Assessment and Correlation of Corneal Endothelial Cell Changes in Different Stages of Keratoconus in Non–contact Lens Wearers
View through CrossRef
Supplemental digital content is available in the text.
SIGNIFICANCE
The endothelial changes in keratoconus are of interest because these can affect the surgical plan in management. Previously, many studies have evaluated the endothelium in eyes with keratoconus, but there is no common consensus on change in endothelial cell density (ECD) with studies showing variable results.
PURPOSE
This study aimed to compare and correlate endothelial cell parameters in different stages of keratoconus using specular microscope.
METHODS
This cross‐sectional, cohort, comparative study included 162 eyes of 96 patients with keratoconus in one or both eyes. Corneal endothelial cell parameters were assessed with SP‐1P specular microscope (Topcon Co., Tokyo, Japan). Corneal topography and thickness data were obtained from Sirius tomographer (Costruzione Strumenti Oftalmici, Florence, Italy). Eyes were divided into keratoconus stage 0 to 4 according to ABCD classification. Comparison and correlation of endothelial cell parameters in different stages were done.
RESULTS
There were 21.6% eyes (35) in stage 0, 29.6% eyes (48) in stage 1, 29.0% eyes (47) in stage 2, and 19.8% eyes (32) in stage 3 of keratoconus. Measurement was not possible in stage 4 keratoconus. Among the stages 0, 1, 2, and 3, the ECD was 3024, 3051, 3025, and 3043 cells/mm
2
; coefficient of variation was 27.2, 27.6, 26.8, and 27.4; and frequency of hexagon cells was 61.5, 63.7, 63.3, and 62.3, respectively (
P
>. 05). The number of analyzed cells was 232, 209, 185, and 169 in stages 0, 1, 2, and 3, respectively (
P
<. 001). No significant difference was found in minimum, maximum, and average cell area between the stages (
P
>. 05). A weak Spearman rank correlation of ECD, coefficient of variation, and frequency of hexagon cells was found between eyes with keratoconus stages 0 and 1 and stages 2 and 3 (
r
= −0.05,
P
=. 65;
r
= −0.11,
P
=. 37;
r
= 0.05,
P
=. 67, respectively). No significant correlation was found in the number of cells analyzed and minimum, maximum, and average cell area between the stages (
P
>. 05).
CONCLUSIONS
Endothelial cell parameters do not show any significant changes and correlation up to stage 3 of keratoconus in non–contact lens wearers.
Title: Assessment and Correlation of Corneal Endothelial Cell Changes in Different Stages of Keratoconus in Non–contact Lens Wearers
Description:
Supplemental digital content is available in the text.
SIGNIFICANCE
The endothelial changes in keratoconus are of interest because these can affect the surgical plan in management.
Previously, many studies have evaluated the endothelium in eyes with keratoconus, but there is no common consensus on change in endothelial cell density (ECD) with studies showing variable results.
PURPOSE
This study aimed to compare and correlate endothelial cell parameters in different stages of keratoconus using specular microscope.
METHODS
This cross‐sectional, cohort, comparative study included 162 eyes of 96 patients with keratoconus in one or both eyes.
Corneal endothelial cell parameters were assessed with SP‐1P specular microscope (Topcon Co.
, Tokyo, Japan).
Corneal topography and thickness data were obtained from Sirius tomographer (Costruzione Strumenti Oftalmici, Florence, Italy).
Eyes were divided into keratoconus stage 0 to 4 according to ABCD classification.
Comparison and correlation of endothelial cell parameters in different stages were done.
RESULTS
There were 21.
6% eyes (35) in stage 0, 29.
6% eyes (48) in stage 1, 29.
0% eyes (47) in stage 2, and 19.
8% eyes (32) in stage 3 of keratoconus.
Measurement was not possible in stage 4 keratoconus.
Among the stages 0, 1, 2, and 3, the ECD was 3024, 3051, 3025, and 3043 cells/mm
2
; coefficient of variation was 27.
2, 27.
6, 26.
8, and 27.
4; and frequency of hexagon cells was 61.
5, 63.
7, 63.
3, and 62.
3, respectively (
P
>.
05).
The number of analyzed cells was 232, 209, 185, and 169 in stages 0, 1, 2, and 3, respectively (
P
<.
001).
No significant difference was found in minimum, maximum, and average cell area between the stages (
P
>.
05).
A weak Spearman rank correlation of ECD, coefficient of variation, and frequency of hexagon cells was found between eyes with keratoconus stages 0 and 1 and stages 2 and 3 (
r
= −0.
05,
P
=.
65;
r
= −0.
11,
P
=.
37;
r
= 0.
05,
P
=.
67, respectively).
No significant correlation was found in the number of cells analyzed and minimum, maximum, and average cell area between the stages (
P
>.
05).
CONCLUSIONS
Endothelial cell parameters do not show any significant changes and correlation up to stage 3 of keratoconus in non–contact lens wearers.
Related Results
Corneal densitometry analysis in patients diagnosed with keratoconus
Corneal densitometry analysis in patients diagnosed with keratoconus
AbstractPurposeThe purpose of this study is to carry out a comparative study of corneal densitometry (COD) using Pentacam HR in two groups of patients. A control group of normal ey...
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Abstract
Background
To compare the corneal deformation response between patients with keratoconus and healthy subjects and to identify potential characteristics associated...
Topographic Keratoconus Incidence in Greece Diagnosed in Routine Consecutive Cataract Procedures: A Consecutive Case Series of 1250 Cases over 5 Years
Topographic Keratoconus Incidence in Greece Diagnosed in Routine Consecutive Cataract Procedures: A Consecutive Case Series of 1250 Cases over 5 Years
Background: Scheimpflug tomography has for many years been an integral part of our pre-operative assessment in cataract extraction. We retrospectively reviewed the incidence of top...
Vision‐Specific Quality of Life and Modes of Refractive Error Correction
Vision‐Specific Quality of Life and Modes of Refractive Error Correction
ABSTRACT:
Purpose
Many studies currently use surveys to assess patients’ reports of vision‐specific quality of life to de...
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
ABSTRACT
Purpose.
The purpose of this study is to investigate the comparative clinical performance of two hyper Dk contac...
Assessment of corneal reflex and vision-related functions among contact lens wearers: a cross-sectional study
Assessment of corneal reflex and vision-related functions among contact lens wearers: a cross-sectional study
Abstract
Purpose
To evaluate the effects of soft, hard, and scleral contact lenses (CLs) on corneal reflex sensitivity and visi...
Keratoconus Screening in Primary Eye Care – A General Overview
Keratoconus Screening in Primary Eye Care – A General Overview
Keratoconus early detection (screening) and diagnosis requires an in-deep corneal analysis with different techniques; slip lamp assessment, corneal topography and corneal tomograph...
Keratoconus: Current perspectives
Keratoconus: Current perspectives
Keratoconus is a corneal thinning disorder in which the inferior paracentral cornea thins and protrudes forwards. The onset is usually during the second decade. Blurred vision and ...