Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Corneal Biomechanics in Normal and Subclinical Keratoconus Eyes

View through CrossRef
Abstract Background The diagnosis of keratoconus, as the most prevalent corneal ectatic disorder, at the subclinical stage gained great attention due to the increased acceptance of refractive surgeries. This study aimed to assess the pattern of the corneal biomechanical properties derived from Corneal Visualization Scheimpflug Technology (Corvis ST) and evaluate the diagnostic value of these parameters in distinguishing subclinical keratoconus (SKC) from normal eyes. Methods This prospective study was conducted on 73 SKC and 69 normal eyes. Subclinical keratoconus eyes were defined as corneas with no clinical evidence of keratoconus and suspicious tomographic and tomographic features. Following a complete ophthalmic examination, topographic and tomographic corneal assessment via Pentacam HR, and corneal biomechanical evaluation utilizing Corvis ST were done. Results Subclinical keratoconus eyes presented significantly higher Deformation Amplitude (DA) ratio, Tomographic Biomechanical Index (TBI), and Corvis Biomechanical Index (CBI) rates than the control group. Conversely, Ambrósio Relational Thickness to the Horizontal profile (ARTh), and Stiffness Parameter at the first Applanation (SPA1) showed significantly lower rates in SKC eyes. In diagnosing SKC from normal eyes, TBI (AUC: 0.858, Cut-off value: > 0.33, Youden index: 0.55), ARTh (AUC: 0.813, Cut-off value: ≤ 488.1, Youden index: 0.58), and CBI (AUC: 0.804, Cut-off value: > 0.47, Youden index: 0.49) appeared as good indicators. Conclusions Integrated Corvis ST parameters could be valuable in distinguishing SKC eyes from normal ones.
Title: Corneal Biomechanics in Normal and Subclinical Keratoconus Eyes
Description:
Abstract Background The diagnosis of keratoconus, as the most prevalent corneal ectatic disorder, at the subclinical stage gained great attention due to the increased acceptance of refractive surgeries.
This study aimed to assess the pattern of the corneal biomechanical properties derived from Corneal Visualization Scheimpflug Technology (Corvis ST) and evaluate the diagnostic value of these parameters in distinguishing subclinical keratoconus (SKC) from normal eyes.
Methods This prospective study was conducted on 73 SKC and 69 normal eyes.
Subclinical keratoconus eyes were defined as corneas with no clinical evidence of keratoconus and suspicious tomographic and tomographic features.
Following a complete ophthalmic examination, topographic and tomographic corneal assessment via Pentacam HR, and corneal biomechanical evaluation utilizing Corvis ST were done.
Results Subclinical keratoconus eyes presented significantly higher Deformation Amplitude (DA) ratio, Tomographic Biomechanical Index (TBI), and Corvis Biomechanical Index (CBI) rates than the control group.
Conversely, Ambrósio Relational Thickness to the Horizontal profile (ARTh), and Stiffness Parameter at the first Applanation (SPA1) showed significantly lower rates in SKC eyes.
In diagnosing SKC from normal eyes, TBI (AUC: 0.
858, Cut-off value: > 0.
33, Youden index: 0.
55), ARTh (AUC: 0.
813, Cut-off value: ≤ 488.
1, Youden index: 0.
58), and CBI (AUC: 0.
804, Cut-off value: > 0.
47, Youden index: 0.
49) appeared as good indicators.
Conclusions Integrated Corvis ST parameters could be valuable in distinguishing SKC eyes from normal ones.

Related Results

Corneal densitometry analysis in patients diagnosed with keratoconus
Corneal densitometry analysis in patients diagnosed with keratoconus
AbstractPurposeThe purpose of this study is to carry out a comparative study of corneal densitometry (COD) using Pentacam HR in two groups of patients. A control group of normal ey...
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Abstract Background To compare the corneal deformation response between patients with keratoconus and healthy subjects and to identify potential characteristics associated...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore to avoid possib...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore, to avoid possi...
Predictive model for early diagnosis of keratoconus
Predictive model for early diagnosis of keratoconus
Abstract Background To describe the topographic, pachymetric and aberrometry characteristics in patients with keratoconus, subclinical keratoconus/forme fruste and normal c...

Back to Top