Javascript must be enabled to continue!
Effect of storage tank material and maintenance on household water quality
View through CrossRef
This study investigated water quality of household water storage tanks in Tiquipaya, Bolivia. Tank age has little effect on water quality. Storage tanks cleaned three or more times per year had statistically less Escherichia coli and turbidity than tanks cleaned less frequently (p = 0.10 and p = 0.06, respectively). There was a statistically significant difference between E. coli counts in tanks cleaned three or more times per year compared with storage tanks cleaned less than once per year (p = 0.01). Polyethylene tanks had statistically higher E. coli counts than fiber cement and fiberglass tanks (p = 0.10 and p = 0.17, respectively). Water temperatures reached their highest levels (34°C) in a black polyethylene tank and temperatures of 20 and 23°C in fiberglass and fiber cement tanks, respectively. Statistically significant increases in total coliforms and E. coli associated with an increase in temperature and a loss of chlorine residual were documented as water traveled from the treatment plant, through the distribution system, and into household cisterns and storage tanks (p values ranged from 0.02 to 0.05).
Title: Effect of storage tank material and maintenance on household water quality
Description:
This study investigated water quality of household water storage tanks in Tiquipaya, Bolivia.
Tank age has little effect on water quality.
Storage tanks cleaned three or more times per year had statistically less Escherichia coli and turbidity than tanks cleaned less frequently (p = 0.
10 and p = 0.
06, respectively).
There was a statistically significant difference between E.
coli counts in tanks cleaned three or more times per year compared with storage tanks cleaned less than once per year (p = 0.
01).
Polyethylene tanks had statistically higher E.
coli counts than fiber cement and fiberglass tanks (p = 0.
10 and p = 0.
17, respectively).
Water temperatures reached their highest levels (34°C) in a black polyethylene tank and temperatures of 20 and 23°C in fiberglass and fiber cement tanks, respectively.
Statistically significant increases in total coliforms and E.
coli associated with an increase in temperature and a loss of chlorine residual were documented as water traveled from the treatment plant, through the distribution system, and into household cisterns and storage tanks (p values ranged from 0.
02 to 0.
05).
Related Results
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Structural damage detection of elevated circular water tank and its supporting system using geodetic techniques
Structural damage detection of elevated circular water tank and its supporting system using geodetic techniques
Water is the main source of daily life for everyone and everywhere in the world. Sufficient water distribution depends on the place and design of water tank in certain areas. Water...
Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler
Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler
Employees who work in offices absolutely need water, for example to wash hands, to defecate, or other household needs. Water availability must be a concern of managers. But in fact...
PERANCANGAN SISTEM PLAMBING PADA BANGUNAN WISMA MESS SEPOLWAN CIPUTAT
PERANCANGAN SISTEM PLAMBING PADA BANGUNAN WISMA MESS SEPOLWAN CIPUTAT
The construction of high-rise buildings in big cities is currently increasing rapidly, before the building is built, it is necessary to plan a plumbing system to meet the needs of ...
Dynamics Modeling and Lateral Stability of Tank Transport Vehicles
Dynamics Modeling and Lateral Stability of Tank Transport Vehicles
<div class="section abstract"><div class="htmlview paragraph">In this paper, the equivalent elliptic gauge pendulum model of liquid sloshing in tank is established, the...
Flow Simulation and Storage Assessment in an Ungauged Irrigation Tank Cascade System Using the SWAT Model
Flow Simulation and Storage Assessment in an Ungauged Irrigation Tank Cascade System Using the SWAT Model
In the semi-arid regions of South Asia, tank systems are the major source of irrigation. In India, the Telangana state government has initiated the Mission Kakatiya program to reju...
Cash‐based approaches in humanitarian emergencies: a systematic review
Cash‐based approaches in humanitarian emergencies: a systematic review
This Campbell systematic review examines the effectiveness, efficiency and implementation of cash transfers in humanitarian settings. The review summarises evidence from five studi...