Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler

View through CrossRef
Employees who work in offices absolutely need water, for example to wash hands, to defecate, or other household needs. Water availability must be a concern of managers. But in fact, many officers pay less attention for this. They let a lot of water flows from the tank or reservoir that makes important water resources are wasted. This study aims to regulate the usage of water in office buildings so that water needs for employees are always met. The system was built by three tanks, one tank as the main water source called the central tank and two tanks as a reservoir of water that will be consumed by employees called tank1 and tank2. To measure the water level in the tank, it will use an ultrasonic sensor. If the water in the central tank has reached the minimum capacity length from the surface of the water to the sensor (≥ 20 cm), the tank manager will receives an SMS that indicates the water in the central tank is not available and needs to be refill. Tank 1 and tank 2 are filled automatically by activating the pump and opening the solenoid valve when the water is less than the maximum limit set (> 5 cm). The results showed that the system was able to send an SMS to the tank manager when the water level had reached the minimum limit with an 7.39 seconds of average delivery time. Tank 1 and tank 2 can be returned off when the water level reaches the 5 cm limit. The average success rate of filling water in tank1 was 98.46% and tank2 was 97.32%.
Title: Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler
Description:
Employees who work in offices absolutely need water, for example to wash hands, to defecate, or other household needs.
Water availability must be a concern of managers.
But in fact, many officers pay less attention for this.
They let a lot of water flows from the tank or reservoir that makes important water resources are wasted.
This study aims to regulate the usage of water in office buildings so that water needs for employees are always met.
The system was built by three tanks, one tank as the main water source called the central tank and two tanks as a reservoir of water that will be consumed by employees called tank1 and tank2.
To measure the water level in the tank, it will use an ultrasonic sensor.
If the water in the central tank has reached the minimum capacity length from the surface of the water to the sensor (≥ 20 cm), the tank manager will receives an SMS that indicates the water in the central tank is not available and needs to be refill.
Tank 1 and tank 2 are filled automatically by activating the pump and opening the solenoid valve when the water is less than the maximum limit set (> 5 cm).
The results showed that the system was able to send an SMS to the tank manager when the water level had reached the minimum limit with an 7.
39 seconds of average delivery time.
Tank 1 and tank 2 can be returned off when the water level reaches the 5 cm limit.
The average success rate of filling water in tank1 was 98.
46% and tank2 was 97.
32%.

Related Results

PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
Since 2011, Indonesia has been committed to reducing greenhouse gas emissions, one of which is by implementing green buildings in office buildings. The aim of implementing green bu...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
KECEMASAN SAAT PANDEMI COVID 19: LITERATUR REVIEW Hardiyati, Efri Widianti, Taty Hernawaty Departemen Keperawatan Jiwa Poltekkes Kemenkes Mamuju Sulbar, Universitas Pad...
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...
IDENTIFIKASI DAN KLASIFIKASI ASET INFRASTRUKTUR BANGUNAN GEDUNG DI UNIVERSITAS PALANGKA RAYA
IDENTIFIKASI DAN KLASIFIKASI ASET INFRASTRUKTUR BANGUNAN GEDUNG DI UNIVERSITAS PALANGKA RAYA
Aset infrastruktur bangunan gedung di lingkungan kampus berperan penting sebagai sarana penunjang kegiatan akademik maupun non akademik. Universitas Palangka Raya sebagai penyeleng...
Perancangan Sistem Smart Garage Berbasis IoT dengan Catu Daya Panel Surya dan Estimasi Efisiensi Energi
Perancangan Sistem Smart Garage Berbasis IoT dengan Catu Daya Panel Surya dan Estimasi Efisiensi Energi
Penggunaan sistem otomasi pada rumah tangga semakin berkembang seiring kemajuan teknologi Internet of Things (IoT), salah satunya adalah sistem smart garage yang mampu mengendalika...
Studi Analisis Beban Dorong untuk Gedung Beton Bertulang
Studi Analisis Beban Dorong untuk Gedung Beton Bertulang
Perencanaan struktur bangunan gedung tahan gempa di negara Indonesia menjadi suatu hal yang sangat penting mengingat sebagian besar wilayah Indonesia terletak dalam wilayah gempa d...
PROTOTYPE PINTU AIR BENDUNGAN OTOMATIS BERBASIS MIKROKONTROLER ARDUINO UNO
PROTOTYPE PINTU AIR BENDUNGAN OTOMATIS BERBASIS MIKROKONTROLER ARDUINO UNO
Pintu air bendungan merupakan elemen krusial dalam manajemen sumber daya air untuk mengatur aliran dan tinggi permukaan air. Penelitian ini merancang dan membangun Sistem Pintu Air...

Back to Top