Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Flow Characteristics and Anti-Vortex in a Pump Station with Laterally Asymmetric Inflow

View through CrossRef
In a laterally asymmetric intake pumping station, the flow direction in the forebay is not consistent with flow in the intake channel. Thus, the adverse flow patterns, such as bias flow, large-scale vortex and asymmetric flow occur frequently in the forebay and sump. Based on the Reynolds-averaged Navier-Stokes (RANS) equation and the RNG k-ε turbulence model, a recent flow pattern in a laterally asymmetric intake pumping station was numerically simulated and analyzed, and effective vortex elimination measures were proposed. For the original scheme, seriously biased flow combined with large-scale vortices were observed in the forebay and several vortices occurred in the sump. To suppress the clash inflow in the south and north intake channel, the “straight diversion pier + curved wing wall” and “straight diversion pier + curved wing wall + V-shaped diversion pier” were installed separately. The” symmetrical 川-shaped diversion pier” and “symmetrical 川-shaped diversion pier + circular column” was utilized to eliminate the bias flow and large-scale vortices in the forebay. Finally, the “three- sectional diversion pier”, “three- sectional diversion pier + triangle column” and “three- sectional diversion pier + triangle column + straight back baffle” was applied to decrease the vortex and asymmetric flow near the suction pipe of the sump. By attaching the rectification measure schemes in the intake channel and the forebay, the bias flow and large-scale vortex in the forebay were suppressed to varying degrees. The schemes significantly reduced the recirculation coefficient and greatly reduced the recirculation volume. By utilizing the vortex elimination measures in the sump, the vortex and asymmetric flow basically disappeared, the velocity distribution tended to become more uniform, and the flow rate distinction of each pump was smaller. The outcome can be used to provide a reference and basis for the improvement of flow pattern in similar laterally asymmetric intake pump stations.
Title: Flow Characteristics and Anti-Vortex in a Pump Station with Laterally Asymmetric Inflow
Description:
In a laterally asymmetric intake pumping station, the flow direction in the forebay is not consistent with flow in the intake channel.
Thus, the adverse flow patterns, such as bias flow, large-scale vortex and asymmetric flow occur frequently in the forebay and sump.
Based on the Reynolds-averaged Navier-Stokes (RANS) equation and the RNG k-ε turbulence model, a recent flow pattern in a laterally asymmetric intake pumping station was numerically simulated and analyzed, and effective vortex elimination measures were proposed.
For the original scheme, seriously biased flow combined with large-scale vortices were observed in the forebay and several vortices occurred in the sump.
To suppress the clash inflow in the south and north intake channel, the “straight diversion pier + curved wing wall” and “straight diversion pier + curved wing wall + V-shaped diversion pier” were installed separately.
The” symmetrical 川-shaped diversion pier” and “symmetrical 川-shaped diversion pier + circular column” was utilized to eliminate the bias flow and large-scale vortices in the forebay.
Finally, the “three- sectional diversion pier”, “three- sectional diversion pier + triangle column” and “three- sectional diversion pier + triangle column + straight back baffle” was applied to decrease the vortex and asymmetric flow near the suction pipe of the sump.
By attaching the rectification measure schemes in the intake channel and the forebay, the bias flow and large-scale vortex in the forebay were suppressed to varying degrees.
The schemes significantly reduced the recirculation coefficient and greatly reduced the recirculation volume.
By utilizing the vortex elimination measures in the sump, the vortex and asymmetric flow basically disappeared, the velocity distribution tended to become more uniform, and the flow rate distinction of each pump was smaller.
The outcome can be used to provide a reference and basis for the improvement of flow pattern in similar laterally asymmetric intake pump stations.

Related Results

Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Stability and dynamics of geophysical neutral vortices
Stability and dynamics of geophysical neutral vortices
(English) Mesoscale and submesoscale vortical structures are ubiquitous in the ocean and atmosphere. Most of these vortices are long-lived with a lifetime of several months. They o...
Keakuratan Prediksi Inflow Waduk Dengan Neraca Air Waduk
Keakuratan Prediksi Inflow Waduk Dengan Neraca Air Waduk
Dalam perhitungan inflow waduk sering digunakan persamaan neraca air waduk yang menggunakan data seri laporan harian operasi waduk, evaporasi dan curah hujan diwaduk, dan lengkung ...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
Dynamic Characteristics and Effect on Thrust of Jet Tail Vortex Ring for Pump Jet Propulsion
Dynamic Characteristics and Effect on Thrust of Jet Tail Vortex Ring for Pump Jet Propulsion
When a pump is propelled by a propeller, the nozzle flooding of the jet wake area will produce a turbulent quasi-sequence structure and have a certain impact on the outflow field s...
Pumping Unit Optimization
Pumping Unit Optimization
Abstract In order to produce available fluids, pump jacks used at surface have been engineered to stroke as slow as 6 (six) strokes per minute (SPM) and as fast a...
Series multi-blood pump with dual activation for pediatric patients with heart failure
Series multi-blood pump with dual activation for pediatric patients with heart failure
Pediatric heart failure (HF), arising from both congenital and acquired disorders, is a serious pathology that affects thousands of children each year. Severe cases of pediatric HF...
420 Vortex formation in the pre-ejection phase in the left ventricle
420 Vortex formation in the pre-ejection phase in the left ventricle
Abstract Funding Acknowledgements Central Norway Regional Health Authority Background/Introduction: ...

Back to Top