Javascript must be enabled to continue!
Methods for improving the accuracy of CIE tristimulus values of object color by calculation Part II: Improvement on measurement wavelength ranges
View through CrossRef
The previous paper (part I) analyzed test errors of the spectrophotometer and their reasons, then systematically investigated the algorithms to reduce measuring bandpass error and intervals error. This paper (part II) focuses on the influence of measurement wavelength ranges and their truncation errors, and some algorithms to overcome the truncation errors. CIE recommends that tristimulus values are calculated over a range of 360–830 nm. However, most spectrophotometers do not meet it. The reduction of measurement range will result in a measurement range error or a truncation error. In this study, five ranges commonly employed in practice are selected for investigating the truncation errors, and three extrapolation methods are used to extend the data to compensate for the measurement range loss. Results are obtained by employing 1301 Munsell color chips under illuminant D
65
and CIE 1964 standard observer. For the standard 1-nm intervals, the narrower the range, the larger the truncation error. For the usual-measured 10-nm intervals, bandpass error and intervals error should be handled at the same time, 380–780 nm Table LWL gives the highest accurate outcomes, which even improve the accuracy of the range 360–750 nm to an acceptable level. Whereas, ranges of 360–700 nm and 400–700 nm still need extrapolation to reduce their truncation errors even with Table LWL. Three extrapolation methods of nearest, linear and second-order all reduce the truncation error, but for different ranges, algorithms and illuminants, the optimal method of extrapolation varies.
Title: Methods for improving the accuracy of CIE tristimulus values of object color by calculation Part II: Improvement on measurement wavelength ranges
Description:
The previous paper (part I) analyzed test errors of the spectrophotometer and their reasons, then systematically investigated the algorithms to reduce measuring bandpass error and intervals error.
This paper (part II) focuses on the influence of measurement wavelength ranges and their truncation errors, and some algorithms to overcome the truncation errors.
CIE recommends that tristimulus values are calculated over a range of 360–830 nm.
However, most spectrophotometers do not meet it.
The reduction of measurement range will result in a measurement range error or a truncation error.
In this study, five ranges commonly employed in practice are selected for investigating the truncation errors, and three extrapolation methods are used to extend the data to compensate for the measurement range loss.
Results are obtained by employing 1301 Munsell color chips under illuminant D
65
and CIE 1964 standard observer.
For the standard 1-nm intervals, the narrower the range, the larger the truncation error.
For the usual-measured 10-nm intervals, bandpass error and intervals error should be handled at the same time, 380–780 nm Table LWL gives the highest accurate outcomes, which even improve the accuracy of the range 360–750 nm to an acceptable level.
Whereas, ranges of 360–700 nm and 400–700 nm still need extrapolation to reduce their truncation errors even with Table LWL.
Three extrapolation methods of nearest, linear and second-order all reduce the truncation error, but for different ranges, algorithms and illuminants, the optimal method of extrapolation varies.
Related Results
Crescimento de feijoeiro sob influência de carvão vegetal e esterco bovino
Crescimento de feijoeiro sob influência de carvão vegetal e esterco bovino
<p align="justify"><span style="color: #000000;"><span style="font-family: 'Times New Roman', serif;"><span><span lang="pt-BR">É indiscutível a import...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
CIE S 014-3:2011 Colorimetry - Part 3: CIE Tristimulus Values
CIE S 014-3:2011 Colorimetry - Part 3: CIE Tristimulus Values
Superseded by Colorimetry - Part 3: CIE Tristimulus Values, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-3:2012(E)/CIE S 014-3/E:2011-\n--\n-Colour stimuli with diffe...
Some recent advances in color science
Some recent advances in color science
Abstract
We will discuss some of main topics in two recent publications on color from the International Commission on Illumination (CIE): CIE 015:2018 and CIE 248:20...
CIE S 014-1:2006 Colorimetry - Part 1: CIE Standard Colorimetric Observers
CIE S 014-1:2006 Colorimetry - Part 1: CIE Standard Colorimetric Observers
Superseded by Colorimetry - Part 1: CIE Standard Colorimetric Observers, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-1:2007(E)/CIE S 014-1/E:2006-\n--\n-This CIE Sta...
ISO/CIE 11664-3:2019(E) Colorimetry ? Part 3: CIE tristimulus values
ISO/CIE 11664-3:2019(E) Colorimetry ? Part 3: CIE tristimulus values
This document was prepared by the International Commission on Illumination (CIE) in cooperation with Technical Committee ISO/TC 274, Light and lighting. This first edition of ISO/C...
CIE S 014-5:2009 Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v', Uniform Chromaticity Scale Diagram
CIE S 014-5:2009 Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v', Uniform Chromaticity Scale Diagram
Superseded by Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v' Uniform Chromaticity Scale Diagram, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-5:2009(E)...
Boja kao izlagački aspekt narativnoga filma
Boja kao izlagački aspekt narativnoga filma
The dissertation, titled Colour as an Expository Aspect of the Narrative Film, explores how color shapes the narrative, aesthetic, and emotional dimensions of film. Analyzing the h...

