Javascript must be enabled to continue!
Outcomes in Patients Implanted With a Watchman Device in Relation to Choice of Anticoagulation and Indication for Implant
View through CrossRef
Background Patients with atrial fibrillation are increasingly prescribed
a direct oral anticoagulant (DOAC) over warfarin and seek to avoid
anticoagulation even without a history of major bleeding. This study
explores the outcomes of patients implanted with a Watchman device in
relation to anticoagulation choice (warfarin versus DOAC) in the
post-procedure period and a history of bleeding. Methods Patients
implanted with a Watchman device at a single center were retrospectively
analyzed. Characteristics including anticoagulation in the first 45 days
and history of major bleed were assessed and efficacy (thromboembolism)
and safety (bleeding) outcomes compared by Kaplan-Meier analysis.
Results 209 patients were implanted (57% male, age 74.6 7.8 years)
and followed for 23.5 ± 7.1 months. In the first half of patients, 98%
were prescribed warfarin, which dropped to 51% in the second half
(p<0.0001). A history of major bleed was present in 80.8% of
the first half of patients and decreased to 60% in the second half
(p=0.001). There were 16 safety and 4 efficacy events. There was no
difference in safety outcomes according to history of major bleeding or
anticoagulant choice in the first 45 days. There was no difference in
efficacy outcomes over the duration of follow up according to
anticoagulation choice in the first 45 days. Conclusions Patients
implanted with a Watchman device were increasingly over time prescribed
a DOAC and implanted without a history of major bleeding. Bleeding and
thromboembolic events were infrequent and related neither to choice of
anticoagulant nor to prior major bleeding.
Title: Outcomes in Patients Implanted With a Watchman Device in Relation to Choice of Anticoagulation and Indication for Implant
Description:
Background Patients with atrial fibrillation are increasingly prescribed
a direct oral anticoagulant (DOAC) over warfarin and seek to avoid
anticoagulation even without a history of major bleeding.
This study
explores the outcomes of patients implanted with a Watchman device in
relation to anticoagulation choice (warfarin versus DOAC) in the
post-procedure period and a history of bleeding.
Methods Patients
implanted with a Watchman device at a single center were retrospectively
analyzed.
Characteristics including anticoagulation in the first 45 days
and history of major bleed were assessed and efficacy (thromboembolism)
and safety (bleeding) outcomes compared by Kaplan-Meier analysis.
Results 209 patients were implanted (57% male, age 74.
6 7.
8 years)
and followed for 23.
5 ± 7.
1 months.
In the first half of patients, 98%
were prescribed warfarin, which dropped to 51% in the second half
(p<0.
0001).
A history of major bleed was present in 80.
8% of
the first half of patients and decreased to 60% in the second half
(p=0.
001).
There were 16 safety and 4 efficacy events.
There was no
difference in safety outcomes according to history of major bleeding or
anticoagulant choice in the first 45 days.
There was no difference in
efficacy outcomes over the duration of follow up according to
anticoagulation choice in the first 45 days.
Conclusions Patients
implanted with a Watchman device were increasingly over time prescribed
a DOAC and implanted without a history of major bleeding.
Bleeding and
thromboembolic events were infrequent and related neither to choice of
anticoagulant nor to prior major bleeding.
Related Results
Extraction of Watchman device using a double transeptal approach
Extraction of Watchman device using a double transeptal approach
Abstract
Background
Left atrial appendage occlusion is a treatment for patients with atrial fibrillation who have a high risk of...
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
Therapeutic versus Prophylactic Anticoagulation for Patients Admitted to Hospital with COVID-19 and Elevated D-dimer Concentration (ACTION): An Open-Label, Multicentre, Randomised, Controlled Trial
Therapeutic versus Prophylactic Anticoagulation for Patients Admitted to Hospital with COVID-19 and Elevated D-dimer Concentration (ACTION): An Open-Label, Multicentre, Randomised, Controlled Trial
Background. COVID-19 is associated with a prothrombotic state leading to adverse clinical outcomes. Whether therapeutic anticoagulation improves outcomes in patients hospitalised w...
One year outcome and analysis of peri-device leak of left atrial appendage occlusion devices
One year outcome and analysis of peri-device leak of left atrial appendage occlusion devices
Abstract
Background
The prevalence of peri-device leak (PDL) of left atrial appendage occlusion (LAAO) devices has been previous...
Techniques to Remove Press-Fit Osseointegration Implants
Techniques to Remove Press-Fit Osseointegration Implants
Background:
Transcutaneous osseointegration for amputees (TOFA) has proven to consistently, significantly improve the quality of life and...
Does High-Dose Thromboprophylaxis Improve Outcomes in COVID-19 Patients? A Meta-analysis of Comparative Studies
Does High-Dose Thromboprophylaxis Improve Outcomes in COVID-19 Patients? A Meta-analysis of Comparative Studies
Abstract
Background Thromboembolism remains a detrimental complication of novel coronavirus disease (COVID-19) despite the use of prophylactic doses of anticoagulation
...
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract
Background
Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...

