Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Corneal Scheimpflug Densitometry in Photorefractive Keratectomy Candidates

View through CrossRef
Purpose: To describe the normative data of corneal densitometry in photorefractive Keratectomy (PRK) candidates by using a Scheimpflug camera. Methods: Five hundred twenty-two eyes of 261 PRK candidates that underwent comprehensive optometric and ophthalmic examinations were enrolled in this study. Corneal densitometry values were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) and displayed in grayscale units (GSU). Results: Of 261 participants, 187 (71.6%) were women. The mean age of the participants was 28.79 ± 5.02 years (range: 21–40 years). The mean entire corneal densitometry was 14.86 ± 2.37 GSU. According to corneal depth, maximum and minimum densitometry values were seen in the anterior (30.28 ± 7.42 GSU) and posterior (9.86 ± 2.08 GSU) layers, respectively (P < 0.001). Based on the annulus over the cornea, the highest and lowest densitometry values were seen in the 10- to 12-mm (21.31 ± 4.26 GSU) and 2- to 6-mm zones (13.26 ± 2.34 GSU), respectively. However, this difference was not seen after 35 years of age. Individuals aged 30 to 35 years showed higher corneal densitometry values compared with subjects aged 20 to 25 years old (P < 0.001). In generalized linear models, the corneal thickness was associated with the densitometry value in the central and posterior corneal layers. There were no significant differences in sex and refractive errors among participants. Conclusions: This study provided normal corneal densitometry data in PRK candidates. Corneal densitometry increased with age until 35 years of age and then decreased thereafter. This finding should be considered in patient selection for PRK and their postoperative examinations.
Title: Corneal Scheimpflug Densitometry in Photorefractive Keratectomy Candidates
Description:
Purpose: To describe the normative data of corneal densitometry in photorefractive Keratectomy (PRK) candidates by using a Scheimpflug camera.
Methods: Five hundred twenty-two eyes of 261 PRK candidates that underwent comprehensive optometric and ophthalmic examinations were enrolled in this study.
Corneal densitometry values were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) and displayed in grayscale units (GSU).
Results: Of 261 participants, 187 (71.
6%) were women.
The mean age of the participants was 28.
79 ± 5.
02 years (range: 21–40 years).
The mean entire corneal densitometry was 14.
86 ± 2.
37 GSU.
According to corneal depth, maximum and minimum densitometry values were seen in the anterior (30.
28 ± 7.
42 GSU) and posterior (9.
86 ± 2.
08 GSU) layers, respectively (P < 0.
001).
Based on the annulus over the cornea, the highest and lowest densitometry values were seen in the 10- to 12-mm (21.
31 ± 4.
26 GSU) and 2- to 6-mm zones (13.
26 ± 2.
34 GSU), respectively.
However, this difference was not seen after 35 years of age.
Individuals aged 30 to 35 years showed higher corneal densitometry values compared with subjects aged 20 to 25 years old (P < 0.
001).
In generalized linear models, the corneal thickness was associated with the densitometry value in the central and posterior corneal layers.
There were no significant differences in sex and refractive errors among participants.
Conclusions: This study provided normal corneal densitometry data in PRK candidates.
Corneal densitometry increased with age until 35 years of age and then decreased thereafter.
This finding should be considered in patient selection for PRK and their postoperative examinations.

Related Results

Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Corneal densitometry analysis in patients diagnosed with keratoconus
Corneal densitometry analysis in patients diagnosed with keratoconus
AbstractPurposeThe purpose of this study is to carry out a comparative study of corneal densitometry (COD) using Pentacam HR in two groups of patients. A control group of normal ey...
Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia
Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia
AIM: To observe the effects of femtosecond laser-assisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking (FS-LASIK Xtra) on corneal densitomet...
Comparative Analysis of Corneal Densitometry Changes Following Standard Versus Accelerated Corneal Cross-Linking Protocol
Comparative Analysis of Corneal Densitometry Changes Following Standard Versus Accelerated Corneal Cross-Linking Protocol
Background and Objectives: The aim of this study is to evaluate and compare changes in corneal densitometry after standard (30 min exposure time of 3 mW/cm2 UVA) and accelerated (1...
Diagnostic value of corneal optical densitometry in keratoconus
Diagnostic value of corneal optical densitometry in keratoconus
Abstract Purpose To investigate the clinical significance of the correlation between optical densitometry and both biomechanical and morphological parameters in keratoconu...
Novel system for measuring the scattering of the cornea and the lens
Novel system for measuring the scattering of the cornea and the lens
Spatial vision features play a key role in human vision quality, which in turn depends on the retinal image quality and posterior neural processing. The retinal image is affected b...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...

Back to Top