Javascript must be enabled to continue!
Light activated disinfection: an alternative endodontic disinfection strategy
View through CrossRef
AbstractBackground: An improved light activated disinfection technique utilizing a specific photosensitizer formulation, liquid optical‐conduit, oxygen‐carrier and light energy of appropriate wavelength has been introduced recently. This study tested the efficacy of this improved light activated disinfection on ex vivo biofilms of Enterococcus faecalis at two different stages of maturation.Methods: Eighty‐five tooth sections were prepared and endodontic biofilm of E. faecalis were grown within the root canal. In stage 1, conventional light activated disinfection (LAD), chemical disinfectant (sodium hypochlorite) and improved LAD were tested on four‐day‐old (immature) biofilms. In stage 2, conventional LAD, improved LAD and chemomechanical disinfection (alone and in combination with improved LAD) were tested on four‐week‐old (mature) biofilms.Results: Sodium hypochlorite and improved LAD showed the ability to significantly inactivate bacteria in four‐day‐old biofilms when compared to the control and LAD (p < 0.05). Inactivation of bacteria from deeper dentine was higher in improved LAD than sodium hypochlorite. In four‐week‐old biofilms, a combination of chemomechanical disinfection and improved LAD produced significant bacterial killing compared to either chemomechanical disinfection or improved LAD alone.Conclusions: This study highlighted the potential of improved LAD to kill bacteria within dentinal tubules. In combination with chemomechanical preparation, the improved LAD significantly inactivated four‐week‐old biofilm bacteria.
Title: Light activated disinfection: an alternative endodontic disinfection strategy
Description:
AbstractBackground: An improved light activated disinfection technique utilizing a specific photosensitizer formulation, liquid optical‐conduit, oxygen‐carrier and light energy of appropriate wavelength has been introduced recently.
This study tested the efficacy of this improved light activated disinfection on ex vivo biofilms of Enterococcus faecalis at two different stages of maturation.
Methods: Eighty‐five tooth sections were prepared and endodontic biofilm of E.
faecalis were grown within the root canal.
In stage 1, conventional light activated disinfection (LAD), chemical disinfectant (sodium hypochlorite) and improved LAD were tested on four‐day‐old (immature) biofilms.
In stage 2, conventional LAD, improved LAD and chemomechanical disinfection (alone and in combination with improved LAD) were tested on four‐week‐old (mature) biofilms.
Results: Sodium hypochlorite and improved LAD showed the ability to significantly inactivate bacteria in four‐day‐old biofilms when compared to the control and LAD (p < 0.
05).
Inactivation of bacteria from deeper dentine was higher in improved LAD than sodium hypochlorite.
In four‐week‐old biofilms, a combination of chemomechanical disinfection and improved LAD produced significant bacterial killing compared to either chemomechanical disinfection or improved LAD alone.
Conclusions: This study highlighted the potential of improved LAD to kill bacteria within dentinal tubules.
In combination with chemomechanical preparation, the improved LAD significantly inactivated four‐week‐old biofilm bacteria.
Related Results
On the fatigue resistance of endodontic files subjected to electrochemical polishing and an autoclave’s sterilisation cycle
On the fatigue resistance of endodontic files subjected to electrochemical polishing and an autoclave’s sterilisation cycle
Purpose
The purpose of this paper is to improve the surface finish and, therefore, the fatigue resistance of some endodontic files by electrochemical polishing; the influence of ap...
Endodontic Retreatment in Underfilled Root Canal of Maxillary First Molar with Chronic Periapical Abscess: A Case Report
Endodontic Retreatment in Underfilled Root Canal of Maxillary First Molar with Chronic Periapical Abscess: A Case Report
Background:The failure of endodontic treatment commonly caused by imperfect obturation, periodontalperiradicularlesions, untreated root canals, and some other factors. The failure ...
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Mat...
EFFECT OF INTRACANAL CRYOTHERAPY ON THE POST ENDODONTIC PAIN IN TEETH WITH SYMPTOMATIC APICAL PERIODONTITIS
EFFECT OF INTRACANAL CRYOTHERAPY ON THE POST ENDODONTIC PAIN IN TEETH WITH SYMPTOMATIC APICAL PERIODONTITIS
Objectives: To compare the effect of cryotherapy, room temperature saline and no saline as final root canal irrigants on post-endodontic pain in patients with symptomatic apical pe...
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
<table width="645" border="1" cellspacing="0" cellpadding="0"><tbody><tr><td valign="top" width="408"><p> </p><p>Carbon monoxide is a gas ...
CONJUNTURA
CONJUNTURA
<!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Revision>0</o:Revision> <o:TotalTime>0</o:TotalTime> <o:Pages>1</o:Pages> &...
Evaluation of Disinfection Methods and Effects for Handwashing Sinks Contaminated with Pseudomonas aeruginosa
Evaluation of Disinfection Methods and Effects for Handwashing Sinks Contaminated with Pseudomonas aeruginosa
Abstract
Objective
To address the recurrent contamination of handwashing sinks with Pseudomonas aeruginosa (PA) in the Pediatri...
Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study
Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study
Dental impressions is the preliminary step for any procedure and acts as a microbial source leading to contamination to the operator and lab technician. Hence, the disinfection of ...

