Javascript must be enabled to continue!
Validation of Adapted Dartmouth Operative Conditions Scale for sedation during pediatric esophagogastroduodenoscopy
View through CrossRef
SummaryAimsPediatric esophagogastroduodenoscopy requires deep sedation as it involves stimulation of the airway. Frequency of adverse events is higher with esophagogastroduodenoscopy. Hence, monitoring needs sedation scales like the Dartmouth Operative Condition Scale that identifies safe states of sedation. This study aims at validating the Adapted Dartmouth Operative Condition Scale for sedation rating by pediatricians during pediatric esophagogastroduodenoscopy.MethodsItems in the Dartmouth Operating Conditions Scale were adapted for pediatric esophagogastroduodenoscopy. Videos of 35 procedures were recorded. The recording started 10 min before sedation and continued till recovery. The videos were split into preprocedure videos, intraprocedure videos, and recovery videos, and further split into 30‐s clips. Twenty representative intraprocedure videos clips were selected. Ten raters scored the videos with the Adapted Dartmouth Operating Conditions Scale and modified‐COMFORT score. The Adapted Dartmouth Operating Conditions Scale scoring was repeated after a month. The preprocedure videos, intraprocedure videos, and recovery videos of ten patients (six clips each) were scored by one rater to assess responsiveness.ResultsThe Adapted Dartmouth Operating Conditions Scale detected nonoptimal sedation states including laryngospasm due to undersedated states. It showed fair interrater reliability at timeline‐1 (intraclass correlation coefficient = 0.45) and timeline‐2 (intraclass correlation coefficient = 0.65) but poor intrarater reliability (intraclass correlation coefficient = 0.32). There was significant positive correlation with modified‐COMFORT (Spearman's rank order correlation, r = 0.150). Responsiveness was demonstrated by the difference in the preprocedure videos, intraprocedure videos, and recovery videos scores (F = 126.50).ConclusionThe Adapted Dartmouth Operating Conditions Scale detects nonoptimal sedation states during pediatric‐esophagogastroduodenoscopy. It shows good criterion validity, interrater reliability, and responsiveness. Poor intrarater reliability seen in our study could be due to item ambiguity arising from the mode of training of the raters in the Dartmouth Operating Conditions Scale.
Title: Validation of Adapted Dartmouth Operative Conditions Scale for sedation during pediatric esophagogastroduodenoscopy
Description:
SummaryAimsPediatric esophagogastroduodenoscopy requires deep sedation as it involves stimulation of the airway.
Frequency of adverse events is higher with esophagogastroduodenoscopy.
Hence, monitoring needs sedation scales like the Dartmouth Operative Condition Scale that identifies safe states of sedation.
This study aims at validating the Adapted Dartmouth Operative Condition Scale for sedation rating by pediatricians during pediatric esophagogastroduodenoscopy.
MethodsItems in the Dartmouth Operating Conditions Scale were adapted for pediatric esophagogastroduodenoscopy.
Videos of 35 procedures were recorded.
The recording started 10 min before sedation and continued till recovery.
The videos were split into preprocedure videos, intraprocedure videos, and recovery videos, and further split into 30‐s clips.
Twenty representative intraprocedure videos clips were selected.
Ten raters scored the videos with the Adapted Dartmouth Operating Conditions Scale and modified‐COMFORT score.
The Adapted Dartmouth Operating Conditions Scale scoring was repeated after a month.
The preprocedure videos, intraprocedure videos, and recovery videos of ten patients (six clips each) were scored by one rater to assess responsiveness.
ResultsThe Adapted Dartmouth Operating Conditions Scale detected nonoptimal sedation states including laryngospasm due to undersedated states.
It showed fair interrater reliability at timeline‐1 (intraclass correlation coefficient = 0.
45) and timeline‐2 (intraclass correlation coefficient = 0.
65) but poor intrarater reliability (intraclass correlation coefficient = 0.
32).
There was significant positive correlation with modified‐COMFORT (Spearman's rank order correlation, r = 0.
150).
Responsiveness was demonstrated by the difference in the preprocedure videos, intraprocedure videos, and recovery videos scores (F = 126.
50).
ConclusionThe Adapted Dartmouth Operating Conditions Scale detects nonoptimal sedation states during pediatric‐esophagogastroduodenoscopy.
It shows good criterion validity, interrater reliability, and responsiveness.
Poor intrarater reliability seen in our study could be due to item ambiguity arising from the mode of training of the raters in the Dartmouth Operating Conditions Scale.
Related Results
Evaluating the Need for Pediatric Procedural Sedation Training in Pediatric Critical Care Medicine Fellowship*
Evaluating the Need for Pediatric Procedural Sedation Training in Pediatric Critical Care Medicine Fellowship*
Objectives:
Pediatric procedural sedation has been increasingly performed by pediatric intensivists over the past decade. Pediatric Critical Care Medicine fellowship gu...
Safety of endoscopist-guided sedation in a low-risk collective
Safety of endoscopist-guided sedation in a low-risk collective
Abstract
Introduction Worldwide, gastrointestinal endoscopies are predominantly performed under sedation. National and international guidelines and recommendations contai...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Pharmacodynamic modeling of moderate sedation and rationale for dosing using midazolam, propofol and alfentanil
Pharmacodynamic modeling of moderate sedation and rationale for dosing using midazolam, propofol and alfentanil
Abstract
Purpose:
Regulations have broadened to allow moderate sedation administration for gastrointestinal endoscopy by non-an...
Pharmacodynamic modeling of moderate sedation and rationale for dosing using midazolam, propofol and alfentanil
Pharmacodynamic modeling of moderate sedation and rationale for dosing using midazolam, propofol and alfentanil
Abstract
Purpose:
Regulations have broadened to allow moderate sedation administration for gastrointestinal endoscopy by non-an...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND:
A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements o...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND:
The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implicati...
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
<em><span id="page3R_mcid52" class="markedContent"><span style="left: calc(var(--scale-factor)*125.30px); top: calc(var(--scale-factor)*539.11px); font-size: calc(va...

