Javascript must be enabled to continue!
Experimental investigation of the service shear strength of the welded clip‐angle connector in a CFS beam‐to‐column connection
View through CrossRef
Abstract
The present research endeavours to experimentally evaluate the service shear strength of the cold‐formed steel (CFS) welded clip‐angle connector in a CFS beam‐to‐column connection. A total of 30 laboratory tests were conducted on the 27 configurations of the clip‐angle by varying its thickness, width, and depth. The governing design failure modes observed in the welded clip‐angle are (i) Local buckling and (ii) Distortional buckling. The existing traditional elastic design approach for the service limit state design of CFS connector was found to be highly conservative for most of the welded clip‐angle specimens. Hence a new design approach is developed for the welded clip‐angle configuration and the corresponding design shear equation is suggested. A comparative study was conducted between the present welded clip‐angle configuration and existing screwed configuration. The design recommendations were suggested for the efficient design of the connection for the welded clip‐angle configuration. The relevant design factors for the suggested shear equations of welded clip‐angle were evaluated from the reliability analysis.
Title: Experimental investigation of the service shear strength of the welded clip‐angle connector in a CFS beam‐to‐column connection
Description:
Abstract
The present research endeavours to experimentally evaluate the service shear strength of the cold‐formed steel (CFS) welded clip‐angle connector in a CFS beam‐to‐column connection.
A total of 30 laboratory tests were conducted on the 27 configurations of the clip‐angle by varying its thickness, width, and depth.
The governing design failure modes observed in the welded clip‐angle are (i) Local buckling and (ii) Distortional buckling.
The existing traditional elastic design approach for the service limit state design of CFS connector was found to be highly conservative for most of the welded clip‐angle specimens.
Hence a new design approach is developed for the welded clip‐angle configuration and the corresponding design shear equation is suggested.
A comparative study was conducted between the present welded clip‐angle configuration and existing screwed configuration.
The design recommendations were suggested for the efficient design of the connection for the welded clip‐angle configuration.
The relevant design factors for the suggested shear equations of welded clip‐angle were evaluated from the reliability analysis.
Related Results
Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
Avaluació d'alternatives industrials per a l'obtenció de nous materials que valoritzen residus queratínics
The worldwide poultry industry generates a large amount of wastes which, accordingly to the current law, are mostly discarded. These wastes include chicken feathers, keratin struct...
Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection
Experimental Investigation of the Ultimate and Service Shear Strength of the Bolted Clip‐Angle Connector in a CFS Beam‐to‐Column Connection
Abstract
The present research endeavours to experimentally evaluate the ultimate and service shear strength of the cold‐formed steel (CFS) bolted clip‐angle conne...
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
Abstract
During the past year, a new mechanical pile connector has been introduced to the offshore construction industry. This connector has been the culmination ...
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE OF COMPOSITE CONNECTOR FOR PRECAST CONCRETE SANDWICH PANELS
In order to ensure desirable overall performance between interior panel and exterior panel for precast concrete sandwich panels, the shear performance of a new composite connector ...
Features of the welded seam material crystalliza-tion in Ti-TiB alloy under electron-beam welding conditions
Features of the welded seam material crystalliza-tion in Ti-TiB alloy under electron-beam welding conditions
Natural metal composite materials represent a promising class of modern structural materials that need to be welded. Such materials can be welded by fusion, as has been established...
Numerical analysis of the beam-column connection stiffness in precast concrete with welded steel angle
Numerical analysis of the beam-column connection stiffness in precast concrete with welded steel angle
The use of precast elements in civil construction has the main advantag of expediting the structures construction process, as well as increased technological control of the materi...
Predictors for Developing Severe Myalgic Encephalomyelitis/Chronic Fatigue Syndrome following Infectious Mononucleosis
Predictors for Developing Severe Myalgic Encephalomyelitis/Chronic Fatigue Syndrome following Infectious Mononucleosis
Background: About 10% of individuals who contract infectious mononucleosis (IM) have symptoms 6 months later that meet criteria for myalgic encephalomyelitis/chronic fatigue syndro...
COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
COMPOSITE CONSTRUCTION OF COLD-FORMED STEEL (CFS) SECTION WITH HIGH STRENGTH BOLTED SHEAR CONNECTOR
Composite construction is well known to be effectively used in the construction of buildings and bridges using hot rolled steel (HRS) and headed studs connectors. The shear connect...