Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SU‐FF‐I‐69: Monte‐Carlo Evaluation of the Backscattering Shielding of Two EPIDs

View through CrossRef
Purpose: To evaluate two possible designs to shield the imaging panel from radiation backscattered from objects downstream of the imager. Method and Materials: Two EPID panel variants, panel 1 and panel 2, are prototyped with an in‐house EGSnrc Monte Carlo code module. These panels differ from commercial panels via the addition of composite materials within the detector panel, designed to shield the detection screen from radiation backscattered. No, medium, and strong backscattering materials are simulated via the addition of 10 cm vacuum, water and lead respectively beneath the imager geometry. Poly‐energetic energy deposition kernels for 6 and 18 MV photon beams are calculated using Monte Carlo simulation. The integrated energy is used to evaluate the signal enhancement due to the backscattering. Each kernel is convolved with 5×5, 10×10, 15×15, and 25×25 cm2 fluence profiles to determine the maximum backscatter signal deviation attributable to the added materials as a function of field size. Results: The largest signal enhancements for poly‐energetic irradiations are 2.87% and 3.07% for panel 1 and panel 2 respectively, which occur with the 18 MV incident energy and the lead backscatter. For water, the maximum enhancement is 0.74% and 1.08%. The back‐scatter signal induced deviation decreases with field size. Conclusions: Both prototype imaging panels will reduce the maximum backscatter signal enhancement to <3.1%. For typical clinical field sizes and backscattering materials, the signal enhancement should be <1%. Use of these panels could reduce the backscattering induced uncertainties and improve the reliability of measurements.Conflict of Interest: This work was funded in part by Varian Medical Systems.
Title: SU‐FF‐I‐69: Monte‐Carlo Evaluation of the Backscattering Shielding of Two EPIDs
Description:
Purpose: To evaluate two possible designs to shield the imaging panel from radiation backscattered from objects downstream of the imager.
Method and Materials: Two EPID panel variants, panel 1 and panel 2, are prototyped with an in‐house EGSnrc Monte Carlo code module.
These panels differ from commercial panels via the addition of composite materials within the detector panel, designed to shield the detection screen from radiation backscattered.
No, medium, and strong backscattering materials are simulated via the addition of 10 cm vacuum, water and lead respectively beneath the imager geometry.
Poly‐energetic energy deposition kernels for 6 and 18 MV photon beams are calculated using Monte Carlo simulation.
The integrated energy is used to evaluate the signal enhancement due to the backscattering.
Each kernel is convolved with 5×5, 10×10, 15×15, and 25×25 cm2 fluence profiles to determine the maximum backscatter signal deviation attributable to the added materials as a function of field size.
Results: The largest signal enhancements for poly‐energetic irradiations are 2.
87% and 3.
07% for panel 1 and panel 2 respectively, which occur with the 18 MV incident energy and the lead backscatter.
For water, the maximum enhancement is 0.
74% and 1.
08%.
The back‐scatter signal induced deviation decreases with field size.
Conclusions: Both prototype imaging panels will reduce the maximum backscatter signal enhancement to <3.
1%.
For typical clinical field sizes and backscattering materials, the signal enhancement should be <1%.
Use of these panels could reduce the backscattering induced uncertainties and improve the reliability of measurements.
Conflict of Interest: This work was funded in part by Varian Medical Systems.

Related Results

Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
<b>German Abstract:</b> Monte-Carlo Simulationen spielen eine immer bedeutender werdende Rolle der Finanzwirtschaft, den Sozialwissenschaften und im Risk Management. Mo...
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
For discretely observed barrier options, there exists no closed solution under the Black-Scholes model. Thus, it is often helpful to use Monte Carlo simulations, which are easily a...
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Stock options is one of the derivative products of stocks. The purpose of this study is to analyze the price of European type call options using the antithetic variate method from ...
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Abstract Nowadays, deterministic two-step or Monte Carlo methods are commonly used in core physics calculations. However, with the development of reactor core design, tradi...
Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
Background. Radiation using conventional X‐ray is associated with exposure of radiosensitive organs and typically requires the use of protection. This study is aimed at evaluating ...
Evaluating View Factors Using a Hybrid Monte-Carlo Method
Evaluating View Factors Using a Hybrid Monte-Carlo Method
AbstractThis paper demonstrates that the well-known method for calculating view factors, the Monte Carlo method, combined with ray tracing is not necessarily the most efficient str...
Monte Carlo and quasi-Monte Carlo methods
Monte Carlo and quasi-Monte Carlo methods
Monte Carlo is one of the most versatile and widely used numerical methods. Its convergence rate, O ( N ...
WE‐B‐330A‐01: Shielding Design Workshop: PET/CT
WE‐B‐330A‐01: Shielding Design Workshop: PET/CT
The application of the structural shielding design techniques and goals as outlined in AAPM Task Group Report 108: PET and PET/CT Shielding Requirements Medical Physics (Vol. 33., ...

Back to Top