Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment
View through CrossRef
Abstract
Inter-channel mis-synchronisation can be a limiting factor
to the time resolution of high performance timing detectors with
multiple readout channels and independent electronics units. In
these systems, time calibration methods employed must be able to
efficiently correct for minimal mis-synchronisation between channels
and achieve the best detector performance. We present an iterative
time calibration method based on Markov Chains, suitable for
detector systems with multiple readout channels. Starting from
correlated hit pairs alone, and without requiring an external
reference time measurement, the method solves for fixed per-channel
offsets, with precision limited only by the intrinsic single-channel
resolution. A mathematical proof that the method is able to find the
correct time offsets to be assigned to each detector channel in
order to achieve inter-channel synchronisation is given, and it is
shown that the number of iterations to reach convergence within the
desired precision is controllable with a single parameter. Numerical
studies are used to confirm unbiased recovery of true
offsets. Finally, the application of the calibration method to the
Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF)
detector at the upgraded T2K near detector (ND280) shows good
improvement in overall timing resolution, demonstrating the
effectiveness in a real-world scenario and scalability.
IOP Publishing
S. Abe
H. Alarakia-Charles
I. Alekseev
C. Alt
T. Arai
T. Arihara
S. Arimoto
A.M. Artikov
Y. Awataguchi
N. Babu
V. Baranov
G. Barr
D. Barrow
L. Bartoszek
L. Bernardi
L. Berns
S. Bhattacharjee
A.V. Boikov
A. Blanchet
A. Blondel
A. Bonnemaison
S. Bordoni
M.H. Bui
T.H. Bui
F. Cadoux
S. Cap
A. Cauchois
J. Chakrani
P.S. Chong
A. Chvirova
P. Collard
M. Danilov
C. Davis
V. Davouloury
Yu.I. Davydov
A. Dergacheva
C. Domangue
D. Douqa
T.A. Doyle
O. Drapier
A. Eguchi
J. Elias
G. Erofeev
Y. Favre
D. Fedorova
S. Fedotov
D. Ferlewicz
Y. Fujii
R. Fujita
Y. Furui
F. Gastaldi
A. Gendotti
A. Germer
L. Giannessi
C. Giganti
V. Glagolev
R. Guillaumat
G. Ha
N.C. Hastings
I. Heitkamp
J. Hu
C. Husi
A.K. Ichikawa
T.H. Ishida
A. Izmaylov
K. Iwamoto
M. Jakkapu
C. Jesús-Valls
J.Y. Ji
P. Jonsson
C.K. Jung
H. Kakuno
V.S. Kasturi
M. Kawaue
P.T. Keener
M. Khabibullin
N.V. Khomutov
A. Khotjantsev
T. Kikawa
H. Kikutani
N.V. Kirichkov
A. Klustová
H. Kobayashi
T. Kobayashi
L. Koch
S. Kodama
A.O. Kolesnikov
M. Kolupanova
A. Korzenev
T. Koto
Y. Kudenko
S. Kuribayashi
T. Kutter
M. Lachat
K. Lachner
M. Lamers James
D. Last
N. Latham
M. Lawe
T.A. Le
D. Leon Silverio
B. Li
W. Li
C. Lin
M. Louzir
T. Lux
K.K. Mahtani
S. Manly
D.A. Martinez Caicedo
N. Mashin
T. Matsubara
C. Mauger
K.S. McFarland
C. McGrew
J. McKean
A. Mefodiev
E. Miller
O. Mineev
A. Minamino
A.L. Moreno
A. Muñoz
T. Nakadaira
K. Nakagiri
T. Nakaya
J. Nanni
L. Nicolas
A.D. Nguyen
D.T. Nguyen
H. Nguyen
V. Nguyen
E. Noah Messomo
T. Nosek
H.M. O'Keeffe
T. Ogawa
W. Okinaga
L. Osu
V. Paolone
G. Pelleriti
L. Pickering
M.A. Ramírez
M. Reh
G. Reina
C. Riccio
S. Roth
A. Rubbia
F. Saadi
K. Sakashita
N. Sallin
S. Samani
F. Sanchez
T. Schefke
C. Schloesser
D. Sgalaberna
A. Shaikovskiy
A. Shvartsman
Y. Shiraishi
N. Shvarev
N. Skrobova
D. Smyczek
M. Smy
A. Speers
D. Svirida
M. Ta
S. Tairafune
M. Tani
H. Tanigawa
A. Teklu
S. Tereshchenko
V.V. Tereshchenko
T. Thaiduc
T. Tsushima
M. Tzanov
Y. Uchida
I.I. Vasilyev
E. Villa
T. Vladisavljevic
D. Wakabayashi
H. Wallace
A. Weber
N. Whitney
C. Wret
Y. Xu
Y. Yang
N. Yershov
A.J.P. Yrey
M. Yokoyama
Y. Yoshimoto
X.Y. Zhao
H. Zheng
H. Zhong
T. Zhu
E.D. Zimmerman
M. Zito
Title: Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment
Description:
Abstract
Inter-channel mis-synchronisation can be a limiting factor
to the time resolution of high performance timing detectors with
multiple readout channels and independent electronics units.
In
these systems, time calibration methods employed must be able to
efficiently correct for minimal mis-synchronisation between channels
and achieve the best detector performance.
We present an iterative
time calibration method based on Markov Chains, suitable for
detector systems with multiple readout channels.
Starting from
correlated hit pairs alone, and without requiring an external
reference time measurement, the method solves for fixed per-channel
offsets, with precision limited only by the intrinsic single-channel
resolution.
A mathematical proof that the method is able to find the
correct time offsets to be assigned to each detector channel in
order to achieve inter-channel synchronisation is given, and it is
shown that the number of iterations to reach convergence within the
desired precision is controllable with a single parameter.
Numerical
studies are used to confirm unbiased recovery of true
offsets.
Finally, the application of the calibration method to the
Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF)
detector at the upgraded T2K near detector (ND280) shows good
improvement in overall timing resolution, demonstrating the
effectiveness in a real-world scenario and scalability.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
SuperFGD prototype time resolution studies
SuperFGD prototype time resolution studies
Abstract
The SuperFGD detector will be a novel and important upgrade to the ND280 near detector for both the T2K and Hyper-Kamiokande projects. The main goal of the ...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
When History and Heterogeneity Matter: A Tutorial on the Impact of Markov Model Specifications in the Context of Colorectal Cancer Screening
When History and Heterogeneity Matter: A Tutorial on the Impact of Markov Model Specifications in the Context of Colorectal Cancer Screening
Background
Markov models are used in health research to simulate health care utilization and disease states over time. Health phenomena, however, are complex, a...
How Reliable Are Global Temperature Reconstructions of the Common Era?
How Reliable Are Global Temperature Reconstructions of the Common Era?
Global mean annual temperature has increased by more than 1 °C during the past 150 years, as documented by thermometer measurements. Such observational data are, unfortunately, not...
From T2K to Hyper-Kamiokande : neutrino oscillation analysis and preparation of the time synchronization system
From T2K to Hyper-Kamiokande : neutrino oscillation analysis and preparation of the time synchronization system
De T2K à Hyper-Kamiokande : analyse d’oscillation des neutrinos et préparation du système de synchronisation en temps
Les neutrinos sont les particules du Modèle St...
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Abstract
Objective. Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distrib...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...