Javascript must be enabled to continue!
A Special Technique to Remove a Jammed Cephalic Screw from an Intramedullary Nail: A Case Report
View through CrossRef
Background: The complexity of implant removal is a well-known problem in the field of orthopedics. It is encountered mainly during the removal of plates and screws and understood by the phenomenon of seizing or cold-welding, formerly known in mechanics. In this case study, we describe a complex experience during a gamma nail removal in a 21-year-old male patient, explained by the same phenomenon of seizing or cold-welding. The case is rather unusual and rare, with no similar reports in the literature, and required a special technique of extraction.
Case Report: A 21-year-old male presented to our clinic with a 5-months history of right groin pain radiating to the anterior thigh. The patient was a victim of a car accident three years ago that resulted in right femoral neck and shaft fractures, which were managed by open reduction and internal fixation by a long gamma nail with distal locking. After proper examination, the team decided to remove the implant. There was difficulty loosening the cephalic screw as it was welded to the nail. For this reason, we opted for a technique that involved making a transverse slit at the level of the anterior part of the nail which is in contact with the cephalic screw. It was followed by a hammer blow at the level of the cephalic screw, allowing it to loosen and thus allowing the screws along the femoral nail to be removed successfully.
Conclusion: Our report describes a rare case of a cephalic screw cold-welded/seized into the intramedullary nail, which can be an unexpected and serious complication during intramedullary nail removal. However, our technique described in this case can be an effective way to treat such a complication.
International Journal of Clinical Research
Title: A Special Technique to Remove a Jammed Cephalic Screw from an Intramedullary Nail: A Case Report
Description:
Background: The complexity of implant removal is a well-known problem in the field of orthopedics.
It is encountered mainly during the removal of plates and screws and understood by the phenomenon of seizing or cold-welding, formerly known in mechanics.
In this case study, we describe a complex experience during a gamma nail removal in a 21-year-old male patient, explained by the same phenomenon of seizing or cold-welding.
The case is rather unusual and rare, with no similar reports in the literature, and required a special technique of extraction.
Case Report: A 21-year-old male presented to our clinic with a 5-months history of right groin pain radiating to the anterior thigh.
The patient was a victim of a car accident three years ago that resulted in right femoral neck and shaft fractures, which were managed by open reduction and internal fixation by a long gamma nail with distal locking.
After proper examination, the team decided to remove the implant.
There was difficulty loosening the cephalic screw as it was welded to the nail.
For this reason, we opted for a technique that involved making a transverse slit at the level of the anterior part of the nail which is in contact with the cephalic screw.
It was followed by a hammer blow at the level of the cephalic screw, allowing it to loosen and thus allowing the screws along the femoral nail to be removed successfully.
Conclusion: Our report describes a rare case of a cephalic screw cold-welded/seized into the intramedullary nail, which can be an unexpected and serious complication during intramedullary nail removal.
However, our technique described in this case can be an effective way to treat such a complication.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
since 1950s surgical treatment of extracapsular hip fractures is done using a variety of different implants. Unstable fractures are fractures with lateral wall or posteromedial c...
Two weeks post-operative ultrasound examination of radio-cephalic arteriovenous fistulae to predict maturity in a Chinese population
Two weeks post-operative ultrasound examination of radio-cephalic arteriovenous fistulae to predict maturity in a Chinese population
Aim:
The aim of this study was to assess the accuracy of post-operative ultrasound examination for predicting wrist radio-cephalic arteriovenous fistula maturit...
Hip fixation nail [HFN] /Intramedullary hip screw nail IMHSN management of trochanteric fractures with hip fixation nail- Innovative nail:A prospective pilot study in initial 43 cases
Hip fixation nail [HFN] /Intramedullary hip screw nail IMHSN management of trochanteric fractures with hip fixation nail- Innovative nail:A prospective pilot study in initial 43 cases
Intertrochanteric fractures can be fixed with various implants with surface implants or intramedullary implants. A study was done on Fixation of trochanteric fractures with Hip Fix...
Technique for removing a “cold-welded” interlocking screw from an intramedullary nail in the femur: A case report
Technique for removing a “cold-welded” interlocking screw from an intramedullary nail in the femur: A case report
Rationale:
Removing a bent or broken intramedullary (IM) nail can be challenging even if the nail is intact. Several methods have been described for removing bent or br...
In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation
In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation
Abstract
Background Corrective osteotomies of the proximal phalanx are typically stabilized with plate and screws. Although intramedullary headless screws form an alterna...
Are new implants for patellar fractures reasonable? A biomechanical comparison of intramedullary locking nails versus tension-band osteosynthesis
Are new implants for patellar fractures reasonable? A biomechanical comparison of intramedullary locking nails versus tension-band osteosynthesis
Abstract
Background
Patellar fractures are predominantly treated surgically by open reduction and internal fixation using...

