Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

First experimental time-of-flight-based proton radiography using low gain avalanche diodes

View through CrossRef
Abstract Objective. Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination. Approach. A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μm and 100 ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.4 MeV protons. Main results. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09% and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT. Significance. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
Title: First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Description:
Abstract Objective.
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body.
Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector.
This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination.
Approach.
A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μm and 100 ps, respectively.
Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET).
With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.
4 MeV protons.
Main results.
Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.
09% and 51.
12%.
Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT.
Significance.
While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT.
Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.

Related Results

Singenetic Avalanche In The Ukrainian Carpathians
Singenetic Avalanche In The Ukrainian Carpathians
Purpose. Study of natural conditions of formation and passage of avalanche situation until the avalanche’s going within the North-Eastern macro-slope of Chorohora and Borzhava land...
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Flight Reservation System
Flight Reservation System
Flight reservation System is a computerized system used to store and retrieve information and conduct transactions related to air travel. The project is aimed at exposing the relev...
Near-field observations of snow-avalanches propagating over a fiber-optic array
Near-field observations of snow-avalanches propagating over a fiber-optic array
<p>We present and evaluate array processing techniques and algorithms for the characterization of snow avalanche signals recorded with Distributed Acoustic Sensing (D...
Dynamics of the deadly snow avalanche of January 18, 2017 at Rigopiano (Central Italy)
Dynamics of the deadly snow avalanche of January 18, 2017 at Rigopiano (Central Italy)
On January 2017, a snow avalanche devastated a Resort-hotel in the municipality of Rigopiano in Abruzzo (Central Italy), unfortunately, burying alive 40 people. In a dramatic rescu...
New flight trajectory optimisation method using genetic algorithms
New flight trajectory optimisation method using genetic algorithms
AbstractThis paper presents a new flight trajectory optimisation method, based on genetic algorithms, where the selected optimisation criterion is the minimisation of the total cos...