Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Special Technique to Remove a Jammed Cephalic Screw from an Intramedullary Nail: A Case Report

View through CrossRef
Background:  The complexity of implant removal is a well-known problem in the field of orthopedics. It is encountered mainly during the removal of plates and screws and understood by the phenomenon of seizing or cold-welding, formerly known in mechanics. In this case study, we describe a complex experience during a gamma nail removal in a 21-year-old male patient, explained by the same phenomenon of seizing or cold-welding. The case is rather unusual and rare, with no similar reports in the literature, and required a special technique of extraction. Case Report: A 21-year-old male presented to our clinic with a 5-months history of right groin pain radiating to the anterior thigh. The patient was a victim of a car accident three years ago that resulted in right femoral neck and shaft fractures, which were managed by open reduction and internal fixation by a long gamma nail with distal locking. After proper examination, the team decided to remove the implant. There was difficulty loosening the cephalic screw as it was welded to the nail. For this reason, we opted for a technique that involved making a transverse slit at the level of the anterior part of the nail which is in contact with the cephalic screw. It was followed by a hammer blow at the level of the cephalic screw, allowing it to loosen and thus allowing the screws along the femoral nail to be removed successfully. Conclusion: Our report describes a rare case of a cephalic screw cold-welded/seized into the intramedullary nail, which can be an unexpected and serious complication during intramedullary nail removal. However, our technique described in this case can be an effective way to treat such a complication.
Title: A Special Technique to Remove a Jammed Cephalic Screw from an Intramedullary Nail: A Case Report
Description:
Background:  The complexity of implant removal is a well-known problem in the field of orthopedics.
It is encountered mainly during the removal of plates and screws and understood by the phenomenon of seizing or cold-welding, formerly known in mechanics.
In this case study, we describe a complex experience during a gamma nail removal in a 21-year-old male patient, explained by the same phenomenon of seizing or cold-welding.
The case is rather unusual and rare, with no similar reports in the literature, and required a special technique of extraction.
Case Report: A 21-year-old male presented to our clinic with a 5-months history of right groin pain radiating to the anterior thigh.
The patient was a victim of a car accident three years ago that resulted in right femoral neck and shaft fractures, which were managed by open reduction and internal fixation by a long gamma nail with distal locking.
After proper examination, the team decided to remove the implant.
There was difficulty loosening the cephalic screw as it was welded to the nail.
For this reason, we opted for a technique that involved making a transverse slit at the level of the anterior part of the nail which is in contact with the cephalic screw.
It was followed by a hammer blow at the level of the cephalic screw, allowing it to loosen and thus allowing the screws along the femoral nail to be removed successfully.
Conclusion: Our report describes a rare case of a cephalic screw cold-welded/seized into the intramedullary nail, which can be an unexpected and serious complication during intramedullary nail removal.
However, our technique described in this case can be an effective way to treat such a complication.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract Introduction Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
since 1950s surgical treatment of extracapsular hip fractures is done using a variety of different implants. Unstable fractures are fractures with lateral wall or posteromedial c...
Technique for removing a “cold-welded” interlocking screw from an intramedullary nail in the femur: A case report
Technique for removing a “cold-welded” interlocking screw from an intramedullary nail in the femur: A case report
Rationale: Removing a bent or broken intramedullary (IM) nail can be challenging even if the nail is intact. Several methods have been described for removing bent or br...
In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation
In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation
Abstract Background Corrective osteotomies of the proximal phalanx are typically stabilized with plate and screws. Although intramedullary headless screws form an alterna...

Back to Top