Javascript must be enabled to continue!
Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
View through CrossRef
Background. Radiation using conventional X‐ray is associated with exposure of radiosensitive organs and typically requires the use of protection. This study is aimed at evaluating the use of bismuth shielding for radiation protection in pediatric pelvic radiography. The effects of the anteroposterior and lateral bismuth shielding were verified by direct measurements at the anatomical position of the gonads. Methods. Radiation doses were measured using optically stimulated luminescence dosimeters (OSLD) and CIRS ATOM Dosimetry Verification Phantoms. Gonad radiographs were acquired using different shields of varying material (lead, bismuth) and thickness and were compared with radiographs obtained without shielding to examine the effects on image quality and optimal reduction of radiation dose. All images were evaluated separately by three pediatric orthopedic practitioners. Results. Results showed that conventional lead gonadal shielding reduces radiation doses by 67.45%, whereas dose reduction using one layer of bismuth shielding is 76.38%. The use of two layers of bismuth shielding reduces the dose by 84.01%. Using three and four layers of bismuth shielding reduces dose by 97.33% and 99.34%, respectively. Progressively lower radiation doses can be achieved by increasing the number of bismuth layers. Images obtained using both one and two layers of bismuth shielding provided adequate diagnostic information, but those obtained using three or four layers of bismuth shielding were inadequate for diagnosis. Conclusions. Bismuth shielding reduces radiation dose exposure providing appropriate protection for children undergoing pelvic radiography. The bismuth shielding material is lighter than lead, making pediatric patients more comfortable and less apt to move, thereby avoiding repeat radiography.
Title: Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
Description:
Background.
Radiation using conventional X‐ray is associated with exposure of radiosensitive organs and typically requires the use of protection.
This study is aimed at evaluating the use of bismuth shielding for radiation protection in pediatric pelvic radiography.
The effects of the anteroposterior and lateral bismuth shielding were verified by direct measurements at the anatomical position of the gonads.
Methods.
Radiation doses were measured using optically stimulated luminescence dosimeters (OSLD) and CIRS ATOM Dosimetry Verification Phantoms.
Gonad radiographs were acquired using different shields of varying material (lead, bismuth) and thickness and were compared with radiographs obtained without shielding to examine the effects on image quality and optimal reduction of radiation dose.
All images were evaluated separately by three pediatric orthopedic practitioners.
Results.
Results showed that conventional lead gonadal shielding reduces radiation doses by 67.
45%, whereas dose reduction using one layer of bismuth shielding is 76.
38%.
The use of two layers of bismuth shielding reduces the dose by 84.
01%.
Using three and four layers of bismuth shielding reduces dose by 97.
33% and 99.
34%, respectively.
Progressively lower radiation doses can be achieved by increasing the number of bismuth layers.
Images obtained using both one and two layers of bismuth shielding provided adequate diagnostic information, but those obtained using three or four layers of bismuth shielding were inadequate for diagnosis.
Conclusions.
Bismuth shielding reduces radiation dose exposure providing appropriate protection for children undergoing pelvic radiography.
The bismuth shielding material is lighter than lead, making pediatric patients more comfortable and less apt to move, thereby avoiding repeat radiography.
Related Results
Bismuth and Bismuth Alloys
Bismuth and Bismuth Alloys
Abstract
The element bismuth, Bi, found in Group 15 (VA) of the Periodic Table, has at no. 83, at wt 208.98. Its valences are +5 and +3. Bismuth is a silvery metal having...
Bismuth and Bismuth Alloys
Bismuth and Bismuth Alloys
Abstract
The element bismuth, Bi, found in Group 15 (VA) of the Periodic Table, has at no. 83, at wt 208.98. Its valences are
\doc...
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
Abstract
Introduction
Vestibulodynia, vulvar pain localized to the vestibule without an identifiable cause, has a multifactorial...
Electrochemical Synthesis of Bismuth Iodide and Bismuth Oxyiodide
Electrochemical Synthesis of Bismuth Iodide and Bismuth Oxyiodide
This study reports the electrochemical synthesis of bismuth iodide and bismuth oxyiodide from acidic baths containing bismuth nitrate, sodium nitrate, iodine and ethylene glycol by...
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Cathlab radiation workers, when performing interventional procedures, are at high risk of the effects of radiation exposure. The risk of radiation exposure is deterministic and sto...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND:
A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements o...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND:
The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implicati...
Synthesis and application of bismuth alkoxide and bismuth titanate
Synthesis and application of bismuth alkoxide and bismuth titanate
Recently, bismuth containing material was used in a number of applications such as sensor, photocatalyst, and electronics. For instance, bismuth titanate sillenite phase performed ...

