick manufacturer Gianyar, Tabanan and  Negara refer to SNI 1...
Use of Naltrexone for Patients With Stimulant Use Disorder in Malaysia: Protocol for a Retrospective Cohort Study
Use of Naltrexone for Patients With Stimulant Use Disorder in Malaysia: Protocol for a Retrospective Cohort Study
Background Naltrexone is an opioid receptor antagonist. Naltrexone is used to block the euphoric and sedative effects of drugs such as heroin, codeine, and morp...
An analysis of seismic behavior of brick shear wall in cold-formed steel frame
An analysis of seismic behavior of brick shear wall in cold-formed steel frame
The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high executi...
Stress and strain studies of historical masonry
Stress and strain studies of historical masonry
Introduction . Brick masonry of historical buildings has a number of features compared to masonry made of contemporary materials. This applies to both strength ...
Evaluation of Existing Moisture Content in Brick for Hygrothermal Models in the Rehabilitation of Mass Masonry Walls
Evaluation of Existing Moisture Content in Brick for Hygrothermal Models in the Rehabilitation of Mass Masonry Walls
A research study was undertaken to evaluate an in situ test method for determining the existing moisture content of brick masonry for use in hygrothermal models. Currently, ASTM E3...

Back to Top