Modeling And Simulation of Power Quality and Transformer Performance

View through CrossRef
Power quality disturbances, such as voltage sags, harmonics, and transients, pose significant challenges to electrical power systems, particularly impacting the performance and lifespan of transformers, which are essential components in power distribution networks. Poor power quality leads to inefficient operation, accelerated wear, and increased maintenance costs of transformers. This study aims to develop a model that simulates the effects of these disturbances on transformer performance, with the objectives of analyzing how voltage sags, harmonics, and transients influence transformer efficiency and lifespan, as well as assessing the effectiveness of protective devices in mitigating these effects. The research employs Ansys Maxwell and MATLAB/Simulink to model transformer behaviour under varying power quality conditions, introducing disturbances such as voltage sags and harmonic distortions to simulate real- world scenarios. The study focuses on medium-voltage transformers typically found in industrial and residential systems. The findings reveal that power quality disturbances, particularly voltage sags and harmonics, increase core losses and thermal stress, reducing transformer efficiency. However, transformers equipped with harmonic filters and voltage stabilizers showed improved resilience, maintaining optimal performance and extending operational life, thus reducing maintenance costs. This study provides valuable insights into enhancing transformer resilience and offers solutions for improving the design and protection of transformers in power systems.
Nigerian Journal of Engineering Research, Faculty of Engineering, University of Cross River State
Title: Modeling And Simulation of Power Quality and Transformer Performance
Description:
Power quality disturbances, such as voltage sags, harmonics, and transients, pose significant challenges to electrical power systems, particularly impacting the performance and lifespan of transformers, which are essential components in power distribution networks.
Poor power quality leads to inefficient operation, accelerated wear, and increased maintenance costs of transformers.
This study aims to develop a model that simulates the effects of these disturbances on transformer performance, with the objectives of analyzing how voltage sags, harmonics, and transients influence transformer efficiency and lifespan, as well as assessing the effectiveness of protective devices in mitigating these effects.
The research employs Ansys Maxwell and MATLAB/Simulink to model transformer behaviour under varying power quality conditions, introducing disturbances such as voltage sags and harmonic distortions to simulate real- world scenarios.
The study focuses on medium-voltage transformers typically found in industrial and residential systems.
The findings reveal that power quality disturbances, particularly voltage sags and harmonics, increase core losses and thermal stress, reducing transformer efficiency.
However, transformers equipped with harmonic filters and voltage stabilizers showed improved resilience, maintaining optimal performance and extending operational life, thus reducing maintenance costs.
This study provides valuable insights into enhancing transformer resilience and offers solutions for improving the design and protection of transformers in power systems.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Power transformer is very important in electric power system due to its function to raise or lower the voltage according to its designation. On the power side, the power transforme...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...