Javascript must be enabled to continue!
Comparative Analysis of Corneal Densitometry Changes Following Standard Versus Accelerated Corneal Cross-Linking Protocol
View through CrossRef
Background and Objectives: The aim of this study is to evaluate and compare changes in corneal densitometry after standard (30 min exposure time of 3 mW/cm2 UVA) and accelerated (10 min exposure time of 9 mW/cm2 UVA) protocols of corneal cross-linking (CXL) in patients with progressive keratoconus. Materials and Methods: This study included a total of 38 eyes of 38 patients divided into two equal-sized subgroups. CXL was performed in one group according to the standard epithelium-off protocol (30 min, 3 mW/cm2 UVA) and in the other group according to an accelerated epithelium-off protocol (10 min, 9 mW/cm2 UVA). Scheimpflug imaging was used to evaluate corneal densitometry in the anterior, central, and posterior corneal layers in three concentric zones (0–2 mm, 2–6 mm, and 6–10 mm) at baseline and 1, 3, and 9 months after surgery. Results: This study included 38 patients divided into two subgroups of 19. One group of patients underwent standard and the other accelerated CXL protocol. Participants in the accelerated group were significantly older (p < 0.001). 9 months after CXL treatment, the accelerated group showed higher central and posterior corneal densitometry values, but, after adjusting for age and baseline values, ANCOVA analysis revealed no significant intergroup differences. Both protocols led to overall reductions in corneal densitometry over time. Conclusions: Both the standard and accelerated CXL protocols induce transient corneal haze, which can be objectified by increased corneal densitometry values in first three months post-CXL. The dynamics of the onset and recovery of postoperative corneal haze are comparable and similar in both protocols.
Title: Comparative Analysis of Corneal Densitometry Changes Following Standard Versus Accelerated Corneal Cross-Linking Protocol
Description:
Background and Objectives: The aim of this study is to evaluate and compare changes in corneal densitometry after standard (30 min exposure time of 3 mW/cm2 UVA) and accelerated (10 min exposure time of 9 mW/cm2 UVA) protocols of corneal cross-linking (CXL) in patients with progressive keratoconus.
Materials and Methods: This study included a total of 38 eyes of 38 patients divided into two equal-sized subgroups.
CXL was performed in one group according to the standard epithelium-off protocol (30 min, 3 mW/cm2 UVA) and in the other group according to an accelerated epithelium-off protocol (10 min, 9 mW/cm2 UVA).
Scheimpflug imaging was used to evaluate corneal densitometry in the anterior, central, and posterior corneal layers in three concentric zones (0–2 mm, 2–6 mm, and 6–10 mm) at baseline and 1, 3, and 9 months after surgery.
Results: This study included 38 patients divided into two subgroups of 19.
One group of patients underwent standard and the other accelerated CXL protocol.
Participants in the accelerated group were significantly older (p < 0.
001).
9 months after CXL treatment, the accelerated group showed higher central and posterior corneal densitometry values, but, after adjusting for age and baseline values, ANCOVA analysis revealed no significant intergroup differences.
Both protocols led to overall reductions in corneal densitometry over time.
Conclusions: Both the standard and accelerated CXL protocols induce transient corneal haze, which can be objectified by increased corneal densitometry values in first three months post-CXL.
The dynamics of the onset and recovery of postoperative corneal haze are comparable and similar in both protocols.
Related Results
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Diagnostic value of corneal optical densitometry in keratoconus
Diagnostic value of corneal optical densitometry in keratoconus
Abstract
Purpose
To investigate the clinical significance of the correlation between optical densitometry and both biomechanical and morphological parameters in keratoconu...
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
Background: full thickness corneal transplantation or penetrating keratoplasty (PK) is the only surgical method to manage outcomes of
inflammatory diseases of the anterior eye cham...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Comparison of corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus
Comparison of corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus
AIM: To evaluate the differences in corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus.
METHODS: In our prospective clini...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Repeatability and reproducibility of Keratograph 5M corneal topography
Repeatability and reproducibility of Keratograph 5M corneal topography
Background
Corneal topography is an important diagnostic tool and highly repeatable and reproducible topographic devices are essential in eye care practice. Placido ...

