The Best Dentistry Professional Visual Acuity Measured under Simulated Clinical Conditions Provides Keplerian Magnification Loupe: A Cross-Sectional Study
View through CrossRef
Visual acuity plays an important role in dentists’ vision in their daily clinical routine. This study aimed to determine dental students’ visual acuity without optical aids and when using magnification devices in simulated clinical conditions. The participants were forty-six students at the School of Dental Medicine with a visual acuity of 1.0 in decimal values or 100% in percentage. The central visual acuity was tested using a miniature Snellen eye chart placed in the molar cavity of a dental phantom, in simulated clinical conditions under five different settings (natural visual acuity, by applying head magnifying glasses x1,5 and binocular magnifying devices using Galileo’s x2,5/350 mm, Keplerx3,3/450 mm and Keplerx4,5/350 mm optical system). The Wilcoxon Signed Rank test shows that the distribution of measurements of the visual acuity undertaken by the application of magnifying devices (VNL, VGA2,5, VKP3,3, VKP4,5) contained higher values of visual acuity than those received by the use of natural vision (VSC) (p < 0.001 for the comparison to the VNL, VGA2,5, VKP3,3 and VKP4,5 groups). The highest and statistically most significant increase in visual acuity is achieved using the Keplerian telescope x4.5/350 mm. The application of magnifying devices provided dentistry professionals with better visual acuity, improving detail detection in an oral cavity during dental procedures by magnifying the oral structure. The use of magnification devices means much more precise work, decreases the operating time, improves posture and reduces muscle pain in the shoulder during dental treatment.
Title: The Best Dentistry Professional Visual Acuity Measured under Simulated Clinical Conditions Provides Keplerian Magnification Loupe: A Cross-Sectional Study
Description:
Visual acuity plays an important role in dentists’ vision in their daily clinical routine.
This study aimed to determine dental students’ visual acuity without optical aids and when using magnification devices in simulated clinical conditions.
The participants were forty-six students at the School of Dental Medicine with a visual acuity of 1.
0 in decimal values or 100% in percentage.
The central visual acuity was tested using a miniature Snellen eye chart placed in the molar cavity of a dental phantom, in simulated clinical conditions under five different settings (natural visual acuity, by applying head magnifying glasses x1,5 and binocular magnifying devices using Galileo’s x2,5/350 mm, Keplerx3,3/450 mm and Keplerx4,5/350 mm optical system).
The Wilcoxon Signed Rank test shows that the distribution of measurements of the visual acuity undertaken by the application of magnifying devices (VNL, VGA2,5, VKP3,3, VKP4,5) contained higher values of visual acuity than those received by the use of natural vision (VSC) (p < 0.
001 for the comparison to the VNL, VGA2,5, VKP3,3 and VKP4,5 groups).
The highest and statistically most significant increase in visual acuity is achieved using the Keplerian telescope x4.
5/350 mm.
The application of magnifying devices provided dentistry professionals with better visual acuity, improving detail detection in an oral cavity during dental procedures by magnifying the oral structure.
The use of magnification devices means much more precise work, decreases the operating time, improves posture and reduces muscle pain in the shoulder during dental treatment.
Related Results
Clinical results according to cause of endophthalmitis
Clinical results according to cause of endophthalmitis
AbstractPurposeTo analysis clinical features according to the cause of endophthalmitis and evaluate the factors associated with final visual acuity.MethodsWe retrospectively review...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Visual acuity in the cathemeral strepsirrhine Eulemur macaco flavifrons
Visual acuity in the cathemeral strepsirrhine Eulemur macaco flavifrons
AbstractStudies of visual acuity in primates have shown that diurnal haplorhines have higher acuity (30–75 cycles per degree (c/deg)) than most other mammals. However, relatively l...
Effectiveness of toric soft contact lenses for vision correction in patients with different degrees of astigmatism: a real-world study
Effectiveness of toric soft contact lenses for vision correction in patients with different degrees of astigmatism: a real-world study
AIM: To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses (TSC).
METHODS: It was a real-world study with prospective and...
Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
AbstractPurposeThe purpose of this study is to develop a straightforward mathematical concept for determination of object to image magnification in both phakic and pseudophakic eye...
Utilizing Lactation Acuity to Improve Lactation Services in a U.S. Hospital
Utilizing Lactation Acuity to Improve Lactation Services in a U.S. Hospital
National staffing guidelines for hospital lactation services do not account for the lactation acuity of breastfeeding patients. Higher acuity breastfeeding couplets require a highe...
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Abstract
Purpose To study the changes and correlation of visual acuity, pupil size, kappa angle and Alpha angle after phacoemulsification combined with multifocal intraocul...
Surgical magnification in dental hygiene practice
Surgical magnification in dental hygiene practice
Abstract: The potential for improving the occupational health of dental clinicians has expanded as increasingly sophisticated equipment enters the marketplace, yet there has been ...